Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Clin Invest ; 53(1): e13862, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36004486

RESUMO

BACKGROUND: The number of patients with cardiac implantable electronic devices (CIEDs) undergoing radiotherapy (RT) for cancer treatment is growing. At present, prevalence and predictors of RT-induced CIEDs malfunctions are not defined. METHODS: Systematic review and meta-analysis conducted following the PRISMA recommendations. PubMed, Scopus and Google Scholar were searched from inception to 31/01/2022 for studies reporting RT-induced malfunctions in CIEDs patients. Aim was to assess the prevalence of RT-induced CIEDs malfunctions and identify potential predictors. RESULTS: Thirty-two out of 3962 records matched the inclusion criteria and were included in the meta-analysis. A total of 135 CIEDs malfunctions were detected among 3121 patients (6.6%, 95% confidence interval [CI]: 5.1%-8.4%). The pooled prevalence increased moving from pacemaker (PM) to implantable cardioverter defibrillator (ICD), and cardiac resynchronization therapy and defibrillator (CRT-D) groups (4.1%, 95% CI: 2.9-5.8; 8.2% 95% CI: 5.9-11.3; and 19.8%, 95% CI: 11.4-32.2 respectively). A higher risk ratio (RR) of malfunctions was found when neutron-producing energies were used as compared to non-neutron-producing energies (RR 9.98, 95% CI: 5.09-19.60) and in patients with ICD/CRT-D as compared to patients with PM/CRT-P (RR 2.07, 95% CI: 1.40-3.06). On the contrary, no association was found between maximal radiation dose at CIED >2 Gy and CIEDs malfunctions (RR 0.93; 95% CI: 0.31-2.76). CONCLUSIONS: Radiotherapy related CIEDs malfunction had a prevalence ranging from 4% to 20%. The use of neutron-producing energies and more complex devices (ICD/CRT-D) were associated with higher risk of device malfunction, while the radiation dose at CIED did not significantly impact on the risk unless higher doses (>10 Gy) were used.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos
2.
Vet Parasitol ; 149(3-4): 271-4, 2007 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-17764846

RESUMO

A cross-sectional serological survey was conducted in order to evaluate, irrespective of abortion, the Toxoplasma gondii infection in pastured sheep from the Campania region of southern Italy. A geographical information system was used in order to uniformly sample the ovine farms (n=117) throughout the entire region. Blood and milk samples were collected from 10 adult sheep (>18 months) on each farm (total number=1170 sheep). Serum samples were tested for the presence of IgG antibodies to T. gondii using a commercial indirect fluorescent antibody test. For each farm, the 10 milk samples collected were pooled in order to obtain a single milk sample per farm (total number=117 milk samples). The 77.8% (91/117) of the farms and the 28.5% (333/11,170) of the sheep resulted positive by serology. In addition, the presence of T. gondii DNA was detected by PCR in 4 milk samples out of the 117 examined (3.4%).


Assuntos
Doenças dos Ovinos/epidemiologia , Doenças dos Ovinos/parasitologia , Toxoplasma , Toxoplasmose Animal/epidemiologia , Animais , Genes de Protozoários , Itália/epidemiologia , Estudos Soroepidemiológicos , Ovinos , Doenças dos Ovinos/sangue , Toxoplasma/genética , Toxoplasmose Animal/sangue , Toxoplasmose Animal/parasitologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...