RESUMO

Sporadically, HAdVs from species HAdV-C are detected in acute respiratory disease outbreaks. To rapidly type these viruses, we designed real-time PCR assays that detect and discriminate between adenovirus types HAdV-C1, -C2, -C5, and -C6. Sixteen clinical isolates from the California Department of Public Health were used to validate the new assays. Type-specific TaqMan real-time PCR assays were designed and used independently to successfully identify 16 representative specimens. The lower limit of detection for our LightCycler singleplex real-time PCR assays were calculated to be 100, 100, 100, and 50 genomic copies per reaction for HAdV-C1, HAdV-C2, HAdV-C5 and HAdV-C6, respectively. The results for the singleplex J.B.A.I.D.S. assays were similar. Our assays did not cross-react with other adenoviruses outside of species HAdV-C, respiratory syncytial virus, influenza, or respiratory disease causing bacteria. These assays have the potential to be useful as diagnostic tools for species HAdV-C infection.


Assuntos
Adenoviridae/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Adenoviridae/genética , Infecções por Adenovirus Humanos/diagnóstico , Adenovírus Humanos/genética , Adenovírus Humanos/isolamento & purificação , Humanos , Limite de Detecção , Dados de Sequência Molecular , Reação em Cadeia da Polimerase em Tempo Real/normas , Sensibilidade e Especificidade
2.
J Clin Microbiol ; 48(4): 1397-403, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20053853

RESUMO

Every year, thousands of basic military trainees in each service of the U.S. Armed Forces experience acute respiratory disease. The majority of this disease burden results from infection with human adenoviruses. We designed single- and multiplex assays that detect and discriminate adenovirus types B3, E4, B7, B11, B14, and B21. A total of 116 oropharyngeal swab specimens obtained from patients at the Naval Health Research Center were used to validate the new assays. Type-specific singleplex assays were designed and used independently to successfully identify 94 representative patient specimens. The lower limits of detection for our singleplex real-time PCR assays were calculated to be 50, 500, 500, 50, 50, and 50 genomic copies per reaction for human adenovirus type B3 (HAdV-B3), HAdV-E4, HAdV-B7, HAdV-B11, HAdV-B14, and HAdV-B21, respectively. These were then multiplexed to increase efficiency and tested against singleplex assays using titrated controls. The HAdV-B3/B11 and HAdV-E4/B7 multiplex assays were as sensitive and specific as they were individually. The HAdV-B14/B21 multiplex assay was not as efficient at detecting HAdV-B14 as the singleplex assay. Interestingly, a statistically significant difference was found between the viral loads of HAdV-B14 and those of HAdV-B3, -E4, -B7, and -B21 (P < 0.001). The assays did not cross-react with other adenoviruses, influenza virus, respiratory syncytial virus, or respiratory disease-causing bacteria. These assays have the potential to be useful as clinical diagnostic tools for the detection of HAdV infection in adult populations.


Assuntos
Infecções por Adenoviridae/virologia , Adenovírus Humanos/classificação , Adenovírus Humanos/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Infecções Respiratórias/virologia , Virologia/métodos , Adenovírus Humanos/genética , Adulto , Genótipo , Humanos , Militares , Orofaringe/virologia , Sensibilidade e Especificidade , Estados Unidos , Carga Viral , Adulto Jovem
3.
PLoS One ; 4(9): e7081, 2009 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-19759905

RESUMO

In 2007, the Centers for Disease Control and Prevention (CDC) reported that Human adenovirus type 14 (HAdV-14) infected 106 military personnel and was responsible for the death of one U.S. soldier at Lackland Air Force Base in Texas. Identification of the responsible adenovirus, which had not previously been seen in North America and for which rapid diagnostic tools were unavailable, required retrospective analysis at reference laboratories. Initial quarantine measures were also reliant on relatively slow traditional PCR analysis at other locations. To address this problem, we developed a real-time PCR assay that detects a 225 base pair sequence in the HAdV-14a hexon gene. Fifty-one oropharyngeal swab specimens from the Naval Health Research Center, San Diego, CA and Advanced Diagnostic Laboratory, Lackland AFB, TX were used to validate the new assay. The described assay detected eight of eight and 19 of 19 confirmed HAdV-14a clinical isolates in two separate cohorts from respiratory disease outbreaks. The real-time PCR assay had a wide dynamic range, detecting from 10(2) to 10(7) copies of genomic DNA per reaction. The assay did not cross-react with other adenoviruses, influenza, respiratory syncytial virus, or common respiratory tract bacteria. The described assay is easy to use, sensitive and specific for HAdV-14a in clinical throat swab specimens, and very rapid since turnaround time is less than four hours to obtain an answer.


Assuntos
Infecções por Adenovirus Humanos/diagnóstico , Infecções por Adenovirus Humanos/virologia , Adenovírus Humanos/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Sequência de Bases , Estudos de Coortes , Surtos de Doenças , Humanos , Dados de Sequência Molecular , RNA Viral/genética , Reprodutibilidade dos Testes , Doenças Respiratórias/diagnóstico , Doenças Respiratórias/virologia , Sensibilidade e Especificidade , Homologia de Sequência do Ácido Nucleico , Fatores de Tempo
4.
Mil Med ; 174(9): 983-90, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19780376

RESUMO

Salmonella enterica subsp. enterica serotypes are leading etiological agents of food-borne gastroenteritis. Traditional identification is laborious and time intensive. Faster molecular methods may allow early identification in contaminated food products. We developed a real-time, fluorescence resonance energy transfer hybridization probe polymerase chain reaction (PCR) assay for S. enterica serotypes on the basis of the exclusive presence of the apeE gene in Salmonella Typhimurium. Assay sensitivity for 12 S. enterica serotypes was as low as 1.87 x 10(2) genomic equivalents per milliliter. PCR efficiency was 94% and the dynamic range was linear over six orders of magnitude from 10(0) to 10(6) copies. The lower limit of detection for 12 different food matrices was between 1.5 x 10(2) and 1.5 x 10(5) CFU/mL without pre-enrichment. When combined with high-throughput automated DNA extraction, 32 food specimens were processed and assayed in less than 2 hours, allowing rapid, specific, sensitive detection of S. enterica serotypes in food products.


Assuntos
Transferência Ressonante de Energia de Fluorescência/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Intoxicação Alimentar por Salmonella/diagnóstico , Salmonella enterica/isolamento & purificação , Sorotipagem/métodos , Animais , DNA Bacteriano/análise , Microbiologia de Alimentos , Carne/microbiologia , Salmonella enterica/genética , Sensibilidade e Especificidade , Verduras/microbiologia