Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 63(16): 4226-4233, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38856597

RESUMO

The real-time monitoring of densely populated areas with high seismic and volcanic risk is of crucial importance for the safety of people and infrastructures. When an earthquake occurs, the Earth surface experiences both translational and rotational motions. The latter are usually not monitored, but their measurement and characterization are essential for a full description of the ground motion. Here we present preliminary observational data of a high-sensitivity rotational sensor based on a 2-km-long fiber-optic Sagnac gyroscope, presently under construction in the middle of the Campi Flegrei Volcanic Area (Pozzuoli, Italy). We have evaluated its performance by analyzing data continuously recorded during an acquisition campaign of five months. The experimental setup was composed of a digital nine-component seismic station equipped with both a rotational sensor and conventional seismic sensors (seismometers, accelerometers, and tiltmeters). During this experiment we detected seismic noise and ground rotations wavefield induced by small to medium local earthquakes (M D<3). The prototype gyroscope shows a very promising sensitivity in the range of 5×10-7-8×10-9 r a d/s/H z over the frequency bandwidth 5 mHz-50 Hz. Future upgrades and perspectives are discussed.

2.
Opt Express ; 32(4): 5353-5361, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38439264

RESUMO

Portable optical spectrometers are crucial devices for bio-chemical sensing and spectroscopic applications whereby robust, compact and cost-effective set-ups are desirable. However, existing miniaturized instruments typically struggle to achieve broad wavelength operation and high spectral resolution at the same time. Here, an all-fiber optical spectrometer based on two cascaded Bragg gratings is devised and demonstrated, showing a record resolution and a wavelength span-to-resolution ratio larger than that of most miniature broadband spectrometers reported to date. Thanks to a synchronous control of the grating lengths and to a unique combination of their reflection features, spectral analysis of incoherent light within 1 pm is achieved. On the other hand, fast and reproducible wavelength tuning over several nanometers on a millisecond-timescale is ensured by mechanical stretching of the internal fiber, limited only by the actuator's dynamic range. A striking evidence of the spectrometer capabilities is provided with Doppler-limited spectroscopy of gas absorption bands performed with a near-infrared LED source. The observed spectra exhibit lineshapes comparable with those obtained by laser-based set-ups and the retrieved gas-line parameters are in agreement with existing spectroscopic databases. The spectrometer lends itself to applications in high-resolution interrogation of multiple fiber-optic sensors as well as broadband imaging with supercontinuum light.

3.
Sensors (Basel) ; 23(21)2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37960705

RESUMO

Whispering-gallery mode microresonators have gained wide popularity as experimental platforms for different applications, ranging from biosensing to nonlinear optics. Typically, the resonant modes of dielectric microresonators are stimulated via evanescent wave coupling, facilitated using tapered optical fibers or coupling prisms. However, this method poses serious shortcomings due to fabrication and access-related limitations, which could be elegantly overcome by implementing a free-space coupling approach; although additional alignment procedures are needed in this case. To address this issue, we have developed a new algorithm to excite the microresonator automatically. Here, we show the working mechanism and the preliminary results of our experimental method applied to a home-made silica microsphere, using a visible laser beam with a spatial light modulator and a software control.

4.
Sensors (Basel) ; 19(3)2019 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-30682798

RESUMO

We provide here an overview of passive optical micro-cavities made of droplets in the liquid phase. We focus on resonators that are naturally created and suspended under gravity thanks to interfacial forces, illustrating simple ways to excite whispering-gallery modes in various slow-evaporation liquids using free-space optics. Similar to solid resonators, frequency locking of near-infrared and visible lasers to resonant modes is performed exploiting either phase-sensitive detection of the leakage cavity field or multiple interference between whispering-gallery modes in the scattered light. As opposed to conventional micro-cavity sensors, each droplet acts simultaneously as the sensor and the sample, whereby the internal light can detect dissolved compounds and particles. Optical quality factors up to 107⁻108 are observed in liquid-polymer droplets through photon lifetime measurements. First attempts in using single water droplets are also reported. These achievements point out their huge potential for direct spectroscopy and bio-chemical sensing in liquid environments. Finally, the first experiments of cavity optomechanics with surface acoustic waves in nanolitre droplets are presented. The possibility to perform studies of viscous-elastic properties points to a new paradigm: a droplet device as an opto-fluid-mechanics laboratory on table-top scale under controlled environmental conditions.

5.
Sensors (Basel) ; 15(2): 4242-52, 2015 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-25686311

RESUMO

The measurement of ionizing radiation (IR) is a crucial issue in different areas of interest, from environmental safety and industrial monitoring to aerospace and medicine. Optical fiber sensors have recently proven good candidates as radiation dosimeters. Here we investigate the effect of IR on germanosilicate optical fibers. A piece of Ge-doped fiber enclosed between two fiber Bragg gratings (FBGs) is irradiated with gamma radiation generated by a 6 MV medical linear accelerator. With respect to other FBG-based IR dosimeters, here the sensor is only the bare fiber without any special internal structure. A near infrared laser is frequency locked to the cavity modes for high resolution measurement of radiation induced effects on the fiber optical parameters. In particular, we observe a variation of the fiber thermo-optic response with the radiation dose delivered, as expected from the interaction with Ge defect centers, and demonstrate a detection limit of 360 mGy. This method can have an impact in those contexts where low radiation doses have to be measured both in small volumes or over large areas, such as radiation therapy and radiation protection, while bare optical fibers are cheap and disposable.


Assuntos
Tecnologia de Fibra Óptica/métodos , Fibras Ópticas , Radiação Ionizante
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...