1.
Appl Opt ; 46(15): 2870-80, 2007 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-17514232

RESUMO

The development of a radiation thermometer calibrated for spectral radiance responsivity using cryogenic, electrical-substitution radiometry to determine the thermodynamic temperatures of the Ag- and Au-freezing temperatures is described. The absolute spectral radiance responsivity of the radiation thermometer is measured in the NIST Spectral Irradiance and Radiance Responsivity Calibrations using Uniform Sources (SIRCUS) facility with a total uncertainty of 0.15% (k=2) and is traceable to the electrical watt, and thus the thermodynamic temperature of any blackbody can be determined by using Planck radiation law and the measured optical power. The thermodynamic temperatures of the Ag- and Au-freezing temperatures are determined to be 1234.956 K (+/-0.110 K) (k=2) and 1337.344 K(+/-0.129 K) (k=2) differing from the International Temperature Scale of 1990 (ITS-90) assignments by 26 mK and 14 mK, respectively, within the stated uncertainties. The temperatures were systematically corrected for the size- of-source effect, the nonlinearity of the preamplifier and the emissivity of the blackbody. The ultimate goal of these thermodynamic temperature measurements is to disseminate temperature scales with lower uncertainties than those of the ITS-90. These results indicate that direct disseminations of thermodynamic temperature scales are possible.

2.
Appl Opt ; 46(1): 25-35, 2007 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-17167550

RESUMO

A new facility for measuring irradiance in the UV was commissioned recently at the National Institute of Standards and Technology (NIST). The facility uses the calculable radiation from the Synchrotron Ultraviolet Radiation Facility as the primary standard. To measure the irradiance from a source under test, an integrating sphere spectrometer-detector system measures both the source under test and the synchrotron radiation sequentially, and the irradiance from the source under test can be determined. In particular, we discuss the calibration of deuterium lamps using this facility from 200 to 400 nm. This facility improves the current NIST UV irradiance scale to a relative measurement uncertainty of 1.2% (k=2).

3.
J Res Natl Inst Stand Technol ; 112(1): 39-51, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-27110453

RESUMO

The successful development of an Optical Technology Division quality system for optical radiation measurement services has provided the opportunity to reconsider the existing calibration procedures to improve quality and reduce costs. We have instituted procedures in our calibration programs to eliminate uninformative repetitive measurements by concentrating our efforts on controlling and understanding the measurement process. The first program in our calibration services to undergo these revisions is described in this paper.

4.
Appl Opt ; 41(28): 5872-8, 2002 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-12371544

RESUMO

The temporal stability of the National Institute of Standards and Technology (NIST) spectral irradiance scale as measured with broadband filter radiometers calibrated for absolute spectral irradiance responsivity is described. The working standard free-electron laser (FEL) lamps and the check standard FEL lamps have been monitored with radiometers in the ultraviolet and the visible wavelength regions. The measurements made with these two radiometers reveal that the NIST spectral irradiance scale as compared with an absolute thermodynamic scale has not changed by more than 1.5% in the visible from 1993 to 1999. Similar measurements in the ultraviolet reveal that the corresponding change is less than 1.5% from 1995 to 1999. Furthermore, a check of the spectral irradiance scale by six different filter radiometers calibrated for absolute spectral irradiance responsivity based on the high-accuracy cryogenic radiometer shows that the agreement between the present scale and the detector-based scale is better than 1.3% throughout the visible to the near-infrared wavelength region. These results validate the assigned spectral irradiance of the widely disseminated NIST or NIST-traceable standard sources.

5.
Appl Opt ; 41(28): 5879-90, 2002 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-12371545

RESUMO

A detector-based spectral irradiance scale has been realized at the National Institute of Standards and Technology (NIST). Unlike the previous NIST spectral irradiance scales, the new scale is generated with filter radiometers calibrated for absolute spectral power responsivity traceable to the NIST high-accuracy cryogenic radiometer instead of with the gold freezing-point blackbody. The calibrated filter radiometers are then used to establish the radiance temperature of a high-temperature blackbody (HTBB) operating near 3,000 K The spectral irradiance of the HTBB is then determined with knowledge of the geometric factors and is used to assign the spectral irradiances of a group of 1,000-W free-electron laser lamps. The detector-based spectral irradiance scale results in the reduction of the uncertainties from the previous source-based spectral irradiance scale by at least a factor of 2 in the ultraviolet and visible wavelength regions. The new detector-based spectral irradiance scale also leads to a reduction in the uncertainties in the shortwave infrared wavelength region by at least a factor of 2-10, depending on the wavelength. Following the establishment of the spectral irradiance scale in the early 1960s, the detector-based spectral irradiance scale represents a fundamental change in the way that the NIST spectral irradiance scale is realized.