Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Heart Assoc ; 11(22): e026041, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36346050

RESUMO

Background In a previous trial, higher 5-year mortality was observed following treatment with biodegradable polymer Orsiro sirolimus-eluting stents (SES). We assessed 5-year safety and efficacy of all-comers as well as patients with diabetes treated with SES or Synergy everolimus-eluting stents (EES) versus durable polymer Resolute Integrity zotarolimus-eluting stents (ZES). Methods and Results The randomized BIO-RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population) trial enrolled 3514 all-comer patients at 4 Dutch cardiac centers. Patients aged ≥18 years who required percutaneous coronary intervention were eligible. Participants were stratified for diabetes and randomized to treatment with SES, EES, or ZES (1:1:1). The main end point was target vessel failure (cardiac mortality, target vessel myocardial infarction, or target vessel revascularization). Five-year follow-up was available in 3183 of 3514 (90.6%) patients. The main end point target vessel failure occurred in 142 of 1169 (12.7%) patients treated with SES, 130 of 1172 (11.6%) treated with EES, versus 157 of 1173 (14.1%) treated with ZES (hazard ratio [HR], 0.89 [95% CI, 0.71-1.12], Plog-rank=0.31; and HR, 0.82 [95% CI, 0.65-1.04], Plog-rank=0.10, respectively). Individual components of target vessel failure showed no significant between-stent difference. Very late definite stent thrombosis rates were low and similar (SES, 1.1%; EES, 0.6%; ZES, 0.9%). In patients with diabetes, target vessel failure did not differ significantly between stent-groups (SES, 19.8%; EES, 19.2%; versus ZES, 21.1% [Plog-rank=0.69 and Plog-rank=0.63]). Conclusions Orsiro SES, Synergy EES, and Resolute Integrity ZES showed similar 5-year outcomes of safety and efficacy, including mortality. A prespecified stent comparison in patients with diabetes also revealed no significant differences in 5-year clinical outcomes. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01674803.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Adolescente , Adulto , Desenho de Prótese , Resultado do Tratamento , Everolimo , Intervenção Coronária Percutânea/efeitos adversos , Polímeros , Diabetes Mellitus/etiologia , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia
2.
Lancet ; 388(10060): 2607-2617, 2016 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-27806902

RESUMO

BACKGROUND: In patients with coronary artery disease, treated with durable polymer-coated drug-eluting stents, the life-long presence of the polymer might delay arterial healing. Novel very thin strut biodegradable polymer stents, which leave only a bare metal stent after polymer resorption, might improve long-term outcome. We investigated in allcomers the safety and efficacy of three stents eluting either everolimus, sirolimus, or zotarolimus, often clinically used but never compared, of which the biodegradable polymer everolimus-eluting stent was never before assessed in allcomers. METHODS: The large-scale, investigator-initiated, multicentre, assessor and patient blinded, three-arm, randomised, BIO-RESORT non-inferiority trial was done at four clinical sites in the Netherlands. All-comer patients were aged 18 years or older, capable of providing informed consent, and required a percutaneous coronary intervention with drug-eluting stent implantation according to clinical guidelines or the operators' judgment. Exclusion criteria were: participation in another randomised drug or device study before reaching the primary endpoint of that study; planned surgery necessitating interruption of dual antiplatelet therapy within the first 6 months; known intolerance to components of the investigational product or medication required; uncertainty about the adherence to follow-up procedures or an assumed life expectancy of less than 1 year; or known pregnancy. Web-based computer-generated allocation sequences randomly assigned patients (1:1:1) to treatment with very thin strut biodegradable polymer everolimus-eluting or sirolimus-eluting stents (which differ substantially in type, amount, distribution, and resorption speed of their respective coating), or thin strut durable polymer zotarolimus-eluting stents. The primary endpoint was a composite of safety (cardiac death or target vessel-related myocardial infarction) and efficacy (target vessel revascularisation) at 12 months of follow up with a very thin strut biodegradable polymer of either everolimus-eluting or sirolimus-eluting stents, compared with durable polymer zotarolimus-eluting stents, analysed by intention to treat (non-inferiority margin 3·5%). This trial was registered with ClinicalTrials.gov, number NCT01674803. FINDINGS: From Dec 21, 2012, to Aug 24, 2015, 3514 patients were enrolled and analysed, of whom 2449 (70%) had acute coronary syndromes, which included 1073 (31%) ST-elevation myocardial infarctions. 12 month follow-up of 3490 (99%) patients (three lost to follow-up; 21 withdrawals) was available. The primary endpoint was met by 55 (5%) of 1172 patients assigned to everolimus-eluting stents, 55 (5%) of 1169 assigned to sirolimus-eluting stents and 63 (5%) of 1173 assigned to zotarolimus-eluting stents. Non-inferiority of the everolimus-eluting stents and sirolimus-eluting stents compared with zotarolimus-eluting stents was confirmed (both -0·7% absolute risk difference, 95% CI -2·4 to 1·1; upper limit of one sided 95% CI 0·8%, pnon-inferiority<0·0001). Definite stent thrombosis (defined by the Academic Research Consortium) occurred in four (0·3%) of 1172 patients who were allocated to everolimus-eluting stents, four (0·3%) of 1169 patients who were allocated to sirolimus-eluting stents, and three (0·3%) of 1173 patients who were allocated to zotarolimus-eluting stents (log-rank p=0·70 for both comparisons with zotarolimus-eluting stents). INTERPRETATION: At 12 month follow-up, both very thin strut drug-eluting stents with dissimilar biodegradable polymer coatings (eluting either everolimus or sirolimus) were non-inferior to the durable polymer stent (eluting zotarolimus) in treating allcomers with a high proportion of patients with acute coronary syndromes. The absence of a loss of 1 year safety and efficacy with the use of these two biodegradable polymer-coated stents is a prerequisite before assessing their potential longer-term benefits. FUNDING: Biotronik, Boston Scientific, and Medtronic.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Antibacterianos/uso terapêutico , Stents Farmacológicos , Everolimo , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Implantes Absorvíveis , Idoso , Antibacterianos/administração & dosagem , Doença das Coronárias/cirurgia , Feminino , Humanos , Imunossupressores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Polímeros , Sirolimo/administração & dosagem , Sirolimo/análise , Resultado do Tratamento
3.
Lancet ; 383(9915): 413-23, 2014 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24183564

RESUMO

BACKGROUND: Third-generation, permanent-polymer-based drug-eluting stents with novel, flexible designs might be more easily delivered than previous generations of stents in complex coronary lesions, but might be less longitudinally stable. We aimed to assess the safety and efficacy in all-comer patients of two third-generation stents that are often used clinically, but that have not yet been compared, and one of which has not previously been assessed in a randomised trial. METHODS: In this investigator-initiated, single-blind, multicentre, randomised, two-arm, non-inferiority trial, patients aged 18 years and older who required a percutaneous coronary intervention with implantation of a drug-eluting stent were recruited from four study sites in the Netherlands. We randomly assigned patients by independently managed computer-generated allocation sequences in a 1:1 ratio to receive either cobalt-chromium-based zotarolimus-eluting stents (Resolute Integrity, Medtronic, Santa Rosa, CA, USA) or platinum-chromium-based everolimus-eluting stents (Promus Element, Boston Scientific, Natick, MA, USA). Patients and analysts were masked to the allocated stent, but treating clinicians were not. The primary endpoint of target-vessel failure was a composite of safety (cardiac death or target-vessel-related myocardial infarction) and efficacy (target-vessel revascularisation) at 12 months, analysed by intention to treat (with a non-inferiority margin of 3·6%). This trial is registered with ClinicalTrials.gov, number NCT01331707. FINDINGS: Between Nov 25, 2010, and May 24, 2012, 1811 eligible all-comer patients, with 2371 target lesions, were enrolled in the study. 370 (20%) patients presented with ST-elevation myocardial infarction and 447 (25%) with non-ST-elevation myocardial infarction. 906 patients were assigned to receive zotarolimus-eluting stents and 905 to receive everolimus-eluting stents. Ease of stent delivery was shown by very low numbers of patients requiring treatment other than their assigned study treatment (six [1%] in the zotarolimus-eluting stent group vs five [1%] in the everolimus-eluting stent group; p=0·22). 12-month follow-up results were available for 1810 patients (one patient in the zotarolimus-eluting stent group withdrew consent). The primary endpoint was met by 55 (6%) of 905 patients in the zotarolimus-eluting stent group and 47 (5%) of 905 in the everolimus-eluting stent group. The zotarolimus-eluting stent was non-inferior to the everolimus-eluting stent (absolute risk difference 0·88%, 95% CI -1·24% to 3·01%; upper limit of one-sided 95% CI 2·69%; non-inferiority p=0·006). We noted no significant between-group differences in individual components of the primary endpoint. Definite stent thrombosis occurred in three (0·3%) patients in the zotarolimus-eluting stent group and six (0·7%) patients in the everolimus-eluting stent group (p=0·34). Longitudinal stent deformation was seen only in the everolimus-eluting stent group (nine [1·0%] of 905 vs 0 of 906, p=0·002; nine of 1591 [0·6%] everolimus-eluting stents implanted became deformed), but was not associated with any adverse events. INTERPRETATION: Both stents were similarly efficacious and safe, and provided excellent clinical outcomes, especially in view of the large number of patients who presented with acute myocardial infarctions. FUNDING: Boston Scientific, Medtronic.


Assuntos
Imunossupressores/administração & dosagem , Infarto do Miocárdio/tratamento farmacológico , Intervenção Coronária Percutânea/métodos , Sirolimo/análogos & derivados , Adulto , Idoso , Idoso de 80 Anos ou mais , Oclusão Coronária/tratamento farmacológico , Morte Súbita Cardíaca/etiologia , Stents Farmacológicos , Everolimo , Feminino , Humanos , Imunossupressores/efeitos adversos , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...