Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Anaesthesiol Scand ; 64(7): 953-960, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32236940

RESUMO

BACKGROUND: B-lines as typical artefacts of lung ultrasound are considered as surrogate measurement for extravascular lung water. However, B-lines develop in the sub-pleural space and do not allow assessment of the whole lung. Here, we present data from the first observational multi-centre study focusing on the correlation between a B-lines score and extravascular lung water in critically ill patients suffering from a variety of diseases. PATIENTS AND METHODS: In 184 adult patients, 443 measurements were obtained. B-lines were counted and expressed in a score which was compared to extravascular lung water, measured by single-indicator transpulmonary thermodilution. Appropriate correlation coefficients were calculated and receiver operating characteristics (ROC-) curves were plotted. RESULTS: Overall, B-lines score was correlated with body weight-indexed extravascular lung water characterized by r = .59. The subgroup analysis revealed a correlation coefficient in patients without an infection of r = .44, in those with a pulmonary infection of r = .75 and in those with an abdominal infection of r = .23, respectively. Using ROC-analysis the sensitivity and specificity of B-lines for detecting an increased extravascular lung water (>10 mL/kg) was 63% and 79%, respectively. In patients with a P/F ratio <200 mm Hg, sensitivity and specificity to predict an increased extravascular lung water was 71% and 93%, respectively. CONCLUSIONS: Assessment of B-lines does not accurately reflect actual extravascular lung water. In presence of an impaired oxygenation, B-lines may reliably indicate increased extravascular lung water as cause of the oxygenation disorders.


Assuntos
Água Extravascular Pulmonar/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estado Terminal , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Termodiluição , Adulto Jovem
2.
Ann Thorac Surg ; 76(2): 516-21; discussion 521-2, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12902096

RESUMO

BACKGROUND: To test the hypothesis that bilateral extracorporeal circulation (ECC) (Drew technique) ameliorates the increase in extravascular thermal volume (ETV) observed after conventional cardiopulmonary bypass (CPB) in patients undergoing coronary artery bypass grafting. METHODS: Thirty-four consecutive patients underwent either bilateral ECC (n = 24, additional cannulation of pulmonary artery and left atrium and lungs perfused and ventilated during bypass) or conventional CPB (n = 10, right atrial and aortic cannulation, lungs statically inflated to 4 mbar (0.41 cm H(2)O) with oxygen, 500 mL/min). Determinations of ETV (thermodye dilution technique) and intraoperative fluid balance were made before surgery, at the end of surgery, and 4 hours thereafter. In addition, interleukin (IL)-8, thromboxane B2 (TxB(2)), and endothelin (ET)-1 concentrations were measured in the right atrium and pulmonary vein at specified time points. RESULTS: Comparisons of ETV made at the start of surgery, after aortic declamping, and after termination of ECC, respectively, revealed an increase from 4.8 +/- 0.2 mL/kg (mean +/- SEM) to 6.7 +/- 0.4 mL/kg, and 6.3 +/- 0.3 mL/kg with conventional CPB but ETV remained unchanged at 5.2 +/- 0.3 mL/kg, 5.1 +/- 0.2 mL/kg, and 4.9 +/- 0.3 mL/kg with bilateral ECC. Priming volume (1,580 +/- 10 mL versus 2,213 +/- 77 mL, p < 0.001) and intraoperative fluid balance (+1,955 +/- 233 mL versus +2,654 +/- 210 mL, p < 0.05) were less with conventional CPB. Concentrations of IL-8, TxB(2), and ET-1 were not different between groups. CONCLUSIONS: Despite a significantly greater prime volume and a more positive intraoperative fluid balance, ETV did not change with bilateral ECC but increased with conventional CPB. Thus, using the patient's lungs as an oxygenator during bypass mitigates the increase in extravascular pulmonary fluid.


Assuntos
Ponte Cardiopulmonar/métodos , Ponte de Artéria Coronária/métodos , Água Extravascular Pulmonar/química , Oxigênio/metabolismo , Idoso , Idoso de 80 Anos ou mais , Ponte Cardiopulmonar/mortalidade , Estudos de Casos e Controles , Ponte de Artéria Coronária/mortalidade , Doença das Coronárias/diagnóstico , Doença das Coronárias/mortalidade , Doença das Coronárias/cirurgia , Circulação Extracorpórea , Feminino , Seguimentos , Humanos , Medidas de Volume Pulmonar , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Probabilidade , Estudos Prospectivos , Troca Gasosa Pulmonar , Valores de Referência , Respiração Artificial , Medição de Risco , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...