Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 61(8): 1506-1510, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-36883744

RESUMO

OBJECTIVES: Given that SARS-CoV-2 antigen tests will represent a pillar for supporting or surrogating molecular testing in the endemic period, we report here the clinical performance of the new SNIBE Maglumi SARS-CoV-2 antigen fully-automated chemiluminescent immunoassay (MAG-CLIA SARS-CoV-2 Ag). METHODS: The study population consisted of 181 subjects (mean age 61 ± 21 years; 92 females) undergoing coronavirus disease 2019 (COVID-19) testing at the local diagnostic facility, from December 2022 to February 2023. Routine diagnostic practice involved the collection of a double nostril nasopharyngeal swab, analyzed in duplicate with SARS-CoV-2 antigen (MAG-CLIA SARS-CoV-2 Ag) and molecular (Altona Diagnostics RealStar SARS-CoV-2 RT-PCR Kit) tests. RESULTS: A significant Spearman's correlation was found between MAG-CLIA SARS-CoV-2 Ag and mean Ct values of SARS-CoV-2 E and S genes (r=-0.95; p<0.001). In all nasopharyngeal samples, the area under the curve (AUC) of MAG-CLIA SARS-CoV-2 Ag was 0.86 (95% CI, 0.81-0.90), with 0.71 sensitivity and 1.00 specificity at 7 ng/L cut-off, increasing to 0.98 (95% CI, 0.96-1.00) AUC and 0.96 sensitivity (with 0.97 specificity) in high viral load samples. When SARS-CoV-2 N protein concentration was replaced with raw instrumental readings (i.e., relative light units [RLU]), the AUC in all samples increased to 0.94. A RLU value of 945 was associated with 88.4% accuracy, 0.85 sensitivity, 0.95 specificity, 0.77 negative predictive value (NPV) and 0.97 positive predictive value (PPV), respectively. CONCLUSIONS: We found satisfactory analytical performance of MAG-CLIA SARS-CoV-2 Ag, which could be used as surrogate of molecular testing for identifying high viral load samples. Broadening the reportable range of values may generate even better performance.


Assuntos
COVID-19 , SARS-CoV-2 , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , COVID-19/diagnóstico , Testes Imunológicos , Área Sob a Curva , Imunoensaio , Sensibilidade e Especificidade
2.
Clin Chem Lab Med ; 61(7): 1343-1348, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36722026

RESUMO

OBJECTIVES: This study investigated the feasibility and clinical value of using a novel, automated and high-throughput SARS-CoV-2 Interferon Gamma Release Assay (IGRA), combined with total anti-SARS-CoV-2 antibodies assessment, for evaluating the immune response after bivalent BNT162b2 vaccination. METHODS: A cohort of healthcare workers, who already underwent primary vaccination and boosting with monovalent BNT162b2 vaccine, received a booster dose of the new BNT162b2 bivalent formulation. Blood samples were taken immediately before vaccination (T0) and 1 month afterwards (T1). Humoral and cellular immunity were assayed with Roche Elecsys Anti-SARS-CoV-2 and Roche Elecsys IGRA SARS-CoV-2, respectively. RESULTS: The study population consisted of 51 subjects (median age: 43 years; 51% females). Total anti-SARS-CoV-2 antibodies and IGRA SARS-CoV-2 values increased at T1 from 9,050 to 25,000 BAU/mL (p<0.001), and from 0.44 to 0.78 IU/mL (p=0.385), accounting for median increase of 2.0 and 1.6 folds, respectively. Increased T1 values of total anti-SARS-CoV-2 antibodies and IGRA SARS-CoV-2 were recorded in 100% and 68.6% subjects, respectively. In those with baseline values below the median, post-vaccine levels displayed larger increases of 3.3 and 5.1 folds for anti-SARS-CoV-2 total antibodies and IGRA SARS-CoV-2, respectively. The variation of total anti-SARS-CoV-2 antibodies was inversely associated with their T0 values (r=-0.97; p<0.001), whilst that of IGRA SARS-CoV-2 was inversely associated with its T0 value (r=-0.58; p<0.001). No other signifcant associations were found with demographical or clinical variables, including side effects. CONCLUSIONS: The bivalent BNT162b2 vaccine booster enhances humoral and cellular immunity against SARS-CoV-2, especially in recipients with lower baseline biological protection.


Assuntos
Vacina BNT162 , COVID-19 , Feminino , Humanos , Adulto , Masculino , COVID-19/prevenção & controle , SARS-CoV-2 , Vacinação , Imunidade Celular , Anticorpos Antivirais
3.
Diagnosis (Berl) ; 10(2): 187-192, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36656638

RESUMO

OBJECTIVES: Since the external validation of severe acute respiratory syndrome coronavirus 2 antigen rapid diagnostic tests (SARS-CoV-2 RDT-Ags) is a necessary requisite before they can be introduced into routine clinical practice, this study reports the results of a real-world assessment of the clinical performance of the new COVID-VIRO ALL IN device. METHODS: The study population consisted in 165 outpatients (median age: 43 years, range: 14-68 years; 66.1% females) who had paired nasal and nasopharyngeal samples collected upon hospital presentation. The samples were concomitantly tested with the AAZ-LMB COVID-VIRO ALL IN SARS-CoV-2 RDT-Ag and with Cepheid Xpert Xpress SARS-CoV-2 real-time reverse transcription polymerase chain reaction (RT-PCR). RESULTS: The number of subjects with positive RT-PCR results (i.e., mean Ct value <45) was 116 (70.3%), 109 (66.1%) and 86 (52.1%) with mean Ct values <37 and <30, respectively. In all RT-PCR positive samples, COVID-VIRO ALL IN displayed 78.8% agreement, 0.698 sensitivity, 1.000 specificity, 0.583 negative predictive value (NPV) and 1.000 positive predictive value (PPV) compared to RT-PCR. The median Ct value of samples testing positive with COVID-VIRO ALL IN was significantly lower than those testing negative (22.8 vs. 32.2; p<0.001). In samples with high viral load (i.e., Ct value <30), COVID-VIRO ALL IN displayed 92.1% agreement, 0.895 sensitivity, 0.949 specificity, 0.983 NPV and 0.951 PPV compared to RT-PCR. CONCLUSIONS: Although the diagnostic performance of COVID-VIRO ALL IN do not exactly match those of the manufacturer, its high NPV in high viral load samples would enable fast-track and rapid identification of highly contagious subjects.


Assuntos
COVID-19 , SARS-CoV-2 , Feminino , Humanos , Adulto , Masculino , SARS-CoV-2/genética , COVID-19/diagnóstico , Antígenos Virais , Hospitais , Pacientes Ambulatoriais
5.
Clin Chem Lab Med ; 60(6): 930-933, 2022 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-35303764

RESUMO

OBJECTIVES: We provide here an updated analysis of an ongoing serosurveillance study, presenting data on the effect of a third dose of Pfizer/BioNTech BNT162b2 vaccine on serum anti-SARS-CoV-2 IgG antibodies. METHODS: We tested baseline SARS-CoV-2 seronegative healthcare workers undergoing primary vaccination with the mRNA-based COVID-19 Comirnaty vaccine, followed by administration of homologous vaccine booster (third dose). Venous blood was collected before either dose of primary vaccination, at 1, 3 and 6 months afterwards, as well as before and 1 month after receiving the vaccine booster. The serum concentration of anti-SARS-CoV-2 IgG was assayed with DiaSorin Trimeric spike IgG immunoassay. RESULTS: The final study population included 53 SARS-CoV-2 seronegative healthcare workers (median age 46 years; 60% females). A first peak of anti-SARS-CoV-2 spike trimeric IgG values was reached 1 month after completing primary vaccination, after which the levels gradually declined until before receiving the vaccine booster. A second peak of anti-SARS-CoV-2 spike trimeric IgG concentration was observed 1 month after receiving the vaccine booster dose (8,700 kBAU/L), which was 39-fold higher than before receiving the vaccine booster (221 kBAU/L; p<0.001), but was also nearly threefold higher compared to values seen at the first peak (2,990 kBAU/L; p<0.001). The rate of subjects with protective anti-SARS-CoV-2 spike trimeric IgG values (i.e., >264 kBAU/L) increased from 47.2% to 100% after 1 month from vaccine booster. CONCLUSIONS: These results support current policies fostering COVID-19 vaccine boosters to reinforce humoral immunity against SARS-CoV-2.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Vacina BNT162 , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Feminino , Humanos , Imunoglobulina G , Masculino , Pessoa de Meia-Idade
7.
Adv Lab Med ; 3(1): 39-50, 2022 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37359438

RESUMO

Objectives: This article aims to summarize the 6-month variation of a vast array of anti-SARS-CoV-2 antibodies in recipients of BNT162b2 mRNA-based vaccination. Methods: The study population consisted of 84 baseline SARS-CoV-2 seronegative healthcare employees (median age 45 years, 53.6% females), receiving mRNA-based BNT162b2 primary vaccination cycle. Blood was collected before the first and second BNT162b2 vaccine doses, as well as 1, 3 and 6 months afterwards. The serum titers of the following anti-SARS-CoV-2 antibodies were assayed: total anti-RBD (receptor binding domain), anti-spike trimeric IgG, anti-RBD IgG and anti-spike S1 IgA. Results: All antibodies' levels peaked 1 month after vaccination, but then displayed a considerable decrease. The median rates of 6-month decline were -95% for IgG anti-SARS-CoV-2 RBD, -85% for IgG anti-SARS-CoV-2 trimeric spike, -73% for IgA anti-SARS-CoV-2 S1 and -56% for total anti-SARS-CoV-2 RBD antibodies, respectively. The median time of seronegativization was estimated at 579 days for total anti-SARS-CoV-2 RBD antibodies, 271 days for IgG anti-SARS-CoV-2 trimeric spike, 264 days for IgG anti-SARS-CoV-2 RBD and 208 days for IgA anti-SARS-CoV-2 S1, respectively. The rate of seropositive subjects declined from 98-100% at the peak to 50-100% after 6 months. The inter-individual variation of anti-SARS-CoV-2 antibodies reduction at 6 months was 3-44% from the peak. Conclusions: The results of this longitudinal serosurvey demonstrate that the titer of anti-SARS-CoV-2 antibodies declined 6 months after BNT162b2 vaccination, with median time of IgG/IgA seronegativization estimated between 7 and 9 months, thus supporting the opportunity of administering vaccine boosters approximately 5 to 6 months after the last dose of the primary vaccination cycle.

8.
EJIFCC ; 32(2): 216-223, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34421491

RESUMO

BACKGROUND: Due to the large volume of tests needed in a relatively short time for screening and diagnosing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, antigen immunoassays may provide a potential supplement to molecular testing. This study was aimed to assess the clinical preference of DiaSorin LIAISON SARS-CoV-2 Ag chemiluminescence immunoassay. METHODS: An upper respiratory specimen was collected in a series of patients referred to the Laboratory Medicine service of Pederzoli Hospital (Peschiera del Garda, Verona, Italy) for screening or diagnosis of SARS-CoV-2 infection. Nasopharyngeal samples were assayed with DiaSorin LIAISON SARS-CoV-2 Ag test and Altona Diagnostics RealStar® SARS-CoV-2 RT-PCR Kit. RESULTS: The final study population consisted of 421 patients (median age, 48 years; 227 women), 301 (71.5%) with positive result of molecular testing, and 126 (29.9%) with cycle threshold (Ct) values of both E and S genes <29.5, thus reflecting higher infectivity. The area under the curve of DiaSorin LIAISON SARS-CoV-2 Ag test 0.82 (95% CI, 0.79-0.86) for sample positivity and 0.98 for higher sample infectivity (95% CI, 0.97 to 0.99). The optimal cut-off for sample positivity was 82 TCID50/mL (0.78 sensitivity, 0.73 specificity and 77% diagnostic accuracy), whilst that for identifying samples associated with a high infective risk was 106 TCID50/mL (0.94 sensitivity, 0.96 specificity and 95% diagnostic accuracy). CONCLUSION: The performance of this chemiluminescence immunoassay would not permit it to replace molecular testing for diagnosing SARS-CoV-2, but may enable rapid and efficient detection of subjects with high SARS-CoV-2 viral load, who are responsible for the largest proportion of infectious clusters.

10.
Diagnosis (Berl) ; 8(3): 322-326, 2021 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-33554511

RESUMO

OBJECTIVES: Novel point-of-care antigen assays present a promising opportunity for rapid screening of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections. The purpose of this study was the clinical assessment of the new Roche SARS-CoV-2 Rapid Antigen Test. METHODS: The clinical performance of Roche SARS-CoV-2 Rapid Antigen Test was evaluated vs. a reverse transcription polymerase chain reaction (RT-PCR) laboratory-based assay (Seegene AllplexTM2019-nCoV) in nasopharyngeal swabs collected from a series of consecutive patients referred for SARS-CoV-2 diagnostics to the Pederzoli Hospital (Peschiera del Garda, Verona, Italy) over a 2-week period. RESULTS: The final study population consisted of 321 consecutive patients (mean age, 46 years and IQR, 32-56 years; 181 women, 56.4%), with 149/321 (46.4%) positive for SARS-CoV-2 RNA via the Seegene AllplexTM2019-nCoV Assay, and 109/321 (34.0%) positive with Roche SARS-CoV-2 Rapid Antigen Test, respectively. The overall accuracy of Roche SARS-CoV-2 Rapid Antigen Test compared to molecular testing was 86.9%, with 72.5% sensitivity and 99.4% specificity. Progressive decline in performance was observed as cycle threshold (Ct) values of different SARS-CoV-2 gene targets increased. The sensitivity was found to range between 97-100% in clinical samples with Ct values <25, between 50-81% in those with Ct values between 25 and <30, but low as 12-18% in samples with Ct values between 30 and <37. CONCLUSIONS: The clinical performance of Roche SARS-CoV-2 Rapid Antigen Test is excellent in nasopharyngeal swabs with Ct values <25, which makes it a reliable screening test in patients with high viral load. However, mass community screening would require the use of more sensitive techniques.


Assuntos
Antígenos Virais/análise , Teste Sorológico para COVID-19/normas , COVID-19/diagnóstico , COVID-19/virologia , Técnicas de Diagnóstico Molecular/normas , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Adulto , Antígenos Virais/imunologia , COVID-19/imunologia , Teste de Ácido Nucleico para COVID-19/normas , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Nasofaringe/imunologia , Nasofaringe/virologia , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Carga Viral
11.
Adv Lab Med ; 2(3): 409-416, 2021 Aug.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37362410

RESUMO

Objectives: Since commercial SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) antigen rapid detection tests (Ag-RDTs) display broad diagnostic efficiency, this study aimed to evaluate the clinical performance of Fluorecare SARS-CoV-2 Spike Protein Test Kit in a real-life scenario. Methods: The study population consisted of a series of patients undergoing SARS-Cov-2 diagnostic testing at Pederzoli Hospital of Peschiera del Garda (Verona, Italy). A nasopharyngeal swab was collected upon hospital admission and assayed with molecular (Altona Diagnostics RealStar® SARSCoV-2 RT-PCR Kit) and antigen (Fluorecare SARS-CoV-2 Spike Protein Test Kit) tests. Results: The study population consisted of 354 patients (mean age, 47 ± 20 years; 195 women, 55.1%), 223 (65.8%) positive at molecular testing. A significant correlation was found between Fluorecare SARS-CoV-2 Spike Protein Test Kit and Altona (both S and E genes: r=-0.75; p<0.001). The cumulative area under the curve in all nasopharyngeal samples was 0.68. At ≥1.0 S/CO manufacturer's cut-off, the sensitivity, specificity, negative and positive predictive values were 27.5, 99.2, 41.5 and 98.5%, respectively. Considerable improvement of sensitivity was observed as Ct values decreased, becoming 66.7% in samples with mean Ct values <30, 90.5% in those with mean Ct values <25, up to 100% in those with mean Ct values <20. Conclusions: The modest sensitivity and negative predictive value of Fluorecare SARS-CoV-2 Spike Protein Test Kit makes unadvisable to use this assay as surrogate of molecular testing for definitively diagnosing SARS-CoV-2 infection, though its suitable sensitivity at high viral load could make it a reliable screening test for patients with higher infective potential.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...