Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Thorac Cardiovasc Surg ; 90(1): 137-44, 1985 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3874324

RESUMO

Between June 12, 1978, and June 12, 1983, 737 St. Jude Medical valves were implanted in 671 patients (431 males, 240 females) ranging in age from 9 months to 82 years (mean 55 years); 16 of these patients (2.3%) were less than or equal to 15 years and 82 (12.2%) were greater than or equal to 70 years. Associated procedures were performed in 28.2% of the 500 aortic valve replacements, 13.3% of the 105 mitral valve replacements, and 10.6% of the 66 double mitral and aortic valve replacements. Hospital mortality (less than or equal to 30 days) was 3.6% (18/500 patients) for aortic, 4.7% (5/105 patients) for mitral, and 0% for double valve replacement. Only one of these 23 hospital deaths was possibly valve-related. Complete follow-up was achieved during December, 1983, and January, 1984, to provide a minimum follow-up of 6 months. Follow-up has been 100% for a total of 1,619 patient-years, with a mean follow-up of 2 1/2 years. There were 41 late deaths (6.1%): 30 in the aortic group, eight in the mitral group, and three in the double valve replacement group. Fourteen (34.2%) of these late deaths have been considered valve-related. At 5 1/2 years, the actuarial survival rate, hospital mortality excluded, is 91% for aortic, 90% for mitral, and 95% for double valve replacement. Functional improvement of these patients is quite satisfactory: Preoperatively, 60.3% were in Class III or IV of the New York Heart Association, whereas postoperatively, 99.5% of the patients are in Class I or II. As 78 patients (65 aortic, 10 mitral, and three double valve replacement) did not receive anticoagulation therapy for a total period of 84 patient-years, the incidence of valve thrombosis, systemic embolism, and sudden or suspicious deaths in this group was compared with that in a group of 630 patients (including 60 patients from the first group who were given anticoagulants afterwards) subjected to long-term anticoagulation for a total period of 1,535 patient-years. A significantly higher incidence of valve thrombosis and systemic embolism was observed in the absence of anticoagulation. Anticoagulant-related complications occurred in 10 patients, with an incidence of 0.65/100 patient-years. On the basis of this 5 1/2 years of experience, the St. Jude Medical valve appears to be an excellent mechanical prosthesis for cardiac valve replacement, in terms of hemodynamic performance and low thrombogenicity, in patients receiving anticoagulants.


Assuntos
Próteses Valvulares Cardíacas/normas , Adolescente , Adulto , Idoso , Anticoagulantes/uso terapêutico , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Baixo Débito Cardíaco/epidemiologia , Criança , Ponte de Artéria Coronária , Morte Súbita/epidemiologia , Embolia/epidemiologia , Feminino , Seguimentos , Próteses Valvulares Cardíacas/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Complicações Pós-Operatórias , Trombose/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...