Mater Sci Eng C Mater Biol Appl ; 69: 122-7, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27612696

RESUMO

This work describes the development of a new biosensor for methylparaben determination using electrocatalytic properties of hemoglobin in the presence of hydrogen peroxide. The voltammetric oxidation of methylparaben by the proposed biosensor in phosphate buffer (pH=7.0), a physiological pH, was studied and it was confirmed that methylparaben undergoes a one electron-one proton reaction in a diffusion-controlled process. The biosensor was fabricated by carbon paste electrode modified with hemoglobin and multiwalled carbon nanotube. Based on the excellent electrochemical properties of the modified electrode, a sensitive voltammetric method was used for determination of methylparaben within a linear range from 0.1 to 13µmolL(-1) and detection limit of 25nmolL(-1). The developed biosensor possessed accurate and rapid response to methylparaben and showed good sensitivity, stability, and repeatability. Finally, the applicability of the proposed biosensor was verified by methylparaben evaluation in various real samples.


Assuntos
Técnicas Biossensoriais/métodos , Hemoglobinas/química , Parabenos/análise , Técnicas Biossensoriais/economia , Técnicas Eletroquímicas , Eletrodos , Humanos , Peróxido de Hidrogênio/química , Concentração de Íons de Hidrogênio , Limite de Detecção , Microscopia Eletrônica de Varredura , Nanotubos de Carbono/química , Oxirredução , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS