Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sleep ; 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38700932

RESUMO

STUDY OBJECTIVES: Evaluate wrist-placed accelerometry predicted heartrate compared to electrocardiogram (ECG) heartrate in children during sleep. METHODS: Children (n=82, 61% male, 43.9% Black) wore a wrist-placed Apple Watch Series 7 (AWS7) and ActiGraph GT9X during a polysomnogram. 3-Axis accelerometry data was extracted from AWS7 and the GT9X. Accelerometry heartrate estimates were derived from jerk (the rate of acceleration change), computed using the peak magnitude frequency in short time Fourier Transforms of Hilbert transformed jerk computed from acceleration magnitude. Heartrates from ECG traces were estimated from R-R intervals using R-pulse detection. Lin's Concordance Correlation Coefficient (CCC), mean absolute error (MAE) and mean absolute percent error (MAPE) assessed agreement with ECG estimated heartrate. Secondary analyses explored agreement by polysomnography sleep stage and a signal quality metric. RESULTS: The developed scripts are available on Github. For the GT9X, CCC was poor at -0.11 and MAE and MAPE were high at 16.8 (SD=14.2) beats/minute and 20.4% (SD=18.5%). For AWS7, CCC was moderate at 0.61 while MAE and MAPE were lower at 6.4 (SD=9.9) beats/minute and 7.3% (SD=10.3%). Accelerometry estimated heartrate for AWS7 was more closely related to ECG heartrate during N2, N3 and REM sleep than lights on, wake, and N1 and when signal quality was high. These patterns were not evident for the GT9X. CONCLUSIONS: Raw accelerometry data extracted from AWS7, but not the GT9X, can be used to estimate heartrate in children while they sleep. Future work is needed to explore the sources (i.e., hardware, software, etc.) of the GT9X's poor performance.

2.
PLoS One ; 19(3): e0286898, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38551940

RESUMO

The purpose of this study was to evaluate the reliability and validity of the raw accelerometry output from research-grade and consumer wearable devices compared to accelerations produced by a mechanical shaker table. Raw accelerometry data from a total of 40 devices (i.e., n = 10 ActiGraph wGT3X-BT, n = 10 Apple Watch Series 7, n = 10 Garmin Vivoactive 4S, and n = 10 Fitbit Sense) were compared to reference accelerations produced by an orbital shaker table at speeds ranging from 0.6 Hz (4.4 milligravity-mg) to 3.2 Hz (124.7mg). Two-way random effects absolute intraclass correlation coefficients (ICC) tested inter-device reliability. Pearson product moment, Lin's concordance correlation coefficient (CCC), absolute error, mean bias, and equivalence testing were calculated to assess the validity between the raw estimates from the devices and the reference metric. Estimates from Apple, ActiGraph, Garmin, and Fitbit were reliable, with ICCs = 0.99, 0.97, 0.88, and 0.88, respectively. Estimates from ActiGraph, Apple, and Fitbit devices exhibited excellent concordance with the reference CCCs = 0.88, 0.83, and 0.85, respectively, while estimates from Garmin exhibited moderate concordance CCC = 0.59 based on the mean aggregation method. ActiGraph, Apple, and Fitbit produced similar absolute errors = 16.9mg, 21.6mg, and 22.0mg, respectively, while Garmin produced higher absolute error = 32.5mg compared to the reference. ActiGraph produced the lowest mean bias 0.0mg (95%CI = -40.0, 41.0). Equivalence testing revealed raw accelerometry data from all devices were not statistically significantly within the equivalence bounds of the shaker speed. Findings from this study provide evidence that raw accelerometry data from Apple, Garmin, and Fitbit devices can be used to reliably estimate movement; however, no estimates were statistically significantly equivalent to the reference. Future studies could explore device-agnostic and harmonization methods for estimating physical activity using the raw accelerometry signals from the consumer wearables studied herein.


Assuntos
Acelerometria , Dispositivos Eletrônicos Vestíveis , Reprodutibilidade dos Testes , Exercício Físico , Monitores de Aptidão Física
3.
Med Sci Sports Exerc ; 56(2): 370-379, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37707503

RESUMO

INTRODUCTION: This study examined the potential of a device agnostic approach for predicting physical activity from consumer wearable accelerometry compared with a research-grade accelerometry. METHODS: Seventy-five 5- to 12-year-olds (58% male, 63% White) participated in a 60-min protocol. Children wore wrist-placed consumer wearables (Apple Watch Series 7 and Garmin Vivoactive 4) and a research-grade device (ActiGraph GT9X) concurrently with an indirect calorimeter (COSMED K5). Activity intensities (i.e., inactive, light, moderate-to-vigorous physical activity) were estimated via indirect calorimetry (criterion), and the Hildebrand thresholds were applied to the raw accelerometer data from the consumer wearables and research-grade device. Epoch-by-epoch (e.g., weighted sensitivity, specificity) and discrepancy (e.g., mean bias, absolute error) analyses evaluated agreement between accelerometry-derived and criterion estimates. Equivalence testing evaluated the equivalence of estimates produced by the consumer wearables and ActiGraph. RESULTS: Estimates produced by the raw accelerometry data from ActiGraph, Apple, and Garmin produced similar criterion agreement with weighted sensitivity = 68.2% (95% confidence interval (CI), 67.1%-69.3%), 73.0% (95% CI, 71.8%-74.3%), and 66.6% (95% CI, 65.7%-67.5%), respectively, and weighted specificity = 84.4% (95% CI, 83.6%-85.2%), 82.0% (95% CI, 80.6%-83.4%), and 75.3% (95% CI, 74.7%-75.9%), respectively. Apple Watch produced the lowest mean bias (inactive, -4.0 ± 4.5; light activity, 2.1 ± 4.0) and absolute error (inactive, 4.9 ± 3.4; light activity, 3.6 ± 2.7) for inactive and light physical activity minutes. For moderate-to-vigorous physical activity, ActiGraph produced the lowest mean bias (1.0 ± 2.9) and absolute error (2.8 ± 2.4). No ActiGraph and consumer wearable device estimates were statistically significantly equivalent. CONCLUSIONS: Raw accelerometry estimated inactive and light activity from wrist-placed consumer wearables performed similarly to, if not better than, a research-grade device, when compared with indirect calorimetry. This proof-of-concept study highlights the potential of device-agnostic methods for quantifying physical activity intensity via consumer wearables.


Assuntos
Acelerometria , Dispositivos Eletrônicos Vestíveis , Criança , Humanos , Masculino , Feminino , Punho , Exercício Físico , Comportamento Sedentário
4.
Stat Methods Med Res ; 32(11): 2254-2269, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37855203

RESUMO

We develop a functional proportional hazards mixture cure model with scalar and functional covariates measured at the baseline. The mixture cure model, useful in studying populations with a cure fraction of a particular event of interest is extended to functional data. We employ the expectation-maximization algorithm and develop a semiparametric penalized spline-based approach to estimate the dynamic functional coefficients of the incidence and the latency part. The proposed method is computationally efficient and simultaneously incorporates smoothness in the estimated functional coefficients via roughness penalty. Simulation studies illustrate a satisfactory performance of the proposed method in accurately estimating the model parameters and the baseline survival function. Finally, the clinical potential of the model is demonstrated in two real data examples that incorporate rich high-dimensional biomedical signals as functional covariates measured at the baseline and constitute novel domains to apply cure survival models in contemporary medical situations. In particular, we analyze (i) minute-by-minute physical activity data from the National Health And Nutrition Examination Survey 2003-2006 to study the association between diurnal patterns of physical activity at baseline and all cancer mortality through 2019 while adjusting for other biological factors; (ii) the impact of daily functional measures of disease severity collected in the intensive care unit on post intensive care unit recovery and mortality event. Our findings provide novel epidemiological insights into the association between daily patterns of physical activity and cancer mortality. Software implementation and illustration of the proposed estimation method are provided in R.


Assuntos
Modelos Estatísticos , Neoplasias , Humanos , Inquéritos Nutricionais , Modelos de Riscos Proporcionais , Simulação por Computador , Algoritmos , Análise de Sobrevida
5.
Ann Epidemiol ; 86: 110-118.e4, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37625499

RESUMO

PURPOSE: Many chronic diseases have detrimental impact on the physical activity (PA) patterns of older adults. Often such diseases have different degrees of severity in males and females. Quantifying this gender difference would not only enhance our understanding of diseases but would also help design individual-specific PA interventions, thereby improving health outcomes for both genders. METHODS: PA data for 747 participants from round 11 (2021) of the National Health and Aging Trends Study were analyzed. Multilevel functional regression models were used to study gender difference in the effects of chronic diseases on daily PA patterns while adjusting for confounders. RESULTS: Females with dementia (or Alzheimer's disease), hypertension, heart and lung disease had lower PA at different times of day compared to females without these diseases, whereas males with and without these diseases had comparable daily PA. Males with diabetes had higher midnight PA and lower noon PA compared to males without diabetes, while females' PA with and without diabetes were similar. CONCLUSIONS: Our analysis demonstrates that although for most diseases, the daily PA patterns of individuals with the disease are negatively altered compared to healthy individuals, the extent of decline varies by gender and time of day. Designing personalized physical activity interventions considering gender and diurnal PA pattern can potentially improve quality of life across both genders.


Assuntos
Exercício Físico , Qualidade de Vida , Humanos , Masculino , Feminino , Idoso , Fatores Sexuais , Envelhecimento , Doença Crônica
6.
Sleep Health ; 9(4): 417-429, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37391280

RESUMO

GOAL AND AIMS: Evaluate the performance of a sleep scoring algorithm applied to raw accelerometry data collected from research-grade and consumer wearable actigraphy devices against polysomnography. FOCUS METHOD/TECHNOLOGY: Automatic sleep/wake classification using the Sadeh algorithm applied to raw accelerometry data from ActiGraph GT9X Link, Apple Watch Series 7, and Garmin Vivoactive 4. REFERENCE METHOD/TECHNOLOGY: Standard manual PSG sleep scoring. SAMPLE: Fifty children with disrupted sleep (M = 8.5 years, range = 5-12 years, 42% Black, 64% male). DESIGN: Participants underwent to single night lab polysomnography while wearing ActiGraph, Apple, and Garmin devices. CORE ANALYTICS: Discrepancy and epoch-by-epoch analyses for sleep/wake classification (devices vs. polysomnography). ADDITIONAL ANALYTICS AND EXPLORATORY ANALYSES: Equivalence testing for sleep/wake classification (research-grade actigraphy vs. commercial devices). CORE OUTCOMES: Compared to polysomnography, accuracy, sensitivity, and specificity were 85.5, 87.4, and 76.8, respectively, for Actigraph; 83.7, 85.2, and 75.8, respectively, for Garmin; and 84.6, 86.2, and 77.2, respectively, for Apple. The magnitude and trend of bias for total sleep time, sleep efficiency, sleep onset latency, and wake after sleep were similar between the research and consumer wearable devices. IMPORTANT ADDITIONAL OUTCOMES: Equivalence testing indicated that total sleep time and sleep efficiency estimates from the research and consumer wearable devices were statistically significantly equivalent. CORE CONCLUSION: This study demonstrates that raw acceleration data from consumer wearable devices has the potential to be harnessed to predict sleep in children. While further work is needed, this strategy could overcome current limitations related to proprietary algorithms for predicting sleep in consumer wearable devices.


Assuntos
Acelerometria , Sono , Humanos , Masculino , Criança , Feminino , Reprodutibilidade dos Testes , Polissonografia , Actigrafia
7.
Biometrics ; 79(1): 292-303, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-34528237

RESUMO

We develop a new method for variable selection in a nonlinear additive function-on-scalar regression (FOSR) model. Existing methods for variable selection in FOSR have focused on the linear effects of scalar predictors, which can be a restrictive assumption in the presence of multiple continuously measured covariates. We propose a computationally efficient approach for variable selection in existing linear FOSR using functional principal component scores of the functional response and extend this framework to a nonlinear additive function-on-scalar model. The proposed method provides a unified and flexible framework for variable selection in FOSR, allowing nonlinear effects of the covariates. Numerical analysis using simulation study illustrates the advantages of the proposed method over existing variable selection methods in FOSR even when the underlying covariate effects are all linear. The proposed procedure is demonstrated on accelerometer data from the 2003-2004 cohorts of the National Health and Nutrition Examination Survey (NHANES) in understanding the association between diurnal patterns of physical activity and demographic, lifestyle, and health characteristics of the participants.


Assuntos
Dinâmica não Linear , Humanos , Inquéritos Nutricionais , Modelos Lineares , Simulação por Computador
8.
Biostatistics ; 24(3): 539-561, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-36519565

RESUMO

With the advent of continuous health monitoring with wearable devices, users now generate their unique streams of continuous data such as minute-level step counts or heartbeats. Summarizing these streams via scalar summaries often ignores the distributional nature of wearable data and almost unavoidably leads to the loss of critical information. We propose to capture the distributional nature of wearable data via user-specific quantile functions (QF) and use these QFs as predictors in scalar-on-quantile-function-regression (SOQFR). As an alternative approach, we also propose to represent QFs via user-specific L-moments, robust rank-based analogs of traditional moments, and use L-moments as predictors in SOQFR (SOQFR-L). These two approaches provide two mutually consistent interpretations: in terms of quantile levels by SOQFR and in terms of L-moments by SOQFR-L. We also demonstrate how to deal with multi-modal distributional data via Joint and Individual Variation Explained using L-moments. The proposed methods are illustrated in a study of association of digital gait biomarkers with cognitive function in Alzheimers disease. Our analysis shows that the proposed methods demonstrate higher predictive performance and attain much stronger associations with clinical cognitive scales compared to simple distributional summaries.


Assuntos
Doença de Alzheimer , Dispositivos Eletrônicos Vestíveis , Humanos , Doença de Alzheimer/diagnóstico , Marcha , Análise de Dados
9.
Sci Rep ; 12(1): 11558, 2022 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-35798763

RESUMO

Wearable data is a rich source of information that can provide a deeper understanding of links between human behaviors and human health. Existing modelling approaches use wearable data summarized at subject level via scalar summaries in regression, temporal (time-of-day) curves in functional data analysis (FDA), and distributions in distributional data analysis (DDA). We propose to capture temporally local distributional information in wearable data using subject-specific time-by-distribution (TD) data objects. Specifically, we develop scalar on time-by-distribution regression (SOTDR) to model associations between scalar response of interest such as health outcomes or disease status and TD predictors. Additionally, we show that TD data objects can be parsimoniously represented via a collection of time-varying L-moments that capture distributional changes over the time-of-day. The proposed method is applied to the accelerometry study of mild Alzheimer's disease (AD). We found that mild AD is significantly associated with reduced upper quantile levels of physical activity, particularly during morning hours. In-sample cross validation demonstrated that TD predictors attain much stronger associations with clinical cognitive scales of attention, verbal memory, and executive function when compared to predictors summarized via scalar total activity counts, temporal functional curves, and quantile functions. Taken together, the present results suggest that SOTDR analysis provides novel insights into cognitive function and AD.


Assuntos
Doença de Alzheimer , Transtornos Cognitivos , Cognição , Transtornos Cognitivos/psicologia , Função Executiva , Exercício Físico , Humanos , Testes Neuropsicológicos
10.
Atmos Environ (1994) ; 254: 118388, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33841026

RESUMO

In 2020, most countries around the world have observed varying degrees of public lockdown measures to mitigate the transmission of SARS-CoV-2. As an unintended consequence of reduced transportation and industrial activities, air quality has dramatically improved in many major cities around the world. In this paper, we analyze the environmental impact of the lockdown measures on P M 2.5 concentration levels in 48 core-based statistical areas (CBSA) of the United States, during the pre and post-lockdown period of January to June 2020. We model the effect of lockdown on the P M 2.5 concentration in different CBSAs while adjusting for various meteorological factors like temperature, wind-speed, precipitation and snow. Linear mixed effects models and functional regression methods with random intercepts are employed to capture the heterogeneity of the effect across different regions. Our analysis shows there is a statistically significant reduction in levels of P M 2.5 across most of the regions during the lock-down period, although interestingly, this effect is not uniform across all the CBSAs under consideration.

11.
Alzheimers Dement (N Y) ; 7(1): e12131, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33598530

RESUMO

INTRODUCTION: Few studies have explored whether gait measured continuously within a community setting can identify individuals with Alzheimer's disease (AD). This study tests the feasibility of this method to identify individuals at the earliest stage of AD. METHODS: Mild AD (n = 38) and cognitively normal control (CNC; n = 48) participants from the University of Kansas Alzheimer's Disease Center Registry wore a GT3x+ accelerometer continuously for 7 days to assess gait. Penalized logistic regression with repeated five-fold cross-validation followed by adjusted logistic regression was used to identify gait metrics with the highest predictive performance in discriminating mild AD from CNC. RESULTS: Variability in step velocity and cadence had the highest predictive utility in identifying individuals with mild AD. Metrics were also associated with cognitive domains impacted in early AD. DISCUSSION: Continuous gait monitoring may be a scalable method to identify individuals at-risk for developing dementia within large, population-based studies.

12.
Biostatistics ; 21(4): 876-894, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31086969

RESUMO

In a cross-sectional study, adolescent and young adult females were asked to recall the time of menarche, if experienced. Some respondents recalled the date exactly, some recalled only the month or the year of the event, and some were unable to recall anything. We consider estimation of the menarcheal age distribution from this interval-censored data. A complicated interplay between age-at-event and calendar time, together with the evident fact of memory fading with time, makes the censoring informative. We propose a model where the probabilities of various types of recall would depend on the time since menarche. For parametric estimation, we model these probabilities using multinomial regression function. Establishing consistency and asymptotic normality of the parametric maximum likelihood estimator requires a bit of tweaking of the standard asymptotic theory, as the data format varies from case to case. We also provide a non-parametric maximum likelihood estimator, propose a computationally simpler approximation, and establish the consistency of both these estimators under mild conditions. We study the small sample performance of the parametric and non-parametric estimators through Monte Carlo simulations. Moreover, we provide a graphical check of the assumption of the multinomial model for the recall probabilities, which appears to hold for the menarcheal data set. Our analysis shows that the use of the partially recalled part of the data indeed leads to smaller confidence intervals of the survival function.


Assuntos
Estudos Transversais , Adolescente , Distribuição por Idade , Feminino , Humanos , Método de Monte Carlo , Probabilidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...