Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Interv Card Electrophysiol ; 65(2): 453-460, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35513562

RESUMO

PURPOSE: Compliance with anticoagulation treatment for atrial fibrillation is highly variable. Smartphone electrocardiograms that allow patients to have greater insight into their arrhythmia burden may improve anticoagulant compliance. METHODS: Patients were enrolled if they had atrial fibrillation with a CHA2DS2-VASc score of 2 or more, were eligible for anticoagulation and had a smartphone. Participants were randomly assigned to receive a smartphone electrocardiogram (AliveCor Kardia) to record their electrocardiograms 5 times/week or to the control group. All patients received 6 months of anticoagulant (apixaban) dispensed as 1-month pre-loaded pill boxes. RESULTS: A total of 100 patients were enrolled from July 2017 to August 2019, but 5 patients in the monitor arm and 1 in the control arm withdrew prematurely. The monitor and control groups did not differ in age, gender, CHA2DS2-VASc score, or comorbidities. Median medication compliance was 99.7%, with nonsignificantly greater compliance in the monitor group (100%) than in the control group (99.7%) (p-value = 0.247). There was also no significant difference between missing any dose and use/nonuse of the smartphone monitor (48.9% vs. 55.1%; p-value = 0.692). Mean monitor compliance was 86.8% ± 14.0% with an average of 4.34 recorded electrocardiograms per week. Monitor group patients with perfect medication compliance had significantly higher monitor compliance than those patients who missed doses (median 95.3% vs 86.7%; p-value = 0.02). CONCLUSIONS: In a study population with higher-than-expected medication compliance, the use of smartphone electrocardiogram did not demonstrate an improvement in medication compliance as compared to usual care. Greater monitor compliance was associated with greater medication compliance. CLINICAL TRIAL REGISTRATION: BOAT-OAR ClinicalTrials.gov number, NCT03515083.


Assuntos
Anticoagulantes , Fibrilação Atrial , Humanos , Anticoagulantes/uso terapêutico , Smartphone , Eletrocardiografia , Adesão à Medicação
2.
J Interv Card Electrophysiol ; 64(2): 301-310, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33796968

RESUMO

PURPOSE: This registry compared the safety and efficacy of vascular closure device Perclose (PC) with figure-of-eight stitch (Fo8) and manual compression (MC) following catheter ablation of atrial fibrillation/flutter. METHODS: VAscular Closure for Cardiac Ablation Registry (VACCAR) is a prospective, observational registry that assessed the time to hemostasis (TTH), time to ambulation (TTA), length of stay (LOS), complications, patient-reported outcomes, and pain medication use. RESULTS: A total of 434 patients (mean age 64.0±11.0 years; 38% female; 94.9% white) were enrolled between October 2017 and May 2019: 156 in MC, 203 in Fo8, and 75 in the PC group. Median TTH was significantly reduced in the PC and Fo8 group at 7 and 9 min respectively vs. the MC group at 20 min (p<0.001). Median TTA was significantly reduced in both the PC and Fo8 group at 2.2 h vs. the MC group at 6.5 h (p<0.001 for both). Median LOS for the PC group was significantly reduced at 27.5 h compared to the MC and Fo8 group at 29 h (p<0.01). A higher proportion of same-day discharges were noted in the PC and Fo8 groups at 14 (18.7%) and 25 (12.3%), respectively, compared to 5 (3.2%) in the MC group (p<0.01 for all). There was no significant difference in complications between the three groups. CONCLUSIONS: Both PC and Fo8 are safe with improved TTH, TTA, LOS, and a higher number of same-day discharges compared to MC.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/cirurgia , Feminino , Técnicas Hemostáticas , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
3.
Indian Pacing Electrophysiol J ; 20(3): 105-111, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32145397

RESUMO

OBJECTIVES: Comparison of outcomes, device deployment time (DT), and total time (TT) using a single tapered Coons dilator versus sequential serial dilation for implantation of the Micra leadless pacemaker. BACKGROUND: Micra leadless pacemaker placement requires a 23 French Micra introducer sheath (MIS) for percutaneous delivery. We sought to evaluate outcomes with use of a single tapered Coons dilator (CD) versus sequential serial dilatation (SD) method to facilitate insertion of the Micra introducer sheath. METHODS: 35 patients were included in the SD arm and 49 in the CD arm. DT and TT were recorded in minutes and cost in dollars. Analysis was performed using independent t-test between two groups and one-way ANOVA to evaluate inter-operator variability in the CD arm. RESULTS: Both DT and TT were significantly lower for the CD arm (15.1 ± 5.1 vs 23.5 ± 9.3, p < 0.0005 and 29.9 ± 14 vs 39.3 ± 13.5 min, p = 0.000374; respectively). The cost was also significantly lower using a CD versus SD. There was no inter-operator variability in the CD arm between 6 operators (p = 0.177 for DT and p = 0.304 for TT). No complications occurred in the SD arm. There were 3 vascular access site complications in the CD arm, all of which occurred early in the operator's experience. CONCLUSION: Coons dilator is an efficient and cost-effective method for vascular dilatation to facilitate Micra leadless pacemaker insertion. Rate of complications is low and expected to improve with greater experience.

4.
J Clin Invest ; 116(7): 2012-21, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16823493

RESUMO

Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVC) is a genetic disease caused by mutations in desmosomal proteins. The phenotypic hallmark of ARVC is fibroadipocytic replacement of cardiac myocytes, which is a unique phenotype with a yet-to-be-defined molecular mechanism. We established atrial myocyte cell lines expressing siRNA against desmoplakin (DP), responsible for human ARVC. We show suppression of DP expression leads to nuclear localization of the desmosomal protein plakoglobin and a 2-fold reduction in canonical Wnt/beta-catenin signaling through Tcf/Lef1 transcription factors. The ensuing phenotype is increased expression of adipogenic and fibrogenic genes and accumulation of fat droplets. We further show that cardiac-restricted deletion of Dsp, encoding DP, impairs cardiac morphogenesis and leads to high embryonic lethality in the homozygous state. Heterozygous DP-deficient mice exhibited excess adipocytes and fibrosis in the myocardium, increased myocyte apoptosis, cardiac dysfunction, and ventricular arrhythmias, thus recapitulating the phenotype of human ARVC. We believe our results provide for a novel molecular mechanism for the pathogenesis of ARVC and establish cardiac-restricted DP-deficient mice as a model for human ARVC. These findings could provide for the opportunity to identify new diagnostic markers and therapeutic targets in patients with ARVC.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desmoplaquinas/metabolismo , Transdução de Sinais/fisiologia , Proteínas Wnt/metabolismo , beta Catenina/metabolismo , gama Catenina/metabolismo , Adipogenia/fisiologia , Animais , Displasia Arritmogênica Ventricular Direita/metabolismo , Displasia Arritmogênica Ventricular Direita/patologia , Núcleo Celular/metabolismo , Células Cultivadas , Desmoplaquinas/genética , Eletrofisiologia , Embrião de Mamíferos/anatomia & histologia , Embrião de Mamíferos/fisiologia , Átrios do Coração/citologia , Átrios do Coração/patologia , Humanos , Camundongos , Camundongos Knockout , Miócitos Cardíacos/citologia , Miócitos Cardíacos/fisiologia , Fenótipo , RNA Interferente Pequeno/genética , RNA Interferente Pequeno/metabolismo , Fatores de Transcrição TCF/metabolismo , Proteínas Wnt/genética , beta Catenina/genética , gama Catenina/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...