Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 302
Filtrar
1.
J Thorac Cardiovasc Surg ; 167(1): 52-62.e5, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-35260280

RESUMO

OBJECTIVES: Thoracic endovascular aortic repair is the method of choice in patients with complicated type B acute aortic dissection. However, thoracic endovascular aortic repair carries a risk of periprocedural neurological events including stroke and spinal cord ischemia. We aimed to look at procedure-related neurological complications within a large cohort of patients with type B acute aortic dissection treated by thoracic endovascular aortic repair. METHODS: Between 1996 and 2021, the International Registry of Acute Aortic Dissection collected data on 3783 patients with type B acute aortic dissection. For this analysis, 648 patients with type B acute aortic dissection treated by thoracic endovascular aortic repair were included (69.4% male, mean age 62.7 ± 13.4 years). Patients were excluded who presented with a preexisting neurologic deficit or received adjunctive procedures. Demographics, clinical symptoms, and outcomes were analyzed. The primary end point was the periprocedural incidence of neurological events (defined as stroke, spinal cord ischemia, transient neurological deficit, or coma). Predictors for perioperative neurological events and follow-up outcomes were considered as secondary end points. RESULTS: Periprocedure neurological events were noted in 72 patients (11.1%) and included strokes (n = 29, 4.6%), spinal cord ischemias (n = 21, 3.3%), transient neurological deficits (n = 16, 2.6%), or coma (n = 6, 1.0%). The group with neurological events had a significantly higher in-hospital mortality (20.8% vs 4.3%, P < .001). Patients with neurological events were more likely to be female (40.3% vs 29.3%, P = .077), and aortic rupture was more often cited as an indication for thoracic endovascular aortic repair (38.8% vs 16.5%, P < .001). In patients with neurological events, more stent grafts were used (2 vs 1 stent graft, P = .002). Multivariable logistic regression analysis showed that aortic rupture (odds ratio, 3.12, 95% confidence interval, 1.44-6.78, P = .004) and female sex (odds ratio, 1.984, 95% confidence interval, 1.031-3.817, P = .040) were significantly associated with perioperative neurological events. CONCLUSIONS: In this highly selected group from dedicated aortic centers, more than 1 in 10 patients with type B acute aortic dissection treated by thoracic endovascular aortic repair had neurological events, in particular women. Further research is needed to identify the causes and presentation of these events after thoracic endovascular aortic repair, especially among women.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Isquemia do Cordão Espinal , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Ruptura Aórtica/etiologia , Coma/etiologia , Coma/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Fatores de Risco , Isquemia do Cordão Espinal/epidemiologia , Isquemia do Cordão Espinal/etiologia , Acidente Vascular Cerebral/etiologia , Estudos Retrospectivos , Stents
2.
Struct Heart ; 7(2): 100119, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37275583

RESUMO

The bicuspid aortic valve (BAV) is the most common congenital heart defect with an estimated prevalence of between 0.5% and 2% in the United States, representing up to 6.5 million individuals. Most individuals with BAV will develop valvular and/or aortic complications related to their BAV. How these various complications relate to one another and why they arise remain elusive. Yet, astute observations have yielded relevant classification systems that leverage valvular morphology, aortic shape, and genetic alteration patterns. Emerging evidence supports the existence of BAV phenotypes that may have different patterns of disease presentation, rates of progression, and risk of secondary complications. We review the natural history of BAV in light of known classification systems to illustrate a framework through which future hemodynamic, cell biologic, and other studies can better correlate with clinical endpoints. Consistent utilization of valvular, aortic, and genetic classification systems in the management and study of BAV may facilitate insight into the patterns of the disease, with prognostic and therapeutic significance for individuals who experience this common structural heart disease.

3.
J Thorac Cardiovasc Surg ; 165(5): 1759-1770.e3, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-34887095

RESUMO

OBJECTIVE: This study sought to identify the optimal temperature for moderate hypothermic circulatory arrest in patients undergoing elective hemiarch replacement with antegrade brain perfusion. METHODS: The Society of Thoracic Surgeons adult cardiac surgery database was queried for elective hemiarch replacements using antegrade brain perfusion for aneurysmal disease (2014-2019). Generalized estimating equations and restricted cubic splines were used to determine the risk-adjusted relationships between temperature as a continuous variable and outcomes. RESULTS: Elective hemiarch replacement with antegrade brain perfusion occurred in 3898 patients at 374 centers with a median nadir temperature of 24.9°C (first quartile, third quartile = 22.0°C, 27.5°C) and median circulatory arrest time of 19 minutes (first quartile, third quartile = 14.0 minutes, 27.0 minutes). After adjustment for comorbidities, circulatory arrest time, and individual surgeon, patients cooled between 25 and 28°C had an early survival advantage compared with 24°C, whereas those cooled between 21 and 23°C had higher risks of mortality compared with 24°C. A nadir temperature of 27°C was associated with the lowest risk-adjusted odds of mortality (odds ratio, 0.62; 95% confidence interval, 0.42-0.91). A nadir temperature of 21°C had the highest risk of mortality (odds ratio, 1.4; 95% confidence interval, 1.13-1.73). Risk of experiencing a major morbidity was elevated in patients cooled between 21 and 23°C, with the highest risk occurring in patients cooled to 21°C (odds ratio, 1.12; 95% confidence interval, 1.01-1.24). CONCLUSIONS: For patients with aneurysmal disease undergoing elective hemiarch with antegrade brain perfusion, circulatory arrest with a nadir temperature of 27°C confers the greatest early survival benefit and smallest risk of postoperative morbidity.


Assuntos
Aneurisma da Aorta Torácica , Parada Cardíaca , Adulto , Humanos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Temperatura , Resultado do Tratamento , Estudos Retrospectivos , Perfusão/efeitos adversos , Encéfalo
4.
J Thorac Cardiovasc Surg ; 165(2): 544-551.e3, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-33838909

RESUMO

OBJECTIVE: To report long-term outcomes after deep hypothermic circulatory arrest (DHCA) with or without perioperative blood or blood products. METHODS: All patients who underwent proximal aortic surgery with DHCA from 2011 to 2018 were propensity matched according to baseline characteristics. Primary outcomes included short- and long-term mortality. Stratified Cox regression analysis was performed for significant associations with survival. RESULTS: A total of 824 patients underwent aortic replacement requiring circulatory arrest. After matching, there were 224 patients in each arm (transfusion and no transfusion). All baseline characteristics were well matched, with a standardized mean difference (SMD) <0.1. Preoperative hematocrit (41.0 vs 40.6; SMD = 0.05) and ejection fraction (57.5% vs 57.0%; SMD = 0.08) were similar between the no transfusion and blood product transfusion cohorts. Rate of aortic dissection (42.9% vs 45.1%; SMD = 0.05), hemiarch replacement (70.1% vs 70.1%; SMD = 0.00), and total arch replacement (21.9% vs 23.2%; SMD = 0.03) were not statistically different. Cardiopulmonary bypass and cross-clamp time were higher in the blood product transfusion cohort (P < .001). Operative mortality (9.4% vs 2.7%; P = .003), stroke (7.6% vs 1.3%; P = .001), reoperation rate, pneumonia, prolonged ventilation, and dialysis requirements were significantly higher in the transfusion cohort (P < .001). In stratified Cox regression, transfusion was an independent predictor of mortality (hazard ratio, 2.62 [confidence interval, 1.47-4.67]; P = .001). One- and 5-year survival were significantly reduced for the transfusion cohort (P < .001). CONCLUSIONS: In patients who underwent aortic surgery with DHCA, perioperative transfusions were associated with poor outcomes despite matching for preoperative baseline characteristics.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Humanos , Aorta Torácica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Diálise Renal , Parada Circulatória Induzida por Hipotermia Profunda/efeitos adversos , Aneurisma da Aorta Torácica/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia
5.
J Thorac Cardiovasc Surg ; 165(6): 1971-1981.e2, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-34384591

RESUMO

OBJECTIVE: To evaluate the ability of intraoperative neurophysiologic monitoring (IONM) during aortic arch reconstruction with hypothermic circulatory arrest (HCA) to predict early (<48 hours) adverse neurologic events (ANE; stroke or transient ischemic attack) and operative mortality. METHODS: This was an observational study of aortic arch surgeries requiring HCA from 2010 to 2018. Patients were monitored with electroencephalogram (EEG) and somatosensory evoked potentials (SSEP). Baseline characteristics and postoperative outcomes were compared according to presence or absence of IONM changes, which were defined as any acute variation in SSEP or EEG, compared with baseline. Multivariable logistic regression analysis was used to assess the association of IONM changes with operative mortality and early ANE. RESULTS: A total of 563 patients underwent aortic arch reconstruction with HCA and IONM. Of these, 119 (21.1%) patients had an IONM change, whereas 444 (78.9%) did not. Patients with IONM changes had increased operative mortality (22.7% vs 4.3%) and increased early ANE (10.9% vs 2.9%). In multivariable analysis, SSEP changes were correlated with early ANE (odds ratio [OR], 4.68; 95% confidence interval [CI], 1.51-14.56; P = .008), whereas EEG changes were not (P = .532). Permanent SSEP changes were correlated with early ANE (OR, 4.56; 95% CI, 1.51-13.77; P = .007), whereas temperature-related SSEP changes were not (P = .997). Finally, any IONM change (either SSEP or EEG) was correlated with operative mortality (OR, 5.82; 95% CI, 2.72-12.49; P < .001). CONCLUSIONS: Abnormal IONM events during aortic arch reconstruction with HCA portend worse neurologic outcomes and operative mortality and have a negative predictive value of 97.1%. SSEP might be more sensitive than EEG for predicting early ANE, especially when SSEP changes are permanent.


Assuntos
Monitorização Neurofisiológica Intraoperatória , Acidente Vascular Cerebral , Humanos , Aorta Torácica/cirurgia , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Valor Preditivo dos Testes , Perfusão/efeitos adversos , Circulação Cerebrovascular
6.
J Clin Neurophysiol ; 40(2): 180-186, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34510090

RESUMO

INTRODUCTION: This study aimed to determine the ability of multimodality intraoperative neurophysiologic monitoring, including somatosensory evoked potentials (SSEP) and EEG, to predict perioperative clinical stroke and stroke-related mortality after open-heart surgery in high-risk patients. METHODS: The records of all consecutive patients who underwent coronary artery bypass grafting, and cardiac valve repair/replacement with high risk for stroke who underwent both SSEP and EEG recording at the University of Pittsburgh Medical Center between 2009 and 2015 were reviewed. Sensitivity and specificity of these modalities to predict in-hospital clinical strokes and stroke-related mortality were calculated. RESULTS: A total of 531 patients underwent open cardiac procedures monitored using SSEP and EEG. One hundred thirty-one patients (24.67%) experienced significant changes in either modality. Fourteen patients (2.64%) suffered clinical strokes within 24 hours after surgery, and eight patients (1.50%) died during their hospitalization. The incidence of in-hospital clinical stroke and stroke-related mortality among patients who experienced a significant change in monitoring compared with those with no significant change was 11.45% versus 1.75%. The sensitivity and specificity of significant changes in either SSEP or EEG to predict in-hospital major stroke and stroke-related mortality were 0.93 and 0.77, respectively. CONCLUSIONS: Intraoperative neurophysiologic monitoring with SSEP and EEG has high sensitivity and specificity in predicting perioperative stroke and stroke-related mortality after open cardiac procedures. These results support the benefits of multimodality neuromonitoring during cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Monitorização Neurofisiológica Intraoperatória , Acidente Vascular Cerebral , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Potenciais Somatossensoriais Evocados/fisiologia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Sensibilidade e Especificidade , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos Retrospectivos
7.
Ann Thorac Surg ; 115(1): 257-264, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35609650

RESUMO

BACKGROUND: The Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) estimates mortality risk only for certain common procedures (eg, coronary artery bypass or valve surgery) and is cumbersome, requiring greater than 60 inputs. We hypothesized that deep learning can estimate postoperative mortality risk based on a preoperative chest radiograph for cardiac surgeries in which STS-PROM scores were available (STS index procedures) or unavailable (non-STS index procedures). METHODS: We developed a deep learning model (CXR-CTSurgery) to predict postoperative mortality based on preoperative chest radiographs in 9283 patients at Massachusetts General Hospital (MGH) having cardiac surgery before April 8, 2014. CXR-CTSurgery was tested on 3615 different MGH patients and externally tested on 2840 patients from Brigham and Women's Hospital (BWH) having surgery after April 8, 2014. Discrimination for mortality was compared with the STS-PROM using the C-statistic. Calibration was assessed using the observed-to-expected ratio (O/E ratio). RESULTS: For STS index procedures, CXR-CTSurgery had a C-statistic similar to STS-PROM at MGH (CXR-CTSurgery: 0.83 vs STS-PROM: 0.88; P = .20) and BWH (0.74 vs 0.80; P = .14) testing cohorts. The CXR-CTSurgery C-statistic for non-STS index procedures was similar to STS index procedures in the MGH (0.87 vs 0.83) and BWH (0.73 vs 0.74) testing cohorts. For STS index procedures, CXR-CTSurgery had better calibration than the STS-PROM in the MGH (O/E ratio: 0.74 vs 0.52) and BWH (O/E ratio: 0.91 vs 0.73) testing cohorts. CONCLUSIONS: CXR-CTSurgery predicts postoperative mortality based on a preoperative CXR with similar discrimination and better calibration than the STS-PROM. This may be useful when the STS-PROM cannot be calculated or for non-STS index procedures.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Aprendizado Profundo , Humanos , Feminino , Medição de Risco/métodos , Fatores de Risco , Ponte de Artéria Coronária
8.
Artigo em Inglês | MEDLINE | ID: mdl-36253292

RESUMO

OBJECTIVE: In this prospective US investigational device exemption trial, we assessed the safety and 1-year clinical outcomes of the Thoraflex Hybrid device (Terumo Aortic) for the frozen elephant trunk technique to repair the ascending aorta, aortic arch, and descending thoracic aorta. METHODS: For the trial, which involved 12 US sites, 65 patients without rupture were recruited into the primary study group, and 9 patients were recruited into the rupture group. All patients underwent open surgical repair of the ascending aorta, aortic arch, and descending thoracic aorta in cases of aneurysm and/or dissection. The primary end point was freedom from major adverse events (MAE), defined as permanent stroke, permanent paraplegia/paraparesis, unanticipated aortic-related reoperation (excluding reoperation for bleeding), or all-cause mortality. RESULTS: In the primary study group, 2 patients were lost to follow-up at 1 year. Freedom from MAE at 1 year was 81% (51/63). Seven patients (11%) died (including 2 before 30 days or discharge), 3 patients (5%) suffered permanent stroke, and 3 (5%) developed permanent paraplegia/paraparesis. Twenty-six patients (41%) underwent planned extension procedures, including 22 endovascular procedures within a median of 122 (interquartile range, 64-156) days. In the aortic rupture group, 2 patients were lost to follow-up at 1 year. Freedom from MAE at 1 year was 71% (5/7). One patient (14%) died, 2 patients (29%) had permanent stroke, and none had permanent paraplegia/paraparesis. No extension procedures were performed in the rupture group. CONCLUSIONS: One-year results with the Thoraflex Hybrid device are acceptable. Long-term data are necessary to assess the durability of these repairs.

9.
Artigo em Inglês | MEDLINE | ID: mdl-36207164

RESUMO

OBJECTIVE: We created a finite element model to predict the probability of dissection based on imaging-derived aortic stiffness and investigated the link between stiffness and wall tensile stress using our model. METHODS: Transthoracic echocardiogram measurements were used to calculate aortic diameter change over the cardiac cycle. Aortic stiffness index was subsequently calculated based on diameter change and blood pressure. A series of logistic models were developed to predict the binary outcome of aortic dissection using 1 or more series of predictor parameters such as aortic stiffness index or patient characteristics. Finite element analysis was performed on a subset of diameter-matched patients exhibiting patient-specific material properties. RESULTS: Transthoracic echocardiogram scans of patients with type A aortic dissection (n = 22) exhibited elevated baseline aortic stiffness index when compared with aneurysmal patients' scans with tricuspid aortic valve (n = 83, P < .001) and bicuspid aortic valve (n = 80, P < .001). Aortic stiffness index proved an excellent discriminator for a future dissection event (area under the curve, 0.9337, odds ratio, 2.896). From the parametric finite element study, we found a correlation between peak longitudinal wall tensile stress and stiffness index (ρ = .6268, P < .001, n = 28 pooled). CONCLUSIONS: Noninvasive transthoracic echocardiogram-derived aortic stiffness measurements may serve as an impactful metric toward predicting aortic dissection or quantifying dissection risk. A correlation between longitudinal stress and stiffness establishes an evidence-based link between a noninvasive stiffness parameter and stress state of the aorta with clinically apparent dissection events.

10.
JAMA Cardiol ; 7(10): 1009-1015, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36001309

RESUMO

Importance: Early data revealed a mortality rate of 1% to 2% per hour for type A acute aortic dissection (TAAAD) during the initial 48 hours. Despite advances in diagnostic testing and treatment, this mortality rate continues to be cited because of a lack of contemporary data characterizing early mortality and the effect of timely surgery. Objective: To examine early mortality rates for patients with TAAAD in the contemporary era. Design, Setting, and Participants: This cohort study examined data for patients with TAAAD in the International Registry of Acute Aortic Dissection between 1996 and 2018. Patients were grouped according to the mode of their intended treatment, surgical or medical. Exposure: Surgical treatment. Main Outcomes and Measures: Mortality was assessed in the initial 48 hours after hospital arrival using Kaplan-Meier curves. In-hospital complications were also evaluated. Results: A total of 5611 patients with TAAAD were identified based on intended treatment: 5131 (91.4%) in the surgical group (3442 [67.1%] male; mean [SD] age, 60.4 [14.1] years) and 480 (8.6%) in the medical group (480 [52.5%] male; mean [SD] age, 70.9 [14.7] years). Reasons for medical management included advanced age (n = 141), comorbidities (n = 281), and patient preference (n = 81). Over the first 48 hours, the mortality for all patients in the study was 5.8%. Among patients who were medically managed, mortality was 0.5% per hour (23.7% at 48 hours). For those whose intended treatment was surgical, 48-hour mortality was 4.4%. In the surgical group, 51 patients (1%) died before the operation. Conclusions and Relevance: In this study, the overall mortality rate for TAAAD was 5.8% at 48 hours. For patients in the medical group, TAAAD had a mortality rate of 0.5% per hour (23.7% at 48 hours). However, among those in the surgical group, 48-hour mortality decreased to 4.4%.


Assuntos
Dissecção Aórtica , Doença Aguda , Idoso , Dissecção Aórtica/epidemiologia , Estudos de Coortes , Comorbidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros
11.
JAMA Cardiol ; 7(10): 1000-1008, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36001335

RESUMO

Importance: In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective: To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants: SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention: Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures: The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results: A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm2 vs 1.8 [0.6] cm2; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance: Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Masculino , Estudos Prospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
12.
Ann Biomed Eng ; 50(12): 1771-1786, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35943618

RESUMO

The aim of this study was to determine whether specific three-dimensional aortic shape features, extracted via statistical shape analysis (SSA), correlate with the development of thoracic ascending aortic dissection (TAAD) risk and associated aortic hemodynamics. Thirty-one patients followed prospectively with ascending thoracic aortic aneurysm (ATAA), who either did (12 patients) or did not (19 patients) develop TAAD, were included in the study, with aortic arch geometries extracted from computed tomographic angiography (CTA) imaging. Arch geometries were analyzed with SSA, and unsupervised and supervised (linked to dissection outcome) shape features were extracted with principal component analysis (PCA) and partial least squares discriminant analysis (PLS-DA), respectively. We determined PLS-DA to be effective at separating dissection and no-dissection patients ([Formula: see text]), with decreased tortuosity and more equal ascending and descending aortic diameters associated with higher dissection risk. In contrast, neither PCA nor traditional morphometric parameters (maximum diameter, tortuosity, or arch volume) were effective at separating dissection and no-dissection patients. The arch shapes associated with higher dissection probability were supported with hemodynamic insight. Computational fluid dynamics (CFD) simulations revealed a correlation between the PLS-DA shape features and wall shear stress (WSS), with higher maximum WSS in the ascending aorta associated with increased risk of dissection occurrence. Our work highlights the potential importance of incorporating higher dimensional geometric assessment of aortic arch anatomy in TAAD risk assessment, and in considering the interdependent influences of arch shape and hemodynamics as mechanistic contributors to TAAD occurrence.


Assuntos
Dissecção Aórtica , Humanos , Dissecção Aórtica/diagnóstico por imagem , Aorta , Aorta Torácica/diagnóstico por imagem , Hemodinâmica
13.
J Vasc Surg ; 76(5): 1189-1197.e3, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35809819

RESUMO

OBJECTIVE: To provide the 5-year outcomes of the use of a composite device (proximal covered stent graft + distal bare stent) for endovascular repair of patients with acute, type B aortic dissection complicated by aortic rupture and/or malperfusion. METHODS: Study of Thoracic Aortic Type B Dissection Using Endoluminal Repair (STABLE) II was a prospective, multicenter study of the Zenith Dissection Endovascular System (William Cook Europe). Patients were enrolled between August 2012 and January 2015 at sites in the United States and Japan. Five-year follow-up was completed by January 2020. RESULTS: In total, 73 patients (mean age: 60.7 ± 10.9 years; 65.8% male) with acute type B dissection complicated by malperfusion (72.6%), rupture (21.9%), or both (5.5%) were enrolled. Patients were treated with either a composite device (79.5%) or the proximal stent graft alone (no distal bare stent, 20.5%). Dissections were more extensive in patients who received the composite device (408.9 ± 121.3 mm) than in patients who did not receive a bare stent (315.9 ± 100.1 mm). The mean follow-up was 1209.4 ± 754.6 days. Freedom from all-cause mortality was 80.3% ± 4.7% at 1 year and 68.9% ± 7.3% at 5 years. Freedom from dissection-related mortality remained at 97.1% ± 2.1% from 1-year through 5-year follow-up. Within the stent-graft region, the rate of either complete thrombosis or elimination of the false lumen increased over time (82.1% of all patients at 5 years vs 55.7% at first postprocedure computed tomography), with a higher rate at 5 years in patients who received the composite device (90.5%) compared with patients without the bare stent (57.1%). Throughout the follow-up, overall true lumen diameter increased within the stent-graft region, and overall false lumen diameter decreased. At 5 years, 20.7% of patients experienced a decrease in maximum transaortic diameter within the stent-graft region, 17.2% experienced an increase, and 62.1% experienced no change. Distal to the treated segment (but within the dissected aorta), 23.1% of patients experience no change in transaortic diameter at 5 years; a bare stent was deployed in all these patients at the procedure. Five-year freedom from all secondary intervention was 70.7% ± 7.2%. CONCLUSIONS: These 5-year outcomes indicate a low rate of dissection-related mortality for the Zenith Dissection Endovascular System in the treatment of patients with acute, complicated type B aortic dissection. Further, these data suggest a positive influence of composite device use on false lumen thrombosis. Continuous monitoring for distal aortic growth is necessary in all patients.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Trombose , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Prótese Vascular , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Dissecção Aórtica/complicações , Stents , Trombose/etiologia , Resultado do Tratamento , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações
14.
J Surg Res ; 278: 317-324, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35689983

RESUMO

INTRODUCTION: Although randomized trial data exist for 2-y outcomes comparing isolated coronary artery bypass grafting (CABG) versus CABG with concomitant mitral valve repair (CABG + MVr) for the treatment of moderate ischemic mitral regurgitation (IMR), longer term outcomes are unclear. This study evaluated the longitudinal outcomes of isolated CABG for moderate IMR. METHODS: Patients with moderate IMR undergoing isolated CABG from January 2010 to February 2018 at a single institution were included. Outcomes included longitudinal freedom from heart failure readmission, survival, rates of persistent mitral regurgitation (MR), and freedom from mitral valve reinterventions. A subanalysis was conducted comparing CABG versus CABG + MVr. Multivariable Cox regression was used for risk adjustment. RESULTS: A total of 528 patients with moderate IMR underwent isolated CABG. Postoperatively, 26% of patients had at least moderate MR at 1-mo follow-up, although at 5 y progression to severe MR was rare (2.2%) as were mitral valve reinterventions (0.2%). Survival at 30 d (95.8%), 1 y (89.6%), and 5 y (76.6%) was acceptable. Furthermore, the freedom from readmission for heart failure was also acceptable at 30 d (92.6%), 1 y (79.9%), and 5 y (65.0%) postoperatively. In a subanalysis comparing CABG versus CABG + MVr, unadjusted and risk-adjusted survival, freedom from heart failure readmissions, mitral valve reinterventions, and degrees of MR were comparable between the groups at all intervals (all P > 0.05). CONCLUSIONS: The majority of patients with moderate IMR can undergo isolated CABG with acceptable rates of heart failure readmissions, survival, progression to severe MR, and the need for subsequent mitral interventions. These data support the use of isolated CABG in patients with moderate IMR.


Assuntos
Doença da Artéria Coronariana , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Isquemia Miocárdica , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Insuficiência Cardíaca/complicações , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Isquemia Miocárdica/complicações , Isquemia Miocárdica/cirurgia , Resultado do Tratamento
15.
J Biomed Mater Res A ; 110(12): 1912-1920, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35770946

RESUMO

Pericytes are essential components of small blood vessels and are found in human aortic vasa vasorum. Prior work uncovered lower vasa vasorum density and decreased levels of pro-angiogenic growth factors in adventitial specimens of human ascending thoracic aortic aneurysm. We hypothesized that adventitial extracellular matrix (ECM) from normal aorta promotes pericyte function by increasing pericyte contractile function through mechanisms deficient in ECM derived from aneurysmal aortic adventitia. ECM biomaterials were prepared as lyophilized particulates from decellularized adventitial specimens of human and porcine aorta. Immortalized human aortic adventitia-derived pericytes were cultured within Type I collagen gels in the presence or absence of human or porcine adventitial ECMs. Cell contractility index was quantified by measuring the gel area immediately following gelation and after 48 h of culture. Normal human and porcine adventitial ECM increased contractility of pericytes when compared with pericytes cultured in absence of adventitial ECM. In contrast, aneurysm-derived human adventitial ECM failed to promote pericyte contractility. Pharmacological inhibition of TGFßR1 and antibody blockade of α2 ß1 integrin independently decreased porcine adventitial ECM-induced pericyte contractility. By increasing pericyte contractility, adventitial ECM may improve microvascular function and thus represents a candidate biomaterial for less invasive and preventative treatment of human ascending aortic disease.


Assuntos
Túnica Adventícia , Vasa Vasorum , Túnica Adventícia/metabolismo , Animais , Materiais Biocompatíveis/metabolismo , Colágeno Tipo I/metabolismo , Matriz Extracelular , Humanos , Hidrogéis/metabolismo , Hidrogéis/farmacologia , Integrinas/metabolismo , Pericitos , Suínos , Fator de Crescimento Transformador beta/metabolismo , Vasa Vasorum/metabolismo
16.
Eur J Cardiothorac Surg ; 62(5)2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-35460403

RESUMO

OBJECTIVES: We hypothesized that expression and activity of nitric oxide synthase-3 enzyme (Nos3) in bicuspid aortic valve (BAV) aortopathy are related to tissue layer and Nos3 genotype. METHODS: Gene expression of Nos3 and platelet and endothelial cell adhesion molecule-1 (Pecam1) and NOS activity were measured in intima-containing media and adventitial specimens of ascending aortic tissue. The presence of 2 Nos3 single-nucleotide polymorphisms (SNPs; -786T/C and 894G/T) was determined for non-aneurysmal (NA) and aneurysmal patients with BAV (n = 40, 89, respectively); patients with tricuspid aortic valve (TAV) and aneurysm (n = 151); and NA patients with TAV (n = 100). RESULTS: Elevated Nos3 relative to Pecam1 and reduced Pecam1 relative to a housekeeping gene were observed within intima-containing aortic specimens from BAV patients when compared with TAV patients. Lower Nos3 in the adventitia of aneurysmal specimens was noted when compared with specimens of NA aorta, independent of valve morphology. NOS activity was similar among cohorts in media/intima and decreased in the diseased adventitia, relative to control patients. Aneurysmal BAV patients exhibited an under-representation of the wild-type genotype for -786 SNP. No differences in genotype distribution were noted for 894 SNP. Primary intimal endothelial cells from patients with at least 1 C allele at -786 SNP exhibited lower Nos3 when compared with wild-type cells. CONCLUSIONS: These findings of differential Nos3 in media/intima versus adventitia depending on valve morphology or aneurysm reveal new information regarding aneurysmal pathophysiology and support our ongoing assertion that there are distinct mechanisms giving rise to ascending aortopathy in BAV and TAV patients.


Assuntos
Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Humanos , Doenças das Valvas Cardíacas/genética , Doenças das Valvas Cardíacas/metabolismo , Células Endoteliais/metabolismo , Valva Aórtica/metabolismo , Genótipo , Óxido Nítrico Sintase Tipo III/genética , Óxido Nítrico Sintase Tipo III/metabolismo
17.
J Am Coll Cardiol ; 79(9): 882-896, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-35241222

RESUMO

BACKGROUND: The Evolut Low Risk Trial (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients) showed that transcatheter aortic valve replacement (TAVR) with a supra-annular, self-expanding valve was noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke at 2 years. This finding was based on a Bayesian analysis performed after 850 patients had reached 1 year of follow-up. OBJECTIVES: The goal of this study was to report the full 2-year clinical and echocardiographic outcomes for patients enrolled in the Evolut Low Risk Trial. METHODS: A total of 1,414 low-surgical risk patients with severe aortic stenosis were randomized to receive TAVR or surgical AVR. An independent clinical events committee adjudicated adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 730 TAVR and 684 surgical patients from March 2016 to May 2019. The Kaplan-Meier rates for the complete 2-year primary endpoint of death or disabling stroke were 4.3% in the TAVR group and 6.3% in the surgery group (P = 0.084). These rates were comparable to the interim Bayesian rates of 5.3% with TAVR and 6.7% with surgery (difference: -1.4%; 95% Bayesian credible interval: -4.9% to 2.1%). All-cause mortality rates were 3.5% vs 4.4% (P = 0.366), and disabling stroke rates were 1.5% vs 2.7% (P = 0.119), respectively. Between years 1 and 2, there was no convergence of the primary outcome curves. CONCLUSIONS: The complete 2-year follow-up from the Evolut Low Risk Trial found that TAVR is noninferior to surgery for the primary endpoint of all-cause mortality or disabling stroke, with event rates that were slightly better than those predicted by using the Bayesian analysis. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients [Evolut Low Risk Trial]; NCT02701283).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Teorema de Bayes , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Desenho de Prótese , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
Circ Cardiovasc Imaging ; 15(3): e000075, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35172599

RESUMO

All patients surviving an acute aortic dissection require continued lifelong surveillance of their diseased aorta. Late complications, driven predominantly by chronic false lumen degeneration and aneurysm formation, often require surgical, endovascular, or hybrid interventions to treat or prevent aortic rupture. Imaging plays a central role in the medical decision-making of patients with chronic aortic dissection. Accurate aortic diameter measurements and rigorous, systematic documentation of diameter changes over time with different imaging equipment and modalities pose a range of practical challenges in these complex patients. Currently, no guidelines or recommendations for imaging surveillance in patients with chronic aortic dissection exist. In this document, we present state-of-the-art imaging and measurement techniques for patients with chronic aortic dissection and clarify the need for standardized measurements and reporting for lifelong surveillance. We also examine the emerging role of imaging and computer simulations to predict aortic false lumen degeneration, remodeling, and biomechanical failure from morphological and hemodynamic features. These insights may improve risk stratification, individualize contemporary treatment options, and potentially aid in the conception of novel treatment strategies in the future.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , American Heart Association , Dissecção Aórtica/cirurgia , Dissecção Aórtica/terapia , Aneurisma da Aorta Torácica/cirurgia , Aortografia/métodos , Prótese Vascular , Procedimentos Endovasculares/métodos , Humanos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
19.
J Surg Res ; 272: 166-174, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34979472

RESUMO

BACKGROUND: This study evaluates the clinical and renal-related outcomes in patients with acute renal failure (ARF) following cardiac surgery. METHODS: Index adult cardiac operations at a single institution from 2010-2018 were reviewed. Patients requiring dialysis pre-operatively were excluded. ARF was stratified as either creatinine rise (≥3-times baseline or ≥4.0 mg/dL) or post-operative dialysis. Outcomes included mortality, rates of progression to dialysis, and renal recovery. Multivariable Cox regression was used for risk-adjustment. RESULTS: A total of 10,037 patients, including 6,275 (62.5%) isolated coronary artery bypass grafting (CABG), 2,243 (22.3%) isolated valve, and 1,519 (15.1%) CABG plus valve cases, were included. Post-operative ARF occurred in 346 (3.5%) patients, with 230 (66.5%) requiring dialysis. Survival was significantly reduced in patients with ARF at 30-days (97.9 versus 70.8%, P <0.001), 1-year (94.9 versus 48.0%, P <0.001), and 5-years (86.2 versus 38.2%, P <0.001) with more profound reductions in those requiring dialysis, findings which persisted after risk-adjustment. Progression to subsequent dialysis in the creatinine rise group was rare (n = 1). The median time to dialysis initiation in the dialysis group was 5 days (IQR 2-12 days) with a median time of dialysis dependence of 72 days (IQR 38-1229 days). Of those patients requiring postoperative dialysis, 30.9% demonstrated renal recovery. CONCLUSIONS: Post-operative ARF and in particular the need for dialysis are associated with substantial reductions in survival that persist during longitudinal follow-up. This occurs despite the finding that patients experiencing creatinine rise only rarely progress to dialysis, and that nearly one-third of patients requiring post-operative dialysis recover renal function.


Assuntos
Injúria Renal Aguda , Procedimentos Cirúrgicos Cardíacos , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/terapia , Adulto , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Creatinina , Feminino , Humanos , Rim/fisiologia , Masculino , Diálise Renal/efeitos adversos , Fatores de Risco
20.
Eur J Cardiothorac Surg ; 61(4): 838-846, 2022 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-34977934

RESUMO

OBJECTIVES: We sought to examine management and outcomes of (Stanford) type A aortic dissection (TAAAD) in patients aged >70 years. METHODS: All patients with TAAAD enrolled in the International Registry of Acute Aortic Dissection database (1996-2018) were studied (n = 5553). Patients were stratified by age and therapeutic strategy. Outcomes for octogenarians were compared with those for septuagenarians. Variables associated with in-hospital mortality were identified by multivariable logistic regression. RESULTS: In-hospital mortality for all patients (all ages) was 19.7% (1167 deaths), 16.1% after surgical intervention vs 52.1% for medical management (P < 0.001). Of the study population, 1281 patients (21.6%) were aged 71-80 years and 475 (8.0%) were >80 years. Fewer octogenarians underwent surgery versus septuagenarians (68.1% vs 85.9%, P < 0.001). Overall mortality was higher for octogenarians versus septuagenarians (32.0% vs 25.6%, P = 0.008); however, surgical mortality was similar (25.1% vs 21.7%, P = 0.205). Postoperative complications were comparable between surgically managed cohorts, although reoperation for bleeding was more common in septuagenarians (8.1% vs 3.2%, P = 0.033). Kaplan-Meier 5-year survival was significantly superior after surgical repair in all age groups, including septuagenarians (57.0% vs 13.7%, P < 0.001) and octogenarians (35.5% vs 22.6%, P < 0.001). CONCLUSIONS: When compared with septuagenarians, a smaller percentage of octogenarians undergo surgical repair for TAAAD, even though postoperative outcomes are similar. Age alone should not preclude consideration for surgery in appropriately selected patients with TAAAD.


Assuntos
Dissecção Aórtica , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Mortalidade Hospitalar , Humanos , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...