Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Science ; 344(6179): 55-8, 2014 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-24674868

RESUMO

Rapid advances in DNA synthesis techniques have made it possible to engineer viruses, biochemical pathways and assemble bacterial genomes. Here, we report the synthesis of a functional 272,871-base pair designer eukaryotic chromosome, synIII, which is based on the 316,617-base pair native Saccharomyces cerevisiae chromosome III. Changes to synIII include TAG/TAA stop-codon replacements, deletion of subtelomeric regions, introns, transfer RNAs, transposons, and silent mating loci as well as insertion of loxPsym sites to enable genome scrambling. SynIII is functional in S. cerevisiae. Scrambling of the chromosome in a heterozygous diploid reveals a large increase in a-mater derivatives resulting from loss of the MATα allele on synIII. The complete design and synthesis of synIII establishes S. cerevisiae as the basis for designer eukaryotic genome biology.


Assuntos
Cromossomos Fúngicos , Saccharomyces cerevisiae/genética , Biologia Sintética/métodos , Sequência de Bases , Cromossomos Fúngicos/genética , Cromossomos Fúngicos/metabolismo , DNA Fúngico/genética , Genes Fúngicos , Aptidão Genética , Genoma Fúngico , Instabilidade Genômica , Íntrons , Dados de Sequência Molecular , Mutação , Reação em Cadeia da Polimerase , RNA Fúngico/genética , RNA de Transferência/genética , Saccharomyces cerevisiae/citologia , Saccharomyces cerevisiae/fisiologia , Análise de Sequência de DNA , Deleção de Sequência , Transformação Genética
3.
Int J Spine Surg ; 6: 1-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-25694863

RESUMO

BACKGROUND: Pure moment testing is a common method used in cadaveric spine testing. The fundamental basis for the widespread acceptance of applying a pure moment is uniform loading along the column of the spine. To our knowledge, this protocol has not been experimentally verified on a multi-degree of freedom testing apparatus. Given its ubiquitous use in spine biomechanics laboratories, confirmation of this comparative cadaveric test protocol is paramount. METHODS: Group A specimens (n =13) were used to test the pure moment protocol, by use of 3 constructs that changed the number of involved vertebrae, orientation, and rigidity of the spine construct. Group B specimens (n = 6) were used to determine whether potting orientation, testing order, or degradation affected the range of motion (ROM) by use of 8 constructs. Each group was subjected to 3 cycles of flexion-extension, lateral bending, and axial torsion. The data from the third cycle were used to calculate the ROM for each method. RESULTS: Group A testing resulted in significant differences in ROM across the 3 constructs for lateral bending and axial torsion (P < .02) and trended toward a difference for flexion-extension (P = .055). Group B testing showed an increase in ROM across 8 constructs (P < .04) but no significant difference due to the orientation change. CONCLUSION: The increased ROM across constructs observed in both groups indicates that the cause is likely the testing order or degradation of the specimens, with orientation having no observed effect. The data do not invalidate pure moment testing, and its use should persist.

4.
Int J Spine Surg ; 6: 167-73, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-25694886

RESUMO

BACKGROUND: The application of kinematic data acquired during biomechanical testing to specimen-specific, three-dimensional models of the spine has emerged as a useful tool in spine biomechanics research. However, the development of these models is subject to segmentation error because of complex morphology and pathologic changes of the spine. This error has not been previously characterized. METHODS: Eight cadaveric lumbar spines were prepared and underwent computed tomography (CT) scanning. After disarticulation and soft-tissue removal, 5 individual vertebrae from these specimens were scanned a second time. The CT images of the full lumbar specimens were segmented twice each by 2 operators, and the images of the individual vertebrae with soft tissue removed were segmented as well. The solid models derived from these differing segmentation sessions were registered, and the distribution of distances between nearest neighboring points was calculated to evaluate the accuracy and precision of the segmentation technique. RESULTS: Manual segmentation yielded root-mean-square errors below 0.39 mm for accuracy, 0.33 mm for intrauser precision, and 0.35 mm for interuser precision. Furthermore, the 95th percentile of all distances was below 0.75 mm for all analyses of accuracy and precision. CONCLUSIONS: These findings indicate that such models are highly accurate and that a high level of intrauser and interuser precision can be achieved. The magnitude of the error presented here should inform the design and interpretation of future studies using manual segmentation techniques to derive models of the lumbar spine.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...