1.
PLoS One ; 8(11): e78562, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24244323

RESUMO

Mitochondrial electron transport chain (ETC) defects are observed in Parkinson's disease (PD) patients and in PD fly- and mouse-models; however it remains to be tested if acute improvement of ETC function alleviates PD-relevant defects. We tested the hypothesis that 808 nm infrared light that effectively penetrates tissues rescues pink1 mutants. We show that irradiating isolated fly or mouse mitochondria with 808 nm light that is absorbed by ETC-Complex IV acutely improves Complex IV-dependent oxygen consumption and ATP production, a feature that is wavelength-specific. Irradiating Drosophila pink1 mutants using a single dose of 808 nm light results in a rescue of major systemic and mitochondrial defects. Time-course experiments indicate mitochondrial membrane potential defects are rescued prior to mitochondrial morphological defects, also in dopaminergic neurons, suggesting mitochondrial functional defects precede mitochondrial swelling. Thus, our data indicate that improvement of mitochondrial function using infrared light stimulation is a viable strategy to alleviate pink1-related defects.


Assuntos
Trifosfato de Adenosina/metabolismo , Proteínas de Drosophila/metabolismo , Complexo IV da Cadeia de Transporte de Elétrons/metabolismo , Consumo de Oxigênio , Doença de Parkinson/metabolismo , Proteínas Serina-Treonina Quinases/metabolismo , Trifosfato de Adenosina/genética , Animais , Modelos Animais de Doenças , Proteínas de Drosophila/genética , Drosophila melanogaster , Complexo IV da Cadeia de Transporte de Elétrons/genética , Humanos , Luz , Camundongos , Doença de Parkinson/genética , Proteínas Serina-Treonina Quinases/genética
2.
Neuromodulation ; 14(3): 235-41; discussion 241, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21992246

RESUMO

OBJECTIVE: Flow-rate accuracy and precision are important parameters to optimizing the efficacy of programmable intrathecal (IT) infusion pump delivery systems. Current programmable IT pumps are accurate within ±14.5% of their programmed infusion rate when assessed under ideal environmental conditions and specific flow-rate settings in vitro. We assessed the flow-rate accuracy of a novel programmable pump system across its entire flow-rate range under typical conditions in sheep (in vivo) and nominal conditions in vitro. MATERIALS AND METHODS: The flow-rate accuracy of the MedStream Programmable Pump was assessed in both the in vivo and in vitro settings. In vivo flow-rate accuracy was assessed in 16 sheep at various flow-rates (producing 90 flow intervals) more than 90 ± 3 days. Pumps were then explanted, re-sterilized and in vitro flow-rate accuracy was assessed at 37°C and 1013 mBar (80 flow intervals). RESULTS: In vivo (sheep body temperatures 38.1°C-39.8°C), mean ± SD flow-rate error was 9.32% ± 9.27% and mean ± SD leak-rate was 0.028 ± 0.08 mL/day. Following explantation, mean in vitro flow-rate error and leak-rate were -1.05% ± 2.55% and 0.003 ± 0.004 mL/day (37°C, 1013 mBar), respectively. CONCLUSIONS: The MedStream Programmable Pump demonstrated high flow-rate accuracy when tested in vivo and in vitro at normal body temperature and environmental pressure as well as when tested in vivo at variable sheep body temperature. The flow-rate accuracy of the MedStream Programmable Pump across its flow-rate range, compares favorably to the accuracy of current clinically utilized programmable IT infusion pumps reported at specific flow-rate settings and conditions.


Assuntos
Bombas de Infusão Implantáveis/normas , Infusão Espinal , Analgésicos/administração & dosagem , Analgésicos/uso terapêutico , Animais , Temperatura Corporal , Dor Crônica/tratamento farmacológico , Humanos , Relaxantes Musculares Centrais/administração & dosagem , Relaxantes Musculares Centrais/uso terapêutico , Espasticidade Muscular/tratamento farmacológico , Reprodutibilidade dos Testes , Ovinos
3.
IEEE Trans Biomed Eng ; 55(4): 1374-81, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18390328

RESUMO

A new implantable pressure sensor for long-term monitoring of intracranial pressure is presented. The sensor is powered by telemetry and can be interrogated wirelessly. A capacitive pressure transducer, whose capacitance is converted to a frequency-encoded signal by an application-specific integrated circuit (ASIC), senses the absolute pressure. The pressure-encoded signal, the ASIC input voltage, and onboard calibration parameters are transmitted to an external reading unit. The proposed novel packaging solution is designed for long-term stability and reliability of the sensor. The accuracy of sensor at body temperature is better than 2 mbar across a pressure range of 600-1200 mbar. The sensor is 13 mm in diameter and 4.5 mm in height.


Assuntos
Engenharia Biomédica/instrumentação , Pressão Intracraniana/fisiologia , Manometria/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Telemetria/instrumentação , Engenharia Biomédica/métodos , Diagnóstico por Computador/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Sensibilidade e Especificidade , Telemetria/métodos , Transdutores
4.
IEEE Trans Biomed Eng ; 54(4): 726-33, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17405380

RESUMO

The goal of this study was to propose a general numerical analysis methodology to evaluate the magnetic resonance imaging (MRI)-safety of active implants. Numerical models based on the finite element (FE) technique were used to estimate if the normal operation of an active device was altered during MRI imaging. An active implanted pump was chosen to illustrate the method. A set of controlled experiments were proposed and performed to validate the numerical model. The calculated induced voltages in the important electronic components of the device showed dependence with the MRI field strength. For the MRI radiofrequency fields, significant induced voltages of up to 20 V were calculated for a 0.3T field-strength MRI. For the 1.5 and 3.0OT MRIs, the calculated voltages were insignificant. On the other hand, induced voltages up to 11 V were calculated in the critical electronic components for the 3.0T MRI due to the gradient fields. Values obtained in this work reflect to the worst case situation which is virtually impossible to achieve in normal scanning situations. Since the calculated voltages may be removed by appropriate protection circuits, no critical problems affecting the normal operation of the pump were identified. This study showed that the proposed methodology helps the identification of the possible incompatibilities between active implants and MR imaging, and can be used to aid the design of critical electronic systems to ensure MRI-safety.


Assuntos
Queimaduras/fisiopatologia , Análise de Falha de Equipamento/métodos , Falha de Equipamento , Reação a Corpo Estranho/fisiopatologia , Bombas de Infusão Implantáveis/efeitos adversos , Imageamento por Ressonância Magnética/efeitos adversos , Modelos Biológicos , Queimaduras/etiologia , Simulação por Computador , Segurança de Equipamentos , Análise de Elementos Finitos , Reação a Corpo Estranho/etiologia , Humanos , Próteses e Implantes/efeitos adversos , Medição de Risco/métodos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS