Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Methods ; 15(39): 5218-5224, 2023 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-37781887

RESUMO

The analysis of individual particles with complex morphologies from light scattering is crucial in disperse systems studies, such as blood cells. Characterization, which assumes determining particle characteristics, has a higher likelihood of succeeding in solving the inverse light-scattering problem if an instrument provides enough light-scattering data. In this study, we demonstrate how we extend the operating angular interval for the 4π Scanning Flow Cytometer (4πSFC), which measures angle-resolved light-scattering profiles (LSPs) of individual particles. The angular interval is extended by additionally measuring light scattering for the backward hemisphere. Currently, the 4πSFC setup uses three lasers, a single optical cell, and three photomultipliers. It enables the measurement of the LSP of individual particles within the angular interval of 10 to 170° for polar angles with integration over azimuth angles, which covers the spatial angle of 98.5% of the 4π angle. We demonstrate the 4πSFC's performance in measuring LSPs from the analysis of polymer beads, mature and spherized erythrocytes, and platelets. The 4πSFC has the potential to be very useful in identifying platelet dimers and granulocytes without labels, characterizing lymphocytes, monocytes, and abnormal erythrocytes.


Assuntos
Plaquetas , Luz , Citometria de Fluxo , Espalhamento de Radiação , Granulócitos
2.
Cytometry A ; 103(9): 736-743, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37306103

RESUMO

Ultraviolet lasers are commonly used in flow cytometry to excite fluorochrome molecules with subsequent measurement of the specific fluorescence of individual cells. In this study, the performance of the ultraviolet light scattering (UVLS) in the analysis of individual particles with flow cytometry has been demonstrated for the first time. The main advantage of the UVLS relates to the improvement of the analysis of submicron particles due to the strong dependence of the scattering efficiency on the wavelength of the incident light. In this work, submicron particles were analyzed using a scanning flow cytometer (SFC) that allows measurements of light scattering in an angle-resolved regime. The measured light-scattering profiles of individual particles were utilized in solution of the inverse light-scattering problem to retrieve the particle characteristics using a global optimization. The standard polystyrene microspheres were successfully characterized from the analysis of UVLS which provided the size and refractive index (RI) of individual beads. We believe that the main application of UVLS relates to the analysis of microparticles in a serum, in particular in the analysis of chylomicrons (CMs). We have demonstrated the performance of the UVLS SFC in the analysis of CMs of a donor. The RI versus size scatterplot of CMs was successfully retrieved from the analysis. The current set-up of the SFC has allowed us to characterize individual CMs starting from the size of 160 nm that provides determination of the CM concentration in a serum with flow cytometry. This feature of the UVLS should help with the analysis of lipid metabolism measuring RI and size map evolution after lipase action.


Assuntos
Micropartículas Derivadas de Células , Raios Ultravioleta , Citometria de Fluxo , Espalhamento de Radiação , Metabolismo dos Lipídeos , Tamanho da Partícula
3.
Cytometry A ; 103(9): 712-722, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37195007

RESUMO

Methods for measuring erythrocyte age distribution are not available as a simple analytical tool. Most of them utilize the fluorescence or radioactive isotopes labeling to construct the age distribution and support physicians with aging indices of donor's erythrocytes. The age distribution of erythrocyte may be a useful snapshot of patient state over 120-days period of life. Previously, we introduced the enhanced assay of erythrocytes with measurement of 48 indices in four categories: concentration/content, morphology, aging and function (10.1002/cyto.a.24554). The aging category was formed by the indices based on the evaluation of the derived age of individual cells. The derived age does not exactly mean the real age of erythrocytes and its evaluation utilizes changes of cellular morphology during a lifespan. In this study, we are introducing the improved methodological approach that allows us to retrieve the derived age of individual erythrocytes, to construct the aging distribution, and to reform the aging category consisting of eight indices. The approach is based on the analysis of the erythrocyte vesiculation. The erythrocyte morphology is analyzed by scanning flow cytometry that measures the primary characteristics (diameter, thickness, and waist) of individual cells. The surface area (S) and sphericity index (SI) are calculated from the primary characteristics and the scattering diagram SI versus S is used in the evaluation of the derived age of each erythrocyte in a sample. We developed the algorithm to evaluate the derived age that provides eight indices in the aging category based on a model using light scatter features. The novel erythrocyte indices were measured for simulated cells and blood samples of 50 donors. We determined the first-ever reference intervals for these indices.


Assuntos
Índices de Eritrócitos , Eritrócitos , Humanos , Lactente , Citometria de Fluxo/métodos
4.
Cytometry A ; 103(1): 39-53, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35349217

RESUMO

Molecular/cell level of gas exchange function assumes the accurate measurement of erythrocyte characteristics and rate constants concerning to molecules involved into the CO2 /O2 transport. Unfortunately, common hematology analyzers provide the measurement of eight indices of erythrocytes only and say little about erythrocyte morphology and nothing about rate constants of cellular function. The aim of this study is to demonstrate the ability of the Scanning Flow Cytometer (SFC) in the complete morphological analysis of mature erythrocytes and characterization of erythrocyte function via measurement of lysing kinetics. With this study we are introducing 48 erythrocyte indices. To provide the usability of application of the SFC in clinical diagnosis, we formed four categories of indices which are as follows: content/concentration (9 indices), morphology (26 indices), age (5 indices), and function (8 indices). The erythrocytes of 39 healthy volunteers were analyzed with the SFC to fix the first-ever reference intervals for the new indices introduced. The essential measurable reliability of the presented method is expressed in terms of errors of characteristics of single erythrocytes retrieved from the solution of the inverse light-scattering problem and errors of parameters retrieved from the fitting of the experimental kinetics by molecular-kinetics model of erythrocyte lysis.


Assuntos
Índices de Eritrócitos , Eritrócitos , Humanos , Citometria de Fluxo/métodos , Reprodutibilidade dos Testes , Morte Celular
5.
Biomed Opt Express ; 7(4): 1305-10, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-27446656

RESUMO

We propose a method for characterization of mature red blood cells (RBCs) morphology, based on measurement of light-scattering patterns (LSPs) of individual RBCs with the scanning flow cytometer and on solution of the inverse light-scattering (ILS) problem for each LSP. We considered a RBC shape model, corresponding to the minimal bending energy of the membrane with isotropic elasticity, and constructed an analytical approximation, which allows rapid simulation of the shape, given the diameter and minimal and maximal thicknesses. The ILS problem was solved by the nearest-neighbor interpolation using a preliminary calculated database of 250,000 theoretical LSPs. For each RBC in blood sample we determined three abovementioned shape characteristics and refractive index, which also allows us to calculate volume, surface area, sphericity index, spontaneous curvature, hemoglobin concentration and content.

6.
Opt Express ; 18(6): 5681-90, 2010 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-20389584

RESUMO

The discrete sources method (DSM) and the discrete dipole approximation (DDA) were compared for simulation of light scattering by a red blood cell (RBC) model. We considered RBCs with diameters up to 8 mum (size parameter up to 38), relative refractive indices 1.03 and 1.06, and two different orientations. The agreement in the angle-resolved S(11) element of the Mueller matrix obtained by these methods is generally good, but it deteriorates with increasing scattering angle, diameter and refractive index of a RBC. Based on the DDA simulations with very fine discretization (up to 93 dipoles per wavelength) for a single RBC, we attributed most of the disagreement to the DSM, which results contain high-frequency ripples. For a single orientation of a RBC the DDA is comparable to or faster than the DSM. However, the relation is reversed when a set of particle orientations need to be simulated at once. Moreover, the DSM requires about an order of magnitude less computer memory. At present, application of the DSM for massive calculation of light scattering patterns of RBCs is hampered by its limitations in size parameter of a RBC due to the high number of harmonics used for calculations.


Assuntos
Eritrócitos/citologia , Eritrócitos/fisiologia , Iluminação/métodos , Modelos Cardiovasculares , Nefelometria e Turbidimetria/métodos , Simulação por Computador , Luz , Espalhamento de Radiação
7.
J Biomed Opt ; 14(6): 064036, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20059274

RESUMO

We characterize T- and B-lymphocytes from several donors, determining cell diameter, ratio of nucleus to cell diameter, and refractive index of the nucleus and cytoplasm for each individual cell. We measure light-scattering profiles with a scanning flow cytometer and invert the signals using a coated sphere as an optical model of the cell and by relying on a global optimization technique. The main difference in morphology of T- and B-lymphocytes is found to be the larger mean diameters of the latter. However, the difference is smaller than the natural biological variability of a single cell. We propose nuclear inhomogeneity as a possible reason for the deviation of measured light-scattering profiles from real lymphocytes from those obtained from the coated sphere model.


Assuntos
Linfócitos B/citologia , Luz , Modelos Biológicos , Espalhamento de Radiação , Linfócitos T/citologia , Algoritmos , Teorema de Bayes , Núcleo Celular , Forma Celular , Tamanho Celular , Citometria de Fluxo , Humanos , Microscopia Confocal , Refratometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...