1.
J Cardiovasc Electrophysiol ; 29(4): 573-583, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29316018

RESUMO

BACKGROUND: The definition of sudden death due to arrhythmia relies on the time interval between onset of symptoms and death. However, not all sudden deaths are due to arrhythmia. In patients with an implantable cardioverter defibrillator (ICD), postmortem device interrogation may help better distinguish the mode of death compared to a time-based definition alone. OBJECTIVE: This study aims to assess the proportion of "sudden" cardiac deaths in patients with an ICD that have confirmed arrhythmia. METHODS: We conducted a literature search for studies using postmortem ICD interrogation and a time-based classification of the mode of death. A modified QUADAS-2 checklist was used to assess risk of bias in individual studies. Outcome data were pooled where sufficient data were available. RESULTS: Our search identified 22 studies undertaken between 1982 and 2015 with 23,600 participants. The pooled results (excluding studies with high risk of bias) suggest that ventricular arrhythmias are present at the time of death in 76% of "sudden" deaths (95% confidence interval [CI] 67-85; range 42-88). CONCLUSION: Postmortem ICD interrogation identifies 24% of "sudden" deaths to be nonarrhythmic. Postmortem device interrogation should be considered in all cases of unexplained sudden cardiac death.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/instrumentação , Processamento de Sinais Assistido por Computador , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Autopsia , Causas de Morte , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
JACC Clin Electrophysiol ; 2(2): 181-192, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29766868

RESUMO

The prevalence of first-degree atrioventricular block in the general population is approximately 4%, and it is associated with an increased risk of atrial fibrillation. Cardiac pacing for any indication in patients with first-degree heart block is associated with worse outcomes compared with patients with normal atrioventricular conduction. Among patients with heart failure, first-degree atrioventricular block is present in anywhere between 15% and 51%. Data from cardiac resynchronization therapy studies have shown that first-degree atrioventricular block is associated with an increased risk of mortality and heart failure hospitalization. Recent studies suggest that optimization of atrioventricular delay in patients with cardiac resynchronization therapy is an important target for therapy; however, the optimal method for atrioventricular resynchronization remains unknown. Understanding the role of first-degree atrioventricular block in the treatment of patients with heart failure will improve medical and device therapy.

5.
Am Heart J ; 152(4): 713.e9-13, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16996845

RESUMO

BACKGROUND: Beta-blockers are effective for the treatment of heart failure, but their mechanism of action is unresolved. Heart rate reduction may be a central mechanism or a troublesome side effect. METHODS: A randomized, double-blind, parallel group study comparing chronic higher-rate (80 pulses per minute) with lower-rate (60 pulses per minute) pacing in pacemaker-dependent patients with symptomatic left ventricular (LV) systolic dysfunction, receiving beta-blockers. Gated radionuclide ventriculography (RNVG) was performed at baseline and after at least 9 months. The primary outcome was change in LV volumes, as a marker of beneficial reverse remodeling, from baseline to follow-up. RESULTS: Forty-nine patients were randomized. Mean age was 74 +/- 6 years and with LV ejection fraction of 26% +/- 9% at baseline. During 14 +/- 13 months of follow-up, 21 patients (43%) died and 25 (51%) completed the study protocol: 12 in the higher-rate and 13 in the lower-rate group. Mean LV end-diastolic (higher rate +20 +/- 104 mL vs lower rate -65 +/- 92 mL, P = .03) and systolic (higher rate +29 +/- 83 mL vs lower rate -60 +/- 74 mL, P = .006) volumes increased with higher-rate versus lower-rate pacing, whereas LV ejection fraction declined (higher rate -4.2% +/- 4.4% vs lower rate +2.2% +/- 5.4%, P = .002). CONCLUSION: Reversal of beta-blocker-induced bradycardia has deleterious effects on ventricular function, suggesting heart rate reduction is an important mediator of their effects. The prognosis of patients with pacemakers and heart failure is poor.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Baixo Débito Cardíaco/fisiopatologia , Baixo Débito Cardíaco/terapia , Estimulação Cardíaca Artificial , Frequência Cardíaca/efeitos dos fármacos , Função Ventricular/efeitos dos fármacos , Antagonistas Adrenérgicos beta/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Bradicardia/induzido quimicamente , Bradicardia/prevenção & controle , Baixo Débito Cardíaco/diagnóstico por imagem , Baixo Débito Cardíaco/mortalidade , Estimulação Cardíaca Artificial/efeitos adversos , Método Duplo-Cego , Seguimentos , Imagem do Acúmulo Cardíaco de Comporta , Humanos , Volume Sistólico