Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neurophotonics ; 10(4): 045003, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37841558

RESUMO

Significance: Critically ill newborns are at risk of brain damage from cerebrovascular disturbances. A cerebral hemodynamic monitoring system would have the potential role to guide targeted intervention. Aim: To obtain, in a population of newborn infants, simultaneous near-infrared spectroscopy (NIRS)-based estimates of cerebral tissue oxygen saturation (StO2) and blood flow during variations of carbon dioxide tension (pCO2) levels within physiologic values up to moderate permissive hypercapnia, and to examine if the derived estimate of metabolic rate of oxygen would stay constant, during the same variations. Approach: We enrolled clinically stable mechanically ventilated newborns at postnatal age >24 h without brain abnormalities at ultrasound. StO2 and blood flow index were measured using a non-invasive device (BabyLux), which combine time-resolved NIRS and diffuse-correlation spectroscopy. The effect of changes in transcutaneous pCO2 on StO2, cerebral blood flow (CBF), and cerebral metabolic rate of oxygen index (tCMRO2i) were estimated. Results: Ten babies were enrolled and three were excluded. Median GA at enrollment was 39 weeks and median weight 2720 g. StO2 increased 0.58% (95% CI 0.55; 0.61, p<0.001), CBF 2% (1.9; 2.3, p<0.001), and tCMRO2 0.3% (0.05; 0.46, p=0.017) per mmHg increase in pCO2. Conclusions: BabyLux device detected pCO2-induced changes in cerebral StO2 and CBF, as expected. The small statistically significant positive relationship between pCO2 and tCMRO2i variation is not considered clinically relevant and we are inclined to consider it as an artifact.

2.
Dev Cogn Neurosci ; 57: 101148, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36027649

RESUMO

Sensory prediction (SP) is at the core of early cognitive development. Impaired SP may be a key to understanding the emergence of neurodevelopmental disorders, however there is little data on how and when this skill emerges. We set out to provide evidence of SP in the brain of premature neonates in the fundamental sensory modality: touch. Using Diffuse Correlation Spectroscopy, we measured blood flow changes in the somatosensory cortex of premature neonates presented with a vibrotactile stimulation-omission sequence. When ISI was fixed, participants presented a decrease in blood flow during stimulus omissions, starting when a stimulus should begin: the expectation of a certain stimulus onset induced deactivation of the somatosensory cortex. When ISI was jittered, we observed an increase in blood flow during omissions: the expectation of a likely but not certain stimulus onset induced activation of the somatosensory cortex. Our results reveal SP in the brain as early as four weeks before term, based on the temporal structure of a unimodal somatosensory stimulation, and show that SP produces opposite regulation of activity in the somatosensory cortex depending on how liable is stimulus onset. Future studies will investigate the predictive value of somatosensory prediction on neurodevelopment in this vulnerable population.

3.
Biomed Opt Express ; 12(7): 4235-4248, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34457411

RESUMO

A practical assessment of the general health and microvascular function of the palm muscle, abductor pollicis brevis (APB), is important for the diagnosis of different conditions. In this study, we have developed a protocol and a probe to study microvascular blood flow using near-infrared diffuse correlation spectroscopy (DCS) in APB during and after thumb abduction at 55% of maximum voluntary contraction (MVC). Near-infrared time resolved spectroscopy (TRS) was also used to characterize the baseline optical and hemodynamic properties. Thirteen (n=13) subjects were enrolled and subdivided in low MVC (N=6, MVC<2.3 kg) and high MVC (N=7, MVC≥2.3 kg) groups. After ruling out significant changes in the systemic physiology that influence the muscle hemodynamics, we have observed that the high MVC group showed a 56% and 36% decrease in the blood flow during exercise, with respect to baseline, in the long and short source-detector (SD) separations (p=0.031 for both). No statistical differences were shown for the low MVC group (p=1 for short and p=0.15 for long SD). These results suggest that the mechanical occlusion, due to increased intramuscular pressure, exceeded the vasodilation elicited by the higher metabolic demand. Also, blood flow changes during thumb contraction negatively correlated (R=-0.7, p<0.01) with the absolute force applied by each subject. Furthermore, after the exercise, muscular blood flow increased significantly immediately after thumb contractions in both high and low MVC groups, with respect to the recorded values during the exercise (p=0.031). An increase of 251% (200%) was found for the long (short) SD in the low MVC group. The high MVC groups showed a significant 90% increase in blood flow only after 80 s from the start of the protocol. For both low and high MVC groups, blood flow recovered to baseline values within 160 s from starting the exercise. In conclusion, DCS allows the study of the response of a small muscle to static exercise and can be potentially used in multiple clinical conditions scenarios for assessing microvascular health.

4.
Biomed Opt Express ; 12(6): 3265-3281, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34221659

RESUMO

Over the recent years, a typical implementation of diffuse correlation spectroscopy (DCS) instrumentation has been adapted widely. However, there are no detailed and accepted recipes for designing such instrumentation to meet pre-defined signal-to-noise ratio (SNR) and precision targets. These require specific attention due to the subtleties of the DCS signals. Here, DCS experiments have been performed using liquid tissue simulating phantoms to study the effect of the detected photon count-rate, the number of parallel detection channels and the measurement duration on the precision and SNR to suggest scaling relations to be utilized for device design.

5.
J Cereb Blood Flow Metab ; 40(10): 2055-2065, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-31665953

RESUMO

Diffuse correlation spectroscopy (DCS) can non-invasively and continuously asses regional cerebral blood flow (rCBF) at the cot-side by measuring a blood flow index (BFI) in non-traditional units of cm2/s. We have validated DCS against positron emission tomography using 15O-labeled water (15O-water PET) in a piglet model allowing us to derive a conversion formula for BFI to rCBF in conventional units (ml/100g/min). Neonatal piglets were continuously monitored by the BabyLux device integrating DCS and time resolved near infrared spectroscopy (TRS) while acquiring 15O-water PET scans at baseline, after injection of acetazolamide and during induced hypoxic episodes. BFI by DCS was highly correlated with rCBF (R = 0.94, p < 0.001) by PET. A scaling factor of 0.89 (limits of agreement for individual measurement: 0.56, 1.39)×109× (ml/100g/min)/(cm2/s) was used to derive baseline rCBF from baseline BFI measurements of another group of piglets and of healthy newborn infants showing an agreement with expected values. These results pave the way towards non-invasive, cot-side absolute CBF measurements by DCS on neonates.


Assuntos
Circulação Cerebrovascular/fisiologia , Tomografia por Emissão de Pósitrons/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Acetazolamida/farmacologia , Animais , Animais Recém-Nascidos , Diuréticos/farmacologia , Humanos , Hipóxia/fisiopatologia , Processamento de Imagem Assistida por Computador , Recém-Nascido , Radioisótopos de Oxigênio , Compostos Radiofarmacêuticos , Suínos
6.
Pediatr Res ; 86(4): 515-521, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31234195

RESUMO

BACKGROUND: The BabyLux device is a prototype optical neuro-monitor of cerebral oxygenation and blood flow for neonatology integrating time-resolved reflectance spectroscopy and diffuse correlation spectroscopy. METHODS: Here we report the variability of six consecutive 30 s measurements performed in 27 healthy term infants at rest. Poor data quality excluded four infants. RESULTS: Mean cerebral oxygenation was 59.6 ± 8.0%, with intra-subject standard deviation of 3.4%, that is, coefficient of variation (CV) of 5.7%. The inter-subject CV was 13.5%. Mean blood flow index was 2.7 × 10-8 ± 1.56 × 10-8 (cm2/s), with intra-subject CV of 27% and inter-subject CV of 56%. The variability in blood flow index was not reduced by the use of individual measures of tissue scattering, nor accompanied by a parallel variability in cerebral oxygenation. CONCLUSION: The intra-subject variability for cerebral oxygenation variability was improved compared to spatially resolved spectroscopy devices, while for the blood flow index it was comparable to that of other modalities for estimating cerebral blood flow in newborn infants. Most importantly, the simultaneous measurement of oxygenation and flow allows for interpretation of the high inter-subject variability of cerebral blood flow as being due to error of measurement rather than to physiological instability.


Assuntos
Circulação Cerebrovascular , Neonatologia/instrumentação , Consumo de Oxigênio , Oxigênio/sangue , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Encéfalo/fisiologia , Desenho de Equipamento , Hemodinâmica , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Monitorização Fisiológica/instrumentação , Reprodutibilidade dos Testes
7.
Biomed Opt Express ; 10(5): 2556-2579, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-31149383

RESUMO

We have investigated the accuracy and precision of "the BabyLux device", a hybrid time-resolved near-infrared (TRS) and diffuse correlation spectroscopy (DCS) neuro-monitor for the pre-term infant. Numerical data with realistic noise were simulated and analyzed using the BabyLux device as a reference system and different experimental and analysis parameters. The results describe the limits for the precision and the accuracy to be expected. The dependence of these limits on different experimental conditions and choices of the analysis method is also described. Experiments demonstrate comparable values for precision with respect to the simulation results.

8.
Neurophotonics ; 6(2): 025007, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31093515

RESUMO

The BabyLux device is a hybrid diffuse optical neuromonitor that has been developed and built to be employed in neonatal intensive care unit for the noninvasive, cot-side monitoring of microvascular cerebral blood flow and blood oxygenation. It integrates time-resolved near-infrared and diffuse correlation spectroscopies in a user-friendly device as a prototype for a future medical grade device. We present a thorough characterization of the device performance using test measurements in laboratory settings. Tests on solid phantoms report an accuracy of optical property estimation of about 10%, which is expected when using the photon diffusion equation as the model. The measurement of the optical and dynamic properties is stable during several hours of measurements within 3% of the average value. In addition, these measurements are repeatable between different days of measurement, showing a maximal variation of 5% in the optical properties and 8% for the particle diffusion coefficient on a liquid phantom. The variability over test/retest evaluation is < 3 % . The integration of the two modalities is robust and without any cross talk between the two. We also perform in vivo measurements on the adult forearm during arterial cuff occlusion to show that the device can measure a wide range of tissue hemodynamic parameters. We suggest that this platform can form the basis of the next-generation neonatal neuromonitors to be developed for extensive, multicenter clinical testing.

9.
Arch Dis Child Fetal Neonatal Ed ; 104(6): F648-F653, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31085677

RESUMO

OBJECTIVES: A new device that combines, for the first time, two photonic technologies (time-resolved near-infrared spectroscopy and diffuse correlation spectroscopy) was provided and tested within the BabyLux project. Aim was to validate the expected changes in cerebral oxygenation and blood flow. METHODS: A pulse oximeter and the BabyLux device were held in place (right hand/wrist and frontoparietal region, respectively) for 10 min after birth in healthy term infants delivered by elective caesarean section. Pulse oximeter saturation (SpO2), cerebral tissue oxygen saturation (StO2) and blood flow index (BFI) were measured over time. Tissue oxygen extraction (TOE) and cerebral metabolic rate of oxygen index (CMRO2I) were calculated. RESULTS: Thirty infants were enrolled in two centres. After validity check of data, 23% of infants were excluded from TOE and CMRO2I calculation due to missing data. As expected, SpO2 (estimate 3.05 %/min; 95% CI 2.78 to 3.31 %/min) and StO2 (estimate 3.95 %/min; 95% CI 3.63 to 4.27 %/min) increased in the first 10 min after birth, whereas BFI (estimate -2.84×10-9 cm2/s/min; 95% CI -2.50×10-9 to -3.24×10-9 cm2/s/min) and TOE (estimate -0.78 %/min; 95% CI -1.12 to -0.45 %/min) decreased. Surprisingly, CMRO2I decreased (estimate -7.94×10-8/min; 95% CI -6.26×10-8 to -9.62×10-8/min). CONCLUSIONS: Brain oxygenation and BFI during transition were successfully and simultaneously obtained by the BabyLux device; no adverse effects were recorded, and the BabyLux device did not limit the standard care. The preliminary results from clinical application of the BabyLux device are encouraging in terms of safety and feasibility; they are consistent with previous reports on brain oxygenation during transition, although the interpretation of the decreasing CMRO2I remains open. TRIAL REGISTRATION NUMBER: NCT02815618.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Oxigênio/sangue , Análise Espectral/instrumentação , Encéfalo/metabolismo , Cesárea , Feminino , Hemodinâmica , Humanos , Recém-Nascido , Masculino , Oximetria , Espectroscopia de Luz Próxima ao Infravermelho
10.
PLoS One ; 13(3): e0194204, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29538409

RESUMO

MOTIVATION: Obstructive sleep apnea (OSA) can impair cerebral vasoreactivity and is associated with an increased risk of cerebrovascular disease. Unfortunately, an easy-to-use, non-invasive, portable monitor of cerebral vasoreactivity does not exist. Therefore, we have evaluated the use of near-infrared diffuse correlation spectroscopy to measure the microvascular cerebral blood flow (CBF) response to a mild head-of-bed position change as a biomarker for the evaluation of cerebral vasoreactivity alteration due to chronic OSA. Furthermore, we have monitored the effect of two years of continuous positive airway pressure (CPAP) treatment on the cerebral vasoreactivity. METHODOLOGY: CBF was measured at different head-of-bed position changes (supine to 30° to supine) in sixty-eight patients with OSA grouped according to severity (forty moderate to severe, twenty-eight mild) and in fourteen control subjects without OSA. A subgroup (n = 13) with severe OSA was measured again after two years of CPAP treatment. RESULTS: All patients and controls showed a similar CBF response after changing position from supine to 30° (p = 0.819), with a median (confidence interval) change of -17.5 (-10.3, -22.9)%. However, when being tilted back to the supine position, while the control group (p = 0.091) and the mild patients with OSA (p = 0.227) recovered to the initial baseline, patients with moderate and severe OSA did not recover to the baseline (9.8 (0.8, 12.9)%, p < 0.001) suggesting altered cerebral vasoreactivity. This alteration was correlated with OSA severity defined by the apnea-hypopnea index, and with mean nocturnal arterial oxygen saturation. The CBF response was normalized after two years of CPAP treatment upon follow-up measurements. CONCLUSION: In conclusion, microvascular CBF response to a head-of-bed challenge measured by diffuse correlation spectroscopy suggests that moderate and severe patients with OSA have altered cerebral vasoreactivity related to OSA severity. This may normalize after two years of CPAP treatment.


Assuntos
Circulação Cerebrovascular , Microcirculação , Apneia Obstrutiva do Sono/fisiopatologia , Adulto , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva , Apneia Obstrutiva do Sono/terapia , Decúbito Dorsal
11.
Neurophotonics ; 5(1): 015001, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29392156

RESUMO

Transcranial direct current stimulation (tDCS) is currently being used for research and treatment of some neurological and neuropsychiatric disorders, as well as for improvement of cognitive functions. In order to better understand cerebral response to the stimulation and to redefine protocols and dosage, its effects must be monitored. To this end, we have used functional diffuse correlation spectroscopy (fDCS) and time-resolved functional near-infrared spectroscopy (TR-fNIRS) together with electroencephalography (EEG) during and after stimulation of the frontal cortex. Twenty subjects participated in two sessions of stimulation with two different polarity montages and twelve also underwent a sham session. Cerebral blood flow and oxyhemoglobin concentration increased during and after active stimulation in the region under the stimulation electrode while deoxyhemoglobin concentration decreased. The EEG spectrum displayed statistically significant power changes across different stimulation sessions in delta (2 to 4 Hz), theta (4 to 8 Hz), and beta (12 to 18 Hz) bands. Results suggest that fDCS and TR-fNIRS can be employed as neuromonitors of the effects of transcranial electrical stimulation and can be used together with EEG.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...