Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 154
Filtrar
1.
Clin Res Cardiol ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39046472

RESUMO

BACKGROUND: To assess the interaction between heart failure (HF) severity and optimal reduction of secondary mitral regurgitation (SMR) on mortality in patients undergoing transcatheter edge-to-edge repair (M-TEER). METHODS AND RESULTS: Among 1656 patients included in the Italian Society of Interventional Cardiology (GIse) registry Of Transcatheter treatment of mitral valve regurgitaTiOn (GIOTTO) 984 had SMR and complete data on advanced HF. Advanced HF was defined as NYHA class III or IV, left ventricular ejection fraction ≤ 30%, and > 1 HF hospitalization during the last 12 months. Optimal M-TEER was defined as residual SMR ≤ 1 + at discharge. One hundred sixteen patients (11.8%) had advanced HF. Achievement of an optimal SMR reduction was similar in patients with and without advanced HF (65% and 60% respectively). Advanced HF was an independent predictor of 2-year all-cause death (adjusted HR 1.52, 95% CI 1.09-2.10). Optimal M-TEER, as compared to a no-optimal M-TEER, was associated with a reduced risk of death both in patients with advanced (HR 0.55, 95% CI 0.32-0.97; p = 0.039) and no-advanced HF (HR 0.59, 95% CI 0.46-0.78; p < 0.001; p = 0.778 for interaction). CONCLUSIONS: Advanced HF is associated with poor outcome in patients undergoing M-TEER. However, an optimal SMR reduction reduces the risk of 2-year mortality regardless of HF severity.

2.
Int J Cardiol ; 413: 132317, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986745

RESUMO

AIM: The aims of this study were: i) to report the prevalence of low-risk patients with degenerative mitral regurgitation (DMR) undergoing mitral transcatheter edge-to-edge repair (M-TEER) in a real-world setting; ii) to evaluate the prognostic significance of EuroSCORE II; iii) to determine whether an optimal M-TEER provides a mortality benefit regardless of EuroSCORE-II. METHODS: We analyzed data from the GIOTTO registry that enrolled patients undergoing M-TEER in Italy. We included only patients with DMR. Two groups were defined: patients with EuroSCORE<4% and with EuroSCORE≥4%. A further stratification according to variables included in the EuroSCORE-II was made. Interaction between EuroSCORE-II and optimal procedural success was evaluated. Outcome of interest was all-cause death at 2-year. RESULTS: Among 1659 patients prospectively enrolled in the GIOTTO registry, 657 had DMR, 364 with an EuroSCORE<4% (53%) and 311 with an EuroSCORE≥4% (47%). Patients with lower EuroSCORE were older with less comorbidities. All-cause mortality was higher in patients with EuroSCORE≥ vs <4%. EuroSCORE II ≥ 4% was independently associated with an increased risk of mortality (HR 2.36, 95%CI 1.28-4.38, p = 0.007). Among variables included in the EuroSCORE-II, Left Ventricular Ejection Fraction<35% and systolic Pulmonary Artery Pressure ≥ 50mmhg were independent predictors of clinical outcome. Two-year all-cause death was higher in patients without optimal MR reduction regardless of the calculated surgical risk (p for interaction 0.3). CONCLUSION: More than half of patients with DMR undergoing M-TEER had a Euroscore<4% with a median age of 81. An optimally successful M-TEER was associated with a lower mortality regardless of EuroSCORE.

3.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986659

RESUMO

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Feminino , Masculino , Estudos Retrospectivos , Idoso , Resultado do Tratamento , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Readmissão do Paciente , Recuperação de Função Fisiológica , Europa (Continente) , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Hemodinâmica
4.
Minerva Med ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38867594

RESUMO

Cardiovascular disease remains decade after decade a leading cause of mortality, morbidity and resource use globally as well as locally. We have had the opportunity of being involved in several iterative breakthroughs in invasive cardiovascular procedures, ranging from the advent of coronary stents to transcatheter mitral valve repair. Building up such extensive clinical and research experience, we hereby present 25 years of cardiovascular interventions at Pineta Grande Hospital and Casa di Salute S. Lucia, respectively in Castel Volturno, and S. Giuseppe Vesuviano, both in the Italian Campania region, where the same team of interventional cardiologists has managed to adopt and master several cardiovascular innovations for the benefit of thousands of patients. Our experience showcases the evolution of invasive cardiology, especially in diagnostic and therapeutic practices. Key highlights include advancements in coronary procedures, with the introduction of bare-metal stents, drug-eluting stents and drug-coated balloons, despite the setback of bioresorbable vascular scaffolds, as well as transcatheter aortic valve implantation and innovative approaches to mitral regurgitation. Furthermore, this overview scrutinizes procedural challenges, patient outcomes, and quality of life improvements, providing a rich tapestry of clinical experiences and research insights. It serves as a testament to the dynamic nature of interventional cardiology, offering a forward-looking perspective on future trends and technologies. We hope that this overview will prove an informative and insightful read for those seeking to understand the intricate journey of invasive cardiovascular care over the past decades and its trajectory into the future.

5.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38742523

RESUMO

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Sistema de Registros , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Masculino , Feminino , Idoso , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Itália/epidemiologia , Idoso de 80 Anos ou mais , Readmissão do Paciente/estatística & dados numéricos , Falha de Tratamento , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/instrumentação , Anuloplastia da Valva Mitral/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia
7.
J Invasive Cardiol ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38598251

RESUMO

OBJECTIVES: Transcatheter edge-to-edge repair (TEER) has become an established minimally invasive treatment for significant mitral regurgitation. Ongoing refinements and the availability of different clipping devices have expanded the indications for and effectiveness of TEER, but comprehensive comparative data on this issue are lacking. In this study, we compared NT, NTr, and XTr MitraClip devices (Abbot) for TEER. METHODS: Details on patient, imaging, and procedural details, as well as short- and long-term outcomes, were sought from a national prospective clinical registry on TEER with MitraClip. The primary outcome of interest was discharge after procedural success without major clinical complications. RESULTS: A total of 2236 patients were included, 1228 (54.9%) in whom NT implantation only was attempted, 233 (10.4%) in whom NTr but not XTr implantation was attempted, and 775 (34.7%) in whom XTr implantation was attempted. Clinical and imaging features differed substantially across the groups, reflecting expanding indications with NTr and XTr devices. In-hospital outcomes were largely similar among the 3 groups, including death. Long-term unadjusted estimates of effect showed significant differences in several outcomes, including death, rehospitalization, and their composite, which demonstrated that NT was associated with more unfavorable outcomes compared with the other devices (all P less than .05). However, most differences depended on baseline features, as adjusted analysis showed no significant differences for early as well as long-term outcomes, including long-term death, rehospitalization, and their composite (all P greater than .05). CONCLUSIONS: New-generation MitraClip devices are associated with favorable procedural and clinical outcomes, despite being used in patients with more adverse features, when compared with patients treated with previous devices.

9.
Clin Res Cardiol ; 113(1): 86-93, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37391628

RESUMO

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic valve stenosis in elderly patients, but there is uncertainty on their long-term effectiveness. We aimed to assess the long-term outcome of patients undergoing TAVI with the Portico valve. METHODS: We retrospectively collected the data on patients in whom TAVI with Portico was attempted from 7 high-volume centres. Only patients theoretically eligible for 3 or more years of follow-up were included. Clinical outcomes, including death, stroke, myocardial infarction, reintervention for valve degeneration and hemodynamic valve performance were systematically assessed. RESULTS: A total of 803 patients were included, with 504 (62.8%) women, mean age of 82 years, median EuroSCORE II of 3.1%, and 386 (48.1%) subjects at low/moderate risk. The median follow-up was 3.0 years (3.0; 4.0). The composite of death, stroke, myocardial infarction, and reintervention for valve degeneration occurred in 37.5% (95% confidence interval: 34.1-40.9%), with all-cause death in 35.1% (31.8-38.4%), stroke in 3.4% (1.3-3.4%), myocardial infarction in 1.0% (0.3-1.5%), and reintervention for valve degeneration in 1.1% (0.6-2.1%). The mean aortic valve gradient at follow-up was 8.1 ± 4.6 mmHg, and at least moderate aortic regurgitation was present in 9.1% (6.7-12.3%). Independent predictors of major adverse events or death were: peripheral artery disease, chronic obstructive pulmonary disease, estimated glomerular filtration rate, atrial fibrillation, prior pacemaker implantation, EuroSCORE II, and reduced left ventricular ejection fraction (all p < 0.05). CONCLUSIONS: Portico use is associated with favorable long-term clinical outcomes. Clinical outcomes were largely impacted by baseline risk factors and surgical risk.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Infarto do Miocárdio , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Estenose da Valva Aórtica/cirurgia , Acidente Vascular Cerebral/etiologia
10.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37138103

RESUMO

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Sistema de Registros , Desenho de Prótese
11.
Am J Cardiol ; 211: 219-227, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37944779

RESUMO

Atrial functional mitral regurgitation (aFMR) has a peculiar pathophysiology that may have distinctive outcomes. We investigated the impact of transcatheter edge-to-edge repair in aFMR compared with other FMR etiologies. The GIOTTO (GIse registry Of Transcatheter treatment of MR) is a multicenter, prospective study enrolling patients with symptomatic MR treated with MitraClip up to 2020. We categorized patients with FMR as aFMR, ischemic FMR (iFMR), and nonischemic ventricular FMR (niFMR). The clinical end points were defined according to the Mitral Valve Academic Research Consortium. Of 1,153 patients, 6% had aFMR, 47% iFMR, and 47% niFMR. Patients with aFMR were older, mostly women, and had a higher atrial fibrillation rate. They had better left ventricular ejection fraction and smaller left ventricular volumes, with no difference in mitral effective regurgitant orifice area. The acute device and procedural success rates were similar among the groups. At the longest available follow-up (median 478 days, interquartile range 91 to 741 days), the rate of MR ≥2+ was similar among the groups. Patients with aFMR had a lower rate of cardiovascular death and heart failure than patients with iFMR (hazard ratio [HR] 0.43, p = 0.02) and niFMR (HR 0.45, p = 0.03). The aFMR etiology remained independently associated with the composite outcome, together with postprocedural MR ≤1+ (HR 0.63, p <0.01) and peripheral arteriopathy (HR 1.82, p = 0.003). The results of this GIOTTO subanalysis suggested that aFMR is less prevalent and associated with better outcomes compared with other causes of FMR treated by transcatheter edge-to-edge repair. Postprocedural MR >1+, peripheral vasculopathy, non-aFMR were independent predictors of worse outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Feminino , Masculino , Valva Mitral/cirurgia , Volume Sistólico , Estudos Prospectivos , Função Ventricular Esquerda , Sistema de Registros , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos
12.
Clin Res Cardiol ; 113(1): 68-74, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37294310

RESUMO

AIM: Transcatheter aortic valve implantation (TAVI) is a mainstay in the management of severe aortic stenosis in patients with intermediate to prohibitive surgical risk. When a single TAVI device fails and cannot be retrieved, TAVI-in-TAVI must be performed acutely, but outcomes of bailout TAVI-in-TAVI have been incompletely appraised. We aimed at analyzing patient, procedural and outcome features of patients undergoing bailout TAVI-in-TAVI in a multicenter registry. METHODS: Details of patients undergoing bailout TAVI-in-TAVI, performed acutely or within 24 h of index TAVI, in 6 international high-volume institutions, were collected. For every case provided, 2 same-week consecutive controls (prior TAVI, and subsequent TAVI) were provided. Outcomes of interest were procedural and long-term events, including death, myocardial infarction, stroke, access site complication, major bleeding, and reintervention, and their composite (i.e. major adverse events [MAE]). RESULTS: A total of 106 patients undergoing bailout TAVI-in-TAVI were included, as well as 212 controls, for a total of 318 individuals. Bailout TAVI-in-TAVI was less common in younger patients, those with higher body mass index, or treated with Portico/Navitor or Sapien devices (all p < 0.05). Bailout TAVI-in-TAVI was associated with higher in-hospital rates of death, emergency surgery, MAE, and permanent pacemaker implantation (all p < 0.05). Long-term follow-up showed that bailout TAVI-in-TAVI was associated with higher rates of death and MAE (both < 0.05). Similar findings were obtained at adjusted analyses (all p < 0.05). However, censoring early events, outlook was not significantly different when comparing the two groups (p = 0.897 for death, and p = 0.645 for MAE). CONCLUSIONS: Bail-out TAVI-in-TAVI is associated with significant early and long-term mortality and morbidity. Thus, meticulous preprocedural planning and sophisticated intraprocedural techniques are of paramount importance to avoid these emergency procedures.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia , Sistema de Registros , Valva Aórtica/cirurgia , Fatores de Risco
13.
Cardiovasc Revasc Med ; 62: 40-47, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38135568

RESUMO

BACKGROUND: Vascular complications (VCs) still represent one of the principal concerns of trans-femoral trans-catheter aortic valve replacement (TF-TAVR). New-generation devices can minimize such complications but the arterial access management is left to the operator's choice. This study aims to describe the rate of VCs in a contemporary cohort of patients undergoing TAVR with new-generation devices and to determine whether an ultrasound-guided (USG) vs. a fluoroscopy-guided (FG) femoral access management has an impact on their prevention. METHODS: This is a prospective, observational, multicenter study. Consecutive patients undergoing TAVR with new-generation devices were analyzed from January 2022 to October 2022 in five tertiary care centers. Femoral accesses were managed according to the operator's preferences. All the patients underwent a pre-discharge peripheral ultrasound control. VCs and bleedings were the main endpoints of interest. RESULTS: A total of 458 consecutive patients were enrolled (274 in the USG group and 184 in the FG group). VCs occurred in 6.5 % of the patients (5.2 % minor and 1.3 % major). There was no difference between the USG and the FG groups in terms of any VCs (7.3 % vs. 5.4 %; p = 0.4), or any VARC-3 bleedings (6.9 % vs 6 %, p = 0.9). At logistic regression analysis, the two guidance strategies did not result as predictors of VCs (odds Ratio 0.8, 95 % Confidence Interval 0.46-1.4; P = 0.4). CONCLUSIONS: In a contemporary cohort of patients undergoing TAVR with new-generation devices, the occurrence of VCs is low and mostly represented by minor VCs. USG and FG modalities did not affect the rate of VCs.


Assuntos
Valva Aórtica , Cateterismo Periférico , Artéria Femoral , Punções , Radiografia Intervencionista , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Ultrassonografia de Intervenção , Humanos , Artéria Femoral/diagnóstico por imagem , Masculino , Feminino , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Idoso , Fluoroscopia , Resultado do Tratamento , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Fatores de Risco , Radiografia Intervencionista/efeitos adversos , Próteses Valvulares Cardíacas , Fatores de Tempo , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Desenho de Prótese
14.
EuroIntervention ; 19(11): e926-e936, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37946539

RESUMO

BACKGROUND: In the context of primary mitral regurgitation (PMR), the selection of patients for transcatheter edge-to-edge repair (TEER) does not include a systematic assessment of PMR-associated cardiac remodelling. AIMS: We aimed to investigate the epidemiology and prognostic significance of different phenotypes of extra-mitral valve (MV) cardiac involvement in a large series of patients with PMR referred for TEER. METHODS: The study included 654 patients from the multicentre Italian GIOTTO registry, stratified into groups according to extra-mitral valve (MV) cardiac involvement. The primary endpoint was all-cause death at 2-year follow-up. RESULTS: Patients with no cardiac involvement (NI; n=58), left heart involvement (LHI; n=343) and right heart involvement (RHI; n=253) were analysed. Acute technical success was achieved in 98% of patients. Kaplan-Meier curve analysis revealed significantly worse survival in patients with LHI and RHI (p=0.041). On multivariate Cox regression analysis, extra-MV cardiac involvement, haemoglobin level and technical success were independent predictors of the primary endpoint occurrence. CONCLUSIONS: Grading cardiac involvement may help refine risk stratification, since at least 1 group of extra-MV cardiac involvement represents in itself a negative predictor of midterm outcome.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estimativa de Kaplan-Meier , Análise Multivariada , Pacientes , Resultado do Tratamento , Cateterismo Cardíaco
16.
J Am Heart Assoc ; 12(17): e029553, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37646211

RESUMO

Background There is little evidence about the prognostic role of mitral regurgitation (MR) in patients with low-flow, low-gradient aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). The aim of this study was to assess the prevalence and outcome implications of MR severity in patients with low-flow, low-gradient aortic stenosis undergoing TAVR, and to evaluate whether MR improvement after TAVR could influence clinical outcome. Methods and Results This study included consecutive patients with low-flow, low-gradient aortic stenosis undergoing TAVR at 2 Italian high-volume centers. The study population was categorized according to the baseline MR severity and to the presence of MR improvement at discharge. The primary outcome was the composite of all-cause death and hospitalization for worsening heart failure up to 1 year. The study included 268 patients; 57 (21%) patients showed MR >2+. Patients with MR >2+ showed a lower 1-year survival free from the primary outcome (P<0.001), all-cause death (P<0.001), and heart failure hospitalization (P<0.001) compared with patients with MR ≤2+. At multivariable analysis, baseline MR >2+ was an independent predictor of the primary outcome (P<0.001). Among patients with baseline MR >2+, MR improvement was reported in 24 (44%) cases after TAVR. The persistence of MR was associated with a significantly reduced survival free from the primary outcome, all-cause death, and heart failure hospitalization up to 1 year. Conclusions In this study, the presence of moderately severe to severe MR in patients with low-flow, low-gradient aortic stenosis undergoing TAVR portends a worse clinical outcome at 1 year. TAVR may improve MR severity in nearly half of the patients, resulting in a potential outcome benefit after discharge.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Prognóstico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia
17.
JACC Cardiovasc Interv ; 16(16): 1974-1985, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37648345

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with pure severe native aortic valve regurgitation (NAVR) has been associated with suboptimal results. The available evidence concerns mostly outdated transcatheter heart valves (THVs). OBJECTIVES: The aim of this study was to investigate the performance of new-generation THVs in patients treated for pure severe NAVR. METHODS: The PANTHEON (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve) study retrospectively included patients who underwent TAVR with currently available devices (both self-expanding [SE] and balloon expandable [BE]) for severe NAVR. Technical and device success rates as well as a composite of all-cause mortality and heart failure rehospitalization at 1 year were evaluated. The rate and clinical consequences of acute transcatheter valve embolization or migration (TVEM) were also considered. RESULTS: A total of 201 patients were included. Overall technical and device success rates were 83.6% and 76.1%, respectively, and did not differ between SE and BE devices. These figures were due mostly to TVEM occurrence (14.6% vs 16.1%; P = 0.47) and residual moderate or greater aortic regurgitation (9.2% vs 10.1%; P = 0.87). Patients who experienced TVEM compared with those without TVEM had a significantly higher incidence of the composite endpoint at 1 year (25.7% vs 15.8%; P = 0.05). CONCLUSIONS: Despite improved THV platforms and techniques, TAVR for pure severe NAVR remains a challenging procedure, with significant risk for TVEM. SE and BE platforms demonstrated comparable performance in this setting. (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve [PANTHEON]; NCT05319171).


Assuntos
Insuficiência da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
18.
Am J Cardiol ; 201: 349-358, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37423004

RESUMO

Transcatheter aortic valve replacement (TAVR) is an established therapy for severe, symptomatic aortic valve stenosis even in patients with impaired left ventricular systolic function. However, there is uncertainty on the clinical effectiveness of the currently available TAVR devices in patients with reduced left ventricular ejection fraction (LVEF). The LOSTAVI (Low Systolic function and Transcatheter Aortic Valve Implantation) registry is a retrospective observational study using baseline, procedural, discharge, and long-term follow-up details. A total of 3 groups of interest were distinguished: extremely reduced LVEF (<25%), severely reduced LVEF (25% to 30%), and reduced LVEF (31% to 35%). Unadjusted and adjusted analyses were carried out for in-hospital and follow-up outcomes. A total of 923 patients were included from 12 centers, with 146 patients (16%) with LVEF <25%, 425 (46%) with LVEF 25% to 30%, and 352 (38%) with LVEF 31% to 35%. Several baseline and procedural features were different across groups, including age, risk, functional class, and prevalence of bicuspid disease (all p <0.05). In-hospital mortality was similar in the 3 groups (7 [4.8%], 18 [4.2%], and 7 [2.0%], respectively, p = 0.661), but major adverse events were more common in those with extremely reduced and severely reduced LVEF (19 [13%], 53 [13%], and 25 [7.1%], respectively, p = 0.024). The 12-month follow-up confirmed the significant detrimental impact of reduced LVEF on both death (21 [14%], 49 [12%], and 25 [7.1%], respectively, p = 0.024) and major adverse events (37 [25%], 89 [21%], and 53 [15%], respectively, p = 0.016). The adjusted analysis confirmed the significant prognostic role of LVEF on both outcomes, whereas TAVR device type was not associated with death or major adverse events (all p >0.05). In conclusion, TAVR yields favorable early and 1-year results in patients with reduced LVEF, including those with extremely depressed systolic dysfunction. However, reduced LVEF still represents a major adverse prognostic factor for both short- and mid-term outcomes.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Função Ventricular Esquerda , Substituição da Valva Aórtica Transcateter/métodos , Volume Sistólico , Resultado do Tratamento , Sistema de Registros , Estudos Retrospectivos , Valva Aórtica/cirurgia
19.
Sci Rep ; 13(1): 10685, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37393369

RESUMO

Cangrelor, the first intravenous P2Y12 inhibitor (P2Y12-I), has been approved on the basis of three large RCTs from the CHAMPION program which nevertheless have been criticized for the low bleeding risk of the enrolled patients, the large quote of chronic coronary syndromes, and the use of Clopidogrel as control arm even in the setting of acute coronary syndromes (ACS). We sought to investigate, in the setting of ACS, the comparative performance of Cangrelor in terms of in-hospital ischemic and haemorrhagic outcomes compared with the current gold-standard of oral P2Y12-I. The study retrospectively enrolled 686 consecutive patients admitted to the Divisions of Cardiology of Policlinico of Bari and L. Bonomo Hospital of Andria for ACS and treated with percutaneous coronary intervention. The study population was divided according to the P2Y12-I treatment strategy in two groups: patients given an oral P2Y12-I and patients receiving Cangrelor in the cath lab followed by an oral P2Y12-I. Clinical endpoints included death, ischemic and bleeding events occurring during hospital stay. Cangrelor treated patients presented higher clinical risk profile at presentation and faced higher death rate. However, after PS matching, in-hospital mortality resulted comparable between the groups and Cangrelor use was associated with reduced in-hospital definite stent thrombosis (p = 0.03). Data from our real-world registry highlight that, in the setting of ACS, Cangrelor is prevalently used in patients with very challenging clinical presentations. The adjusted analysis provides for the first time promising data on stent thrombosis reduction associated with Cangrelor use.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Humanos , Síndrome Coronariana Aguda/cirurgia , Estudos Retrospectivos , Sistema de Registros
20.
J Am Heart Assoc ; 12(13): e029735, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37345813

RESUMO

Background Little is known about the impact of transcatheter mitral valve edge-to-edge repair on changes in left ventricular ejection fraction (LVEF) and the effect of an acute reduction in LVEF on prognosis. We aimed to assess changes in LVEF after transcatheter mitral valve edge-to-edge repair for both primary and secondary mitral regurgitation (PMR and SMR, respectively), identify rates and predictors of LVEF reduction, and estimate its impact on prognosis. Methods and Results In this international multicenter registry, patients with both PMR and SMR undergoing transcatheter mitral valve edge-to-edge repair were included. We assessed rates of acute LVEF reduction (LVEFR), defined as an acute relative decrease of >15% in LVEF, its impact on all-cause mortality, major adverse cardiac event (composite end point of all-cause death, mitral valve surgery, and residual mitral regurgitation grade ≥2), and LVEF at 12 months, as well as predictors for LVEFR. Of 2534 patients included (727 with PMR, and 1807 with SMR), 469 (18.5%) developed LVEFR. Patients with PMR were older (79.0±9.2 versus 71.8±8.9 years; P<0.001) and had higher mean LVEF (54.8±14.0% versus 32.7±10.4%; P<0.001) at baseline. After 6 to 12 months (median, 9.9 months; interquartile range, 7.8-11.9 months), LVEF was significantly lower in patients with PMR (53.0% versus 56.0%; P<0.001) but not in patients with SMR. The 1-year mortality was higher in patients with PMR with LVEFR (16.9% versus 9.7%; P<0.001) but not in those with SMR (P=0.236). LVEF at baseline (odds ratio, 1.03 [95% CI, 1.01-1.05]; P=0.002) was predictive of LVEFR for patients with PMR, but not those with SMR (P=0.092). Conclusions Reduction in LVEF is not uncommon after transcatheter mitral valve edge-to-edge repair and is correlated with worsened prognosis in patients with PMR but not patients with SMR. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT05311163.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Função Ventricular Esquerda , Volume Sistólico , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...