Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pneumologie ; 78(6): 417-419, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38096911

RESUMO

A 24-year-old male patient, without further symptoms or comorbidities presented to the emergency room with acute dyspnea after heavy lifting two days before. On auscultation an attenuated vesicular breath was noticed on the right lung. In the initial chest radiograph a right-sided primary spontaneous pneumothorax with minor mediastinal shift was diagnosed. After insertion of a 12-French chest tube the patient's clinical condition deteriorated. The following chest radiograph and computed tomography of the thorax showed a reexpansion pulmonary edema in the right lung. The patient was admitted to the ICU and supportive treatment was initiated. Pulmonary reexpansion edema after drainage of a pneumothorax is a very rare complication with mortality rates reaching up to 20%. The exact pathophysiology remains unknown. Typical Symptoms include dyspnea, hypotension, and tachycardia. To minimize the risk of a pulmonary reexpansion edema, not more than 1200-1800 ml of air should be drained at once and the drainage should be stopped when the patient starts coughing.


Assuntos
Pneumotórax , Edema Pulmonar , Humanos , Masculino , Pneumotórax/etiologia , Pneumotórax/terapia , Pneumotórax/diagnóstico por imagem , Pneumotórax/diagnóstico , Edema Pulmonar/etiologia , Edema Pulmonar/terapia , Edema Pulmonar/diagnóstico por imagem , Adulto Jovem , Drenagem , Tubos Torácicos , Resultado do Tratamento
2.
J Clin Monit Comput ; 35(5): 1203-1209, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-32749570

RESUMO

Pulse pressure variation (PPV) and cardiac output (CO) can guide perioperative fluid management. Capstesia (Galenic App, Vitoria-Gasteiz, Spain) is a mobile application for snapshot pulse wave analysis (PWAsnap) and estimates PPV and CO using pulse wave analysis of a snapshot of the arterial blood pressure waveform displayed on any patient monitor. We evaluated the PPV and CO measurement performance of PWAsnap in adults having major abdominal surgery. In a prospective study, we simultaneously measured PPV and CO using PWAsnap installed on a tablet computer (PPVPWAsnap, COPWAsnap) and using invasive internally calibrated pulse wave analysis (ProAQT; Pulsion Medical Systems, Feldkirchen, Germany; PPVProAQT, COProAQT). We determined the diagnostic accuracy of PPVPWAsnap in comparison to PPVProAQT according to three predefined PPV categories and by computing Cohen's kappa coefficient. We compared COProAQT and COPWAsnap using Bland-Altman analysis, the percentage error, and four quadrant plot/concordance rate analysis to determine trending ability. We analyzed 190 paired PPV and CO measurements from 38 patients. The overall diagnostic agreement between PPVPWAsnap and PPVProAQT across the three predefined PPV categories was 64.7% with a Cohen's kappa coefficient of 0.45. The mean (± standard deviation) of the differences between COPWAsnap and COProAQT was 0.6 ± 1.3 L min- 1 (95% limits of agreement 3.1 to - 1.9 L min- 1) with a percentage error of 48.7% and a concordance rate of 45.1%. In adults having major abdominal surgery, PPVPWAsnap moderately agrees with PPVProAQT. The absolute and trending agreement between COPWAsnap with COProAQT is poor. Technical improvements are needed before PWAsnap can be recommended for hemodynamic monitoring.


Assuntos
Aplicativos Móveis , Adulto , Pressão Sanguínea , Débito Cardíaco , Humanos , Estudos Prospectivos , Análise de Onda de Pulso , Reprodutibilidade dos Testes , Termodiluição
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...