Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JCI Insight ; 8(16)2023 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-37606046

RESUMO

BACKGROUNDWhile B cell depletion is associated with attenuated antibody responses to SARS-CoV-2 mRNA vaccination, responses vary among individuals. Thus, elucidating the factors that affect immune responses after repeated vaccination is an important clinical need.METHODSWe evaluated the quality and magnitude of the T cell, B cell, antibody, and cytokine responses to a third dose of BNT162b2 or mRNA-1273 mRNA vaccine in patients with B cell depletion.RESULTSIn contrast with control individuals (n = 10), most patients on anti-CD20 therapy (n = 48) did not demonstrate an increase in spike-specific B cells or antibodies after a third dose of vaccine. A third vaccine elicited significantly increased frequencies of spike-specific non-naive T cells. A small subset of B cell-depleted individuals effectively produced spike-specific antibodies, and logistic regression models identified time since last anti-CD20 treatment and lower cumulative exposure to anti-CD20 mAbs as predictors of those having a serologic response. B cell-depleted patients who mounted an antibody response to 3 vaccine doses had persistent humoral immunity 6 months later.CONCLUSIONThese results demonstrate that serial vaccination strategies can be effective for a subset of B cell-depleted patients.FUNDINGThe NIH (R25 NS079193, P01 AI073748, U24 AI11867, R01 AI22220, UM 1HG009390, P01 AI039671, P50 CA121974, R01 CA227473, U01CA260507, 75N93019C00065, K24 AG042489), NIH HIPC Consortium (U19 AI089992), the National Multiple Sclerosis Society (CA 1061-A-18, RG-1802-30153), the Nancy Taylor Foundation for Chronic Diseases, Erase MS, and the Claude D. Pepper Older Americans Independence Center at Yale (P30 AG21342).


Assuntos
Formação de Anticorpos , COVID-19 , Humanos , Idoso , SARS-CoV-2 , Vacina BNT162 , COVID-19/prevenção & controle , Vacinação , Anticorpos Monoclonais , Soro Antilinfocitário , RNA Mensageiro
2.
Small Methods ; 7(10): e2300594, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37312418

RESUMO

How to develop highly informative serology assays to evaluate the quality of immune protection against coronavirus disease-19 (COVID-19) has been a global pursuit over the past years. Here, a microfluidic high-plex immuno-serolomic assay is developed to simultaneously measure50 plasma or serum samples for50 soluble markers including 35proteins, 11 anti-spike/receptor binding domian (RBD) IgG antibodies spanningmajor variants, and controls. This assay demonstrates the quintuplicate test in a single run with high throughput, low sample volume, high reproducibilityand accuracy. It is applied to the measurement of 1012 blood samples including in-depth analysis of sera from 127 patients and 21 healthy donors over multiple time points, either with acute COVID infection or vaccination. The protein analysis reveals distinct immune mediator modules that exhibit a reduced degree of diversity in protein-protein cooperation in patients with hematologic malignancies or receiving B cell depletion therapy. Serological analysis identifies that COVID-infected patients with hematologic malignancies display impaired anti-RBD antibody response despite high level of anti-spike IgG, which can be associated with limited clonotype diversity and functional deficiency in B cells. These findings underscore the importance to individualize immunization strategies for these high-risk patients and provide an informative tool to monitor their responses at the systems level.


Assuntos
COVID-19 , Neoplasias Hematológicas , Vacinas , Humanos , COVID-19/prevenção & controle , Microfluídica , Imunoglobulina G
3.
bioRxiv ; 2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36093346

RESUMO

The immune response to SARS-CoV-2 for patients with altered immunity such as hematologic malignancies and autoimmune disease may differ substantially from that in general population. These patients remain at high risk despite wide-spread adoption of vaccination. It is critical to examine the differences at the systems level between the general population and the patients with altered immunity in terms of immunologic and serological responses to COVID-19 infection and vaccination. Here, we developed a novel microfluidic chip for high-plex immuno-serological assay to simultaneously measure up to 50 plasma or serum samples for up to 50 soluble markers including 35 plasma proteins, 11 anti-spike/RBD IgG antibodies spanning all major variants, and controls. Our assay demonstrated the quintuplicate test in a single run with high throughput, low sample volume input, high reproducibility and high accuracy. It was applied to the measurement of 1,012 blood samples including in-depth analysis of sera from 127 patients and 21 healthy donors over multiple time points, either with acute COVID infection or vaccination. The protein association matrix analysis revealed distinct immune mediator protein modules that exhibited a reduced degree of diversity in protein-protein cooperation in patients with hematologic malignancies and patients with autoimmune disorders receiving B cell depletion therapy. Serological analysis identified that COVID infected patients with hematologic malignancies display impaired anti-RBD antibody response despite high level of anti-spike IgG, which could be associated with limited clonotype diversity and functional deficiency in B cells and was further confirmed by single-cell BCR and transcriptome sequencing. These findings underscore the importance to individualize immunization strategy for these high-risk patients and provide an informative tool to monitor their responses at the systems level.

4.
J Clin Microbiol ; 58(11)2020 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-32817144

RESUMO

A total of 1,200 serum samples that were tested for SARS-CoV-2 IgG antibody using the Abbott Architect immunoassay targeting the nucleocapsid protein were run in 3 SARS-CoV-2 IgG immunoassays targeting spike proteins (DiaSorin Liaison, Ortho Vitros, and Euroimmun). Consensus-positive and consensus-negative interpretations were defined as qualitative agreement in at least 3 of the 4 assays. Agreement of the 4 individual assays with a consensus-negative interpretation (n = 610) ranged from 96.7% to 100%, and agreement with a consensus-positive interpretation (n = 584) ranged from 94.3% to 100%. Laboratory-developed inhibition assays were utilized to evaluate 49 consensus-negative samples that were positive in only one assay; true-positive reactivity was confirmed in only 2 of these 49 (4%) samples. These findings demonstrate very high levels of agreement among 4 SARS-CoV-2 IgG assays authorized for emergency use, regardless of antigen target or assay format. Although false-positive reactivity was identified, its occurrence was rare (no more than 1.7% of samples for a given assay).


Assuntos
Infecções por Coronavirus , Nucleocapsídeo , Pandemias , Pneumonia Viral , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave , Anticorpos Antivirais , Betacoronavirus , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico , Infecções por Coronavirus/diagnóstico , Humanos , Imunoensaio , Imunoglobulina G , SARS-CoV-2 , Sensibilidade e Especificidade , Glicoproteína da Espícula de Coronavírus
5.
J Immunol Methods ; 444: 24-28, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28216236

RESUMO

All sera initially reactive in the Focus Diagnostics West Nile virus IgM capture enzyme-linked immunosorbent assay (WNV IgM ELISA) must be retested with background subtraction to identify falsely-reactive (FR) samples due to antibodies that bind to immunoglobulins of other animal species (heterophilic antibodies). In some settings, such as pre-transplant testing of organ donors, the reporting delay associated with retesting can have an adverse impact on donor procurement and organ placement. We sought to determine if inclusion of heterophilic antibody blockers in assay conjugate could eliminate the nonspecific reactivity of FR samples. Of 6 blocking reagents evaluated using a well-characterized FR sample, immunoglobulin inhibiting reagent from Bioreclamation (IIR) and blocker from Fitzgerald Industries (BFI) were superior in their ability to inhibit false reactivity; these 2 blockers were then used to evaluate 20 additional FR and 21 truly-reactive (TR) samples. Both blockers eliminated the reactivity of 20/21 FR samples, whereas all 21 TR samples remained reactive; further, all 13 truly non-reactive (NR) samples evaluated remained non-reactive when using blocker-containing conjugate. A subset of 22 samples were tested in parallel using the initial lot and a second lot of IIR and BFI; with one exception, all samples showed the same qualitative result using both lots of a given blocker. These findings demonstrate that modification of the Focus WNV IgM screening ELISA to include heterophilic antibody blocker IIR or BFI in assay conjugate eliminates the reactivity of most FR samples, markedly reducing the number of samples requiring further testing by background subtraction.


Assuntos
Anticorpos Heterófilos/sangue , Anticorpos Antivirais/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Imunoglobulina M/sangue , Febre do Nilo Ocidental/diagnóstico , Vírus do Nilo Ocidental/imunologia , Especificidade de Anticorpos , Biomarcadores/sangue , Reações Falso-Negativas , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estados Unidos , Febre do Nilo Ocidental/sangue , Febre do Nilo Ocidental/imunologia , Febre do Nilo Ocidental/virologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...