RESUMO
PURPOSE: We conducted a prospective study to evaluate needle displacements between prostate high-dose-rate (HDR) brachytherapy fractions and offer technical recommendations to help prevent displacements from the outset. METHODS AND MATERIALS: Planning computed tomography and verification computed tomography scans were obtained at 1-mm slice thickness and prospectively assessed for interfraction needle movement for each fraction of a 2-fraction HDR prostate boost. For both the planning and verification CTs, distances from each needle tip to the centroid of 3 implanted prostate gold seeds were measured. We determined the mean and range of the displacement distances. RESULTS: Thirty-three consecutive patients (66 fractions, 540 needle-pair positions for a total of 1080 needles) were evaluated for changes in the length between the needle tip and centroid displacement. Overall, only 0.2% of the needles had any change greater than 3.5 mm between the needle tip and centroid. The mean amount of displacement was 0.97 mm, with a standard deviation of 0.76 mm. Among the patients, no fraction had more than 1 needle with a variation greater than 3.0 mm. CONCLUSIONS: Needle displacements in HDR prostate brachytherapy have been reported by numerous institutions using various techniques. We report the first study to demonstrate needle displacement of less than 1 mm on average, and we describe our process of care surrounding the implantation.
Assuntos
Braquiterapia/métodos , Agulhas , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Masculino , Estudos Prospectivos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Tomografia Computadorizada por Raios XRESUMO
This case report of 74-year-old man with trigeminal neuralgia is presented to underscore the importance of evaluating the entire treatment plan, especially when delivering large doses where even a low percentage of the prescription dose can contribute a substantial dose to an unintended target. The patient was treated using the CyberKnife stereotactic radiosurgery system utilizing a nonisocentric beam treatment plan with a 5-mm fixed collimator generating 111 beams to deliver 6000 cGy to the 79% isodose line with a maximum dose of 7594 cGy to the target. Two weeks after treatment the patient's trigeminal neuralgia symptoms resolved; however, the patient developed oral mucositis due to the treatment. This case report reviews the cause of mucositis and makes recommendations on how to prevent unintended targets from receiving treatment.