Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 122(23): 235001, 2019 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-31298873

RESUMO

The first systematic study of opacity dependence on atomic number at stellar interior temperatures is used to evaluate discrepancies between measured and modeled iron opacity [J. E. Bailey et al., Nature (London) 517, 56 (2015)NATUAS0028-083610.1038/nature14048]. High-temperature (>180 eV) chromium and nickel opacities are measured with ±6%-10% uncertainty, using the same methods employed in the previous iron experiments. The 10%-20% experiment reproducibility demonstrates experiment reliability. The overall model-data disagreements are smaller than for iron. However, the systematic study reveals shortcomings in models for density effects, excited states, and open L-shell configurations. The 30%-45% underestimate in the modeled quasicontinuum opacity at short wavelengths was observed only from iron and only at temperature above 180 eV. Thus, either opacity theories are missing physics that has nonmonotonic dependence on the number of bound electrons or there is an experimental flaw unique to the iron measurement at temperatures above 180 eV.

2.
Artigo em Inglês | MEDLINE | ID: mdl-32165874

RESUMO

We review the 9th NLTE code comparison workshop, which was held in the Jussieu campus, Paris, from November 30th to December 4th, 2015. This time, the workshop was mainly focused on a systematic investigation of iron NLTE steady-state kinetics and emissivity, over a broad range of temperature and density. Through these comparisons, topics such as modeling of the dielectronic processes, density effects or the effect of an external radiation field were addressed. The K-shell spectroscopy of iron plasmas was also addressed, notably through the interpretation of tokamak and laser experimental spectra.

4.
Nature ; 517(7532): 56-9, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25557711

RESUMO

Nearly a century ago it was recognized that radiation absorption by stellar matter controls the internal temperature profiles within stars. Laboratory opacity measurements, however, have never been performed at stellar interior conditions, introducing uncertainties in stellar models. A particular problem arose when refined photosphere spectral analysis led to reductions of 30-50 per cent in the inferred amounts of carbon, nitrogen and oxygen in the Sun. Standard solar models using the revised element abundances disagree with helioseismic observations that determine the internal solar structure using acoustic oscillations. This could be resolved if the true mean opacity for the solar interior matter were roughly 15 per cent higher than predicted, because increased opacity compensates for the decreased element abundances. Iron accounts for a quarter of the total opacity at the solar radiation/convection zone boundary. Here we report measurements of wavelength-resolved iron opacity at electron temperatures of 1.9-2.3 million kelvin and electron densities of (0.7-4.0) × 10(22) per cubic centimetre, conditions very similar to those in the solar region that affects the discrepancy the most: the radiation/convection zone boundary. The measured wavelength-dependent opacity is 30-400 per cent higher than predicted. This represents roughly half the change in the mean opacity needed to resolve the solar discrepancy, even though iron is only one of many elements that contribute to opacity.

5.
Rev Sci Instrum ; 83(10): 10E134, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126955

RESUMO

An x-ray grating spectrometer was built in order to measure opacities in the 50 eV to 250 eV spectral range with an average spectral resolution ∼ 50. It has been used at the LULI-2000 laser facility at École Polytechnique (France) to measure the Δn = 0, n = 3 transitions of several elements with neighboring atomic number: Cr, Fe, Ni, and Cu in the same experimental conditions. Hence a spectrometer with a wide spectral range is required. This spectrometer features one line of sight looking through a heated sample at backlighter emission. It is outfitted with one toroidal condensing mirror and several flat mirrors cutting off higher energy photons. The spectral dispersion is obtained with a flatfield grating. Detection consists of a streak camera sensitive to soft x-ray radiation. Some experimental results showing the performance of this spectrometer are presented.

6.
Phys Rev E Stat Nonlin Soft Matter Phys ; 84(3 Pt 2): 036407, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22060513

RESUMO

This paper deals with theoretical studies on the 2p-3d absorption in iron, nickel, and copper plasmas related to LULI2000 (Laboratoire pour l'Utilisation des Lasers Intenses, 2000J facility) measurements in which target temperatures were of the order of 20 eV and plasma densities were in the range 0.004-0.01 g/cm(3). The radiatively heated targets were close to local thermodynamic equilibrium (LTE). The structure of 2p-3d transitions has been studied with the help of the statistical superconfiguration opacity code SCO and with the fine-structure atomic physics codes HULLAC and FAC. A new mixed version of the sco code allowing one to treat part of the configurations by detailed calculation based on the Cowan's code RCG has been also used in these comparisons. Special attention was paid to comparisons between theory and experiment concerning the term features which cannot be reproduced by SCO. The differences in the spin-orbit splitting and the statistical (thermal) broadening of the 2p-3d transitions have been investigated as a function of the atomic number Z. It appears that at the conditions of the experiment the role of the term and configuration broadening was different in the three analyzed elements, this broadening being sensitive to the atomic number. Some effects of the temperature gradients and possible non-LTE effects have been studied with the help of the radiative-collisional code SCRIC. The sensitivity of the 2p-3d structures with respect to temperature and density in medium-Z plasmas may be helpful for diagnostics of LTE plasmas especially in future experiments on the Δn=0 absorption in medium-Z plasmas for astrophysical applications.

7.
Rev Sci Instrum ; 79(11): 113104, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19045886

RESUMO

Understanding stellar interiors, inertial confinement fusion, and Z pinches depends on opacity models for mid-Z plasmas in the 100-300 eV temperature range. These models are complex and experimental validation is crucial. In this paper we describe the diagnosis of the first experiments to measure iron plasma opacity at a temperature high enough to produce the charge states and electron configurations that exist in the solar interior. The dynamic Hohlraum x-ray source at Sandia National Laboratories' Z facility was used to both heat and backlight Mg/Fe CH tamped foils. The backlighter equivalent brightness temperature was estimated to be T(r) approximately 314 eV+/-8% using time-resolved x-ray power and imaging diagnostics. This high brightness is significant because it overwhelms the sample self-emission. The sample transmission in the 7-15.5 A range was measured using two convex potassium acid phthalate crystal spectrometers that view the backlighter through the sample. The average spectral resolution over this range was estimated to be lambda/deltalambda approximately 700 by comparing theoretical crystal resolution calculations with measurements at 7.126, 8.340, and 12.254 A. The electron density was determined to be n(e)=6.9+/-1.7 x 10(21) cm(-3) using the Stark-broadened Mg Hebeta, Hegamma, and Hedelta lines. The temperature inferred from the H-like to He-like Mg line ratios was T(e)=156+/-6 eV. Comparisons with three different spectral synthesis models all have normalized chi(2) that is close to unity, indicating quantitative consistency in the inferred plasma conditions. This supports the reliability of the results and implies the experiments are suitable for testing iron opacity models.

8.
Phys Rev E Stat Nonlin Soft Matter Phys ; 65(1 Pt 2): 016413, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11800796

RESUMO

Absorption of L-M and L-N transitions of nickel has been measured using point projection spectroscopy. The x-ray radiation from laser-irradiated gold cavities was used to heat volumetrically nickel foils "tamped with carbon" up to 20 eV. Experimental spectra have been analyzed with calculations based on the spin-orbit split arrays statistical approach and performed for each ionic species Ni5+ to Ni11+. Using a least-squares fit, this method provides an ion distribution broader than at local thermodynamic equilibrium, which is explained by spatial and temporal temperature gradients. A major improvement in the simulation of the absolute value of transmission is obtained with a resolved transition array statistical calculation that reproduces the experimental spectrum with the nominal areal mass density by taking into account the saturation of narrow lines.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...