1.
Clin Pharmacol Drug Dev ; 7(6): 621-626, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29746726

RESUMO

In this study, the in vitro and in vivo interchangeability between generic candesartan 16 mg and the branded formulation was assessed. The in vitro release of these products was conducted in 3 pH media (1.2, 5.0, and 6.8), and similarity factors (f2 ) were calculated. This bioequivalence study was a randomized, 2-period crossover study that included 42 healthy adult male subjects under fasting conditions with a 9-day washout. The pharmacokinetic (PK) parameters AUC0-last , AUC0-∞ , and Cmax , tmax , and the elimination half-life time were assessed based on the plasma concentrations of candesartan, using a newly developed and validated liquid chromatography-tandem mass spectrometry bioanalytical method with acceptable degrees of linearity, sensitivity, precision, and accuracy. The geometric mean (ng·h/mL) of the AUC0-∞ for the test and brand was 1595.49 and 1620.54, respectively, and the Cmax (ng/mL) was 160.91 and 160.88, respectively. The 90%CIs of geometric mean ratios (test-to-reference ratios) were 98.26%, 98.45%, and 99.86% for AUC0-last , AUC0-∞ , and Cmax respectively. These PK parameters lie within the US Food and Drug Administration- and European Medicines Agency-specified bioequivalence limit (80%-125%). Both products were well tolerated by all the subjects. The tested drug product was bioequivalent to the reference drug and had the same safety profile.


Assuntos
Bloqueadores do Receptor Tipo 1 de Angiotensina II/farmacocinética , Benzimidazóis/farmacocinética , Compostos de Bifenilo/farmacocinética , Medicamentos Genéricos/farmacocinética , Tetrazóis/farmacocinética , Administração Oral , Adulto , Bloqueadores do Receptor Tipo 1 de Angiotensina II/administração & dosagem , Bloqueadores do Receptor Tipo 1 de Angiotensina II/sangue , Área Sob a Curva , Benzimidazóis/administração & dosagem , Benzimidazóis/sangue , Disponibilidade Biológica , Compostos de Bifenilo/administração & dosagem , Compostos de Bifenilo/sangue , Estudos Cross-Over , Liberação Controlada de Fármacos , Medicamentos Genéricos/administração & dosagem , Meia-Vida , Voluntários Saudáveis , Humanos , Masculino , Comprimidos , Tetrazóis/administração & dosagem , Tetrazóis/sangue
2.
Int J Clin Pharmacol Ther ; 54(9): 723-31, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27443664

RESUMO

BACKGROUND: Treatment of neuropathic pain has always been challenging, not only from the pharmaco-therapeutic/toxicological point of view, but also due to the unpredictable pharmacokinetic (PK) variations among different generic formulations of the same drug, which require further dose optimization. OBJECTIVES: This progressive work aims to evaluate the bioequivalence (BE) of a generic product of 150 mg pregabalin capsule (antineuropathic drug) vs. the reference brand drug Lyrica®. METHOD: An LC-MS/MS bioanalytical method was developed and validated according to the International Conference on Harmonization (ICH) guidelines in order to be used for the analysis of pregabalin in plasma. BE of capsules was tested by comparison against the reference brand capsules in accordance with the requirements of the declarations of Helsinki, the current Good Clinical Practice (GCP) Guidelines and the ICH. The resulting data were compared against corresponding pregabalin data published on other human races. RESULTS: The relationship between concentration and peak area ratio was found to be linear within the range 0.096 - 6.068 µg/mL for pregabalin. The correlation coefficient (r) was equal to 0.9983. Statistical comparison of the main PK parameters showed no significant difference between test and reference. The mean Cmax values for test and reference were 4.290 and 4.164 µg/mL, and the mean AUC0-last values were 24.275 h×µg/mL and 23.674 h×µg/mL, respectively. The 90% CIs of geometric mean ratios (test/reference) for pregabalin were 100.34 - 104.78%, 100.34 - 104.70%, and 95.65 - 110.96% for AUC0-last, AUC0-∞, and Cmax, respectively, thus fall within the international specified BE limit (80 - 125%). Both products were well tolerated by all the volunteers and there were no significant differences on physical examination or in vital signs and laboratory tests between groups. All volunteers completed the study and were discharged in good health. CONCLUSION: The tested generic capsules appear to be bioequivalent to the reference brand and are expected to have a similar efficacy and safety profile.


Assuntos
Analgésicos/farmacocinética , Árabes , Medicamentos Genéricos/farmacocinética , Pregabalina/farmacocinética , Adolescente , Adulto , Analgésicos/administração & dosagem , Analgésicos/efeitos adversos , Área Sob a Curva , Cápsulas , Cromatografia Líquida/métodos , Estudos Cross-Over , Medicamentos Genéricos/administração & dosagem , Medicamentos Genéricos/efeitos adversos , Humanos , Pessoa de Meia-Idade , Pregabalina/administração & dosagem , Pregabalina/efeitos adversos , Espectrometria de Massas em Tandem/métodos , Equivalência Terapêutica , Adulto Jovem
3.
Sci Pharm ; 84(3): 536-546, 2016 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-28117319

RESUMO

There is a wide inter-individual response to statin therapy including rosuvastatin calcium (RC), and it has been hypothesized that genetic differences may contribute to these variations. In fact, several studies have shown that pharmacokinetic (PK) parameters for RC are affected by race. The aim of this study is to demonstrate the interchangeability between two generic RC 20 mg film-coated tablets under fasting conditions among Mediterranean Arabs and to compare the pharmacokinetic results with Asian and Caucasian subjects from other studies. A single oral RC 20 mg dose, randomized, open-label, two-way crossover design study was conducted in 30 healthy Mediterranean Arab volunteers. Blood samples were collected prior to dosing and over a 72-h period. Concentrations in plasma were quantified using a validated liquid chromatography tandem mass spectrometry method. Twenty-six volunteers completed the study. Statistical comparison of the main PK parameters showed no significant difference between the generic and branded products. The point estimates (ratios of geometric mean %) were 107.73 (96.57-120.17), 103.61 (94.03-114.16), and 104.23 (94.84-114.54) for peak plasma concentration (Cmax), Area Under the Curve (AUC)0→last, and AUC0→∞, respectively. The 90% confidence intervals were within the pre-defined limits of 80%-125% as specified by the Food and Drug Administration and European Medicines Agency for bioequivalence studies. Both formulations were well-tolerated and no serious adverse events were reported. The PK results (AUC0→last and Cmax) were close to those of the Caucasian subjects. This study showed that the test and reference products met the regulatory criteria for bioequivalence following a 20 mg oral dose of RC under fasting conditions. Both formulations also showed comparable safety results. The PK results of the test and reference in the study subjects fall within the acceptable interval of 80%-125% and they were very close to the results among Caucasians. These PK results may be useful in order to determine the suitable RC dose among Arab Mediterranean patients.

4.
Clin Transl Allergy ; 5: 37, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26561521

RESUMO

BACKGROUND: Montelukast is a leukotriene receptor antagonist. The release of leukotrienes causes narrowing and constricting in the respiratory airways. Blocking the action of these leukotrienes, montelukast can be used for the prophylaxis and treatment of chronic asthma. OBJECTIVE: The aim of this study was to evaluate the interchangeability and comparative effectiveness between a generic and a brand montelukast 10 mg immediate release tablets (Broncast(®) and Singulair(®), respectively) after a single oral dose among Arab Mediterranean volunteers. METHODS: An open-label, randomized two-period crossover bioequivalence design was conducted in 31 healthy male volunteers with a 1 week washout between each study period and under fasting conditions. The plasma drug concentration was assessed by using a previously validated LC MS/MS method. The ratio between the generic and brand of geometric least squares means was reported for both generic and brand products. Moreover, an in vitro dissolution study was conducted on generic and brand tablets using three different pH media, and similarity and non-similarity factors (f2 and f1) were calculated. RESULTS: The used bioanalytical method was found to be linear within the range 6.098-365.855 ng/mL. The correlation coefficient was close to 0.999 during the course of the study validation. Statistical comparison of the main pharmacokinetic parameters showed the inexistence of any significant difference between generic and the brand. The point estimates (ratios of geometric means) were 111.939, 111.711, and 112.169 % for AUC0-24, AUC0-∞, and Cmax, respectively. The 90 % confidence intervals (CIs) were within the pre-defined limits of 80.00-125.00 % as specified by the FDA and EMA for bioequivalence studies. F2 and f1 were higher than 50 and lower than 15, respectively in all selected pH media. CONCLUSION: Broncast(®) immediate release film coated tablets (10 mg/tablet) are bioequivalent to Singulair(®) immediate release film coated tablets (10 mg/tablet), with a comparable safety and efficacy profile. This suggests that these two formulations can be clinically considered interchangeable. The dissolution study suggests that it could be used as premarketing quality control parameter in order to maintain the high quality of the produced product.

5.
Drug Des Devel Ther ; 9: 5315-21, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26451086

RESUMO

BACKGROUND: Montelukast (MT) is a leukotriene D4 antagonist. It is an effective and safe medicine for the prophylaxis and treatment of chronic asthma. It is also used to prevent acute exercise-induced bronchoconstriction and as a symptomatic relief of seasonal allergic rhinitis and perennial allergic rhinitis. OBJECTIVE: The aim of this study was to evaluate the bioequivalence (BE) of two drug products: generic MT 5 mg chewable tablets versus the branded drug Singulair(®) pediatric 5 mg chewable tablets among Mediterranean volunteers. METHODS: An open-label, randomized two-period crossover BE design was conducted in 32 healthy male volunteers with a 9-day washout period between doses and under fasting conditions. The drug concentrations in plasma were quantified by using a newly developed and fully validated liquid chromatography tandem mass spectrometry method, and the pharmacokinetic parameters were calculated using a non-compartmental model. The ratio for generic/branded tablets using geometric least squares means was calculated for both the MT products. RESULTS: The relationship between concentration and peak area ratio was found to be linear within the range 6.098-365.855 ng/mL. The correlation coefficient (R (2)) was always greater than 0.99 during the course of the validation. Statistical comparison of the main pharmacokinetic parameters showed no significant difference between the generic and branded products. The point estimates (ratios of geometric means) were 101.2%, 101.6%, and 98.11% for area under the curve (AUC)0→last, AUC0→inf, and C max, respectively. The 90% confidence intervals were within the predefined limits of 80.00%-125.00% as specified by the US Food and Drug Administration and European Medicines Agency for BE studies. CONCLUSION: Broncast(®) pediatric chewable tablets (5 mg/tablet) are bioequivalent to Singulair(®) pediatric chewable tablets (5 mg/tablet), with a similar safety profile. This suggests that these two formulations can be considered interchangeable in clinical practice.


Assuntos
Acetatos/administração & dosagem , Acetatos/farmacocinética , Cromatografia Líquida , Medicamentos Genéricos/administração & dosagem , Medicamentos Genéricos/farmacocinética , Antagonistas de Leucotrienos/administração & dosagem , Antagonistas de Leucotrienos/farmacocinética , Mastigação , Quinolinas/administração & dosagem , Quinolinas/farmacocinética , Espectrometria de Massas em Tandem , Acetatos/sangue , Acetatos/química , Administração Oral , Adolescente , Adulto , Área Sob a Curva , Química Farmacêutica , Estudos Cross-Over , Ciclopropanos , Medicamentos Genéricos/química , Voluntários Saudáveis , Humanos , Antagonistas de Leucotrienos/sangue , Antagonistas de Leucotrienos/química , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Quinolinas/sangue , Quinolinas/química , Reprodutibilidade dos Testes , Sulfetos , Comprimidos , Equivalência Terapêutica , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...