Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Magn Reson Med ; 78(3): 1147-1156, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-27779790

RESUMO

PURPOSE: Diffusion-weighted imaging (DWI) and 18 F-fluorodeoxyglucose-positron emission tomography (18 F-FDG-PET) independently correlate with malignancy in breast cancer, but the relationship between their structural and metabolic metrics is not completely understood. This study spatially correlates diffusion, perfusion, and glucose avidity in breast cancer with simultaneous PET/MR imaging and compares correlations with clinical prognostics. METHODS: In this Health Insurance Portability and Accountability Act-compliant prospective study, with written informed consent and approval of the institutional review board and using simultaneously acquired FDG-PET and DWI, tissue diffusion (Dt ), and perfusion fraction (fp ) from intravoxel incoherent motion (IVIM) analysis were registered to FDG-PET within 14 locally advanced breast cancers. Lesions were analyzed using 2D histograms and correlation coefficients between Dt , fp , and standardized uptake value (SUV). Correlations were compared with prognostics from biopsy, metastatic burden from whole-body PET, and treatment history. RESULTS: SUV||Dt correlation coefficient significantly distinguished treated (0.11 ± 0.24) from nontreated (-0.33 ± 0.26) patients (P = 0.005). SUV||fp correlations were on average negative for the whole cohort (-0.17 ± 0.13). CONCLUSION: Simultaneously acquired and registered FDG-PET/DWI allowed quantifiable descriptions of breast cancer microenvironments that may provide a framework for monitoring and predicting response to treatment. Magn Reson Med 78:1147-1156, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Feminino , Fluordesoxiglucose F18 , Humanos , Pessoa de Meia-Idade , Movimento/fisiologia
2.
Abdom Radiol (NY) ; 41(5): 919-25, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27193790

RESUMO

PURPOSE: The purpose of this study was to assess the feasibility of zoomed echo-planar imaging (EPI) diffusion tensor imaging (DTI) with 2-channel parallel transmission (pTx) for MR tractography of the periprostatic neurovascular bundle (NVB) without an endorectal coil, and to compare its performance to that of conventionally acquired DTI. METHODS: 8 healthy males (28.9 ± 4.6 years) underwent pelvic phased-array coil prostate MRI on a 3T system using both zoomed-EPI DTI (z-DTI) with 2-channel pTx and conventional single-shot spin-echo EPI DTI (c-DTI) acquisitions with 6 encoding directions and b-values of 0 and 1000 s/mm(2). Fractional anisotropy (FA) maps and tractography analysis incorporating 3D visualization of the NVB were performed from each acquisition. Fiber tract counts, estimated signal-to-noise ratio (eSNR), and image quality measures of the FA maps and NVB tractography were compared. Quantitative and image quality measures were compared using Wilcoxon signed rank tests. RESULTS: 3 of 8 subjects had no tracts detected with c-DTI acquisition, while all 8 had tracts detected with z-DTI. z-DTI acquisition yielded significantly more fiber tracts (c-DTI: 77 ± 116 tracts; z-DTI: 430 ± 228 tracts; p = 0.019) and higher eSNR (c-DTI: 2.9 ± 1.2; z-DTI: 13.17 ± 9.9; p = 0.014). Relative to c-DTI acquisitions, z-DTI FA maps showed significantly reduced artifact (p = 0.008) and reduced anatomic distortion of the prostate (p = 0.010), while z-DTI tractography showed significantly better overall visual quality (p = 0.011), tract symmetry (p = 0.010), tract coherence (p = 0.011), and subjective similarity to the actual NVB (p = 0.011). CONCLUSION: Zoomed-EPI DTI acquisition for tractography of the prostate gland NVB improves quantitative and qualitative measures of image and tract fiber quality, allowing tractography of the NVB at 3T without using an endorectal coil.


Assuntos
Imagem de Tensor de Difusão , Imagem Ecoplanar , Próstata/inervação , Adulto , Algoritmos , Anisotropia , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Fibras Nervosas Mielinizadas , Próstata/irrigação sanguínea , Prostatectomia , Razão Sinal-Ruído
3.
Abdom Imaging ; 40(7): 2323-30, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25985968

RESUMO

PURPOSE: To perform image quality comparison between accelerated multiband diffusion acquisition (mb2-DWI) and conventional diffusion acquisition (c-DWI) in patients undergoing clinically indicated liver MRI. METHODS: In this prospective study 22 consecutive patients undergoing clinically indicated liver MRI on a 3-T scanner equipped to perform multiband diffusion-weighed imaging (mb-DWI) were included. DWI was performed with single-shot spin-echo echo-planar technique with fat-suppression in free breathing with matching parameters when possible using c-DWI, mb-DWI, and multiband DWI with a twofold acceleration (mb2-DWI). These diffusion sequences were compared with respect to various parameters of image quality, lesion detectability, and liver ADC measurements. RESULTS: Accelerated mb2-DWI was 40.9% faster than c-DWI (88 vs. 149 s). Various image quality parameter scores were similar or higher on mb2-DWI when compared to c-DWI. The overall image quality score (averaged over the three readers) was significantly higher for mb-2 compared to c-DWI for b = 0 s/mm(2) (3.48 ± 0.52 vs. 3.21 ± 0.54; p = 0.001) and for b = 800 s/mm(2) (3.24 ± 0.76 vs. 3.06 ± 0.86; p = 0.010). Total of 25 hepatic lesions were visible on mb2-DWI and c-DWI, with identical lesion detectability. There was no significant difference in liver ADC between mb2-DWI and c-DWI (p = 0.12). Bland-Altman plot demonstrates lower mean liver ADC with mb2-DWI compared to c-DWI (by 0.043 × 10(-3) mm(2)/s or 3.7% of the average ADC). CONCLUSION: Multiband technique can be used to increase acquisition speed nearly twofold for free-breathing DWI of the liver with similar or improved overall image quality and similar lesion detectability compared to conventional DWI.


Assuntos
Imagem de Difusão por Ressonância Magnética , Hepatopatias/patologia , Fígado/patologia , Respiração , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes
4.
Am J Nucl Med Mol Imaging ; 4(5): 459-70, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25143864

RESUMO

Integrated PET/MR with simultaneous acquisition may improve the identification of pathologic findings in patients. This pilot study evaluated metabolic activity differences between epilepsy patients and healthy controls and directly correlated FDG uptake with MR regional abnormality. Epilepsy patients (n=11) and controls (n=6) were imaged on a whole-body simultaneous PET/MR scanner. After FDG injection, simultaneous images were acquired for 60 minutes. Statistical analyses on SUV values (over 117 brain regions, including left and right, for 96 cortical and 21 subcortical regions) derived from three normalization methods, by individual subject's mean cortical, white matter or global brain, were compared between groups. The asymmetry was compared. T2, T1 and PET co-registered images were also used for lesion detection and correlation of PET and MR regional abnormality. Left and right postcentral gyri were found to be consistently hypermetabolic regions, while right temporal pole and planum polare were consistently hypometabolic regions by all three normalization methods. Using the asymmetry index (AI > 10% or SUV ratios > 1.2), more metabolic asymmetry regions were detected in patients than in controls, with 96.2% agreement. The presence of hippocampal abnormalities or cortical tubers detected via T2 FLAIR in patients correlated well with the hypometabolism detected via FDG-PET. Our results showed specific patterns of metabolic abnormality and asymmetry over 117 brain regions in epilepsy patients, as compared to controls, suggest that simultaneous PET/MR imaging provides a useful tool to help understand etiopathogenesis and localize seizure foci.

7.
Physiother Res Int ; 19(2): 117-25, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21766399

RESUMO

BACKGROUND AND PURPOSE: This case series assesses the effects of five consecutive days of low-frequency (1 Hz) repetitive transcranial magnetic stimulation (rTMS) with and without a 6-Hz primer. Although this paper studies able-bodied individuals, similar rTMS protocols are used to facilitate motor recovery in patients with hemiplegia following stroke. However, the cortical mechanisms associated with repeated daily doses of rTMS are not completely understood. CASE DESCRIPTION: Four right-handed healthy volunteers (two men, aged 20-50 years) participated in a double-blind case series of primed and unprimed rTMS. Functional magnetic resonance imaging was used to compare task-related haemodynamics during a simple motor task and resting-state cortical connectivity. Understanding the mechanisms of repeated rTMS sessions may serve as a precursor to development of rTMS paradigms involving motor cortex stimulation in patients with a range of neurologic dysfunction. OUTCOMES: Following five consecutive days of rTMS, all subjects had reduced task-related haemodynamics. Resting-state brain connectivity between motor regions was reduced only after primed rTMS. DISCUSSION: This is the first study to indicate that resting-state brain connectivity can distinguish the effect of primed and unprimed rTMS to a greater extent than task-related haemodynamics. Furthermore, priming may inhibit the connectivity between the area of the cortex underlying the rTMS site and remote brain regions. SIGNIFICANCE: These findings benefit rTMS rehabilitation studies by examining haemodynamics on repeated days of stimulation and incorporating resting-state brain connectivity analysis to further understand underlying neural mechanisms. Furthermore, this work encourages the utilization of resting connectivity in future rTMS studies.


Assuntos
Córtex Cerebral/fisiologia , Imageamento por Ressonância Magnética , Estimulação Magnética Transcraniana/métodos , Adulto , Método Duplo-Cego , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Rede Nervosa/fisiologia , Vias Neurais/fisiologia , Plasticidade Neuronal/fisiologia , Oxigênio/sangue , Adulto Jovem
8.
AJR Am J Roentgenol ; 201(5): 1115-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24147485

RESUMO

OBJECTIVE: The purpose of this study was to assess the correlation between standardized uptake value (SUV) and apparent diffusion coefficient (ADC) of neoplastic lesions in the use of a simultaneous PET/MRI hybrid system. SUBJECTS AND METHODS: Twenty-four patients with known primary malignancies underwent FDG PET/CT. They then underwent whole-body PET/MRI. Diffusion-weighted imaging was performed with free breathing and a single-shot spin-echo echo-planar imaging sequence with b values of 0, 350, and 750 s/mm(2). Regions of interest were manually drawn along the contours of neoplastic lesions larger than 1 cm, which were clearly identified on PET and diffusion-weighted images. Maximum SUV (SUVmax) on PET/MRI and PET/CT images, mean SUV (SUVmean), minimum ADC (ADCmin), and mean ADC (ADCmean) were recorded on PET/MR images for each FDG-avid neoplastic soft-tissue lesion with a maximum of three lesions per patient. Pearson correlation coefficient was used to asses the following relations: SUVmax versus ADCmin on PET/MR and PET/CT images, SUVmean versus ADCmean, and ratio of SUVmax to mean liver SUV (SUV ratio) versus ADCmin. A subanalysis of patients with progressive disease versus partial treatment response was performed with the ratio of SUVmax to ADCmin for the most metabolically active lesion. RESULTS: Sixty-nine neoplastic lesions (52 nonosseous lesions, 17 bone metastatic lesions) were evaluated. The mean SUVmax from PET/MRI was 7.0 ± 6.0; SUVmean, 5.6 ± 4.6; mean ADCmin, 1.10 ± 0.58; and mean ADCmean, 1.48 ± 0.72. A significant inverse Pearson correlation coefficient was found between PET/MRI SUVmax and ADCmin (r = -0.21, p = 0.04), between SUVmean and ADCmean (r = -0.18, p = 0.07), and between SUV ratio and ADCmin (r = -0.27, p = 0.01). A similar inverse Pearson correlation coefficient was found between the PET/CT SUVmax and ADCmin. Twenty of 24 patients had previously undergone PET/CT; five patients had a partial treatment response, and six had progressive disease according to Response Evaluation Criteria in Solid Tumors 1.1. The ratio between SUVmax and ADCmin was higher among patients with progressive disease than those with a partial treatment response. CONCLUSION: Simultaneous PET/MRI is a promising technology for the detection of neoplastic disease. There are inverse correlations between SUVmax and ADCmin and between SUV ratio and ADCmin. Correlation coefficients between SUVmax and ADCmin from PET/MRI were similar to values obtained with SUVmax from the same-day PET/CT. Given that both SUV and ADC are related to malignancy and that the correlation between the two biomarkers is relatively weak, SUV and ADC values may offer complementary information to aid in determination of prognosis and treatment response. The combined tumoral biomarker, ratio between SUVmax and ADCmin, may be useful for assessing progressive disease versus partial treatment response.


Assuntos
Imagem Multimodal , Neoplasias/diagnóstico , Imagem Corporal Total , Idoso , Imagem de Difusão por Ressonância Magnética , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
9.
AJR Am J Roentgenol ; 201(5): 1120-3, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24147486

RESUMO

OBJECTIVE: The purpose of this study was to compare the accuracy of the spatial registration of conventional PET/CT with that of hybrid PET/MRI of patients with FDG-avid metastatic lesions. SUBJECTS AND METHODS: Thirteen patients with known metastatic lesions underwent FDG PET/CT followed by PET/MRI with a hybrid whole-body system. The inclusion criterion for tumor analysis was spherical or oval FDG-avid tumor clearly identified with both CT and MRI. The spatial coordinates (x, y, z) of the visually estimated centers of the lesions were determined for PET/CT (PET and CT independently) and PET/MRI (PET, T1-weighted gradient-echo sequence with radial stack-of-stars trajectory, T2-weighted sequence), and the b0 images of an echo-planar imaging (EPI) diffusion-weighted imaging (DWI) acquisition. All MRI sequences were performed in the axial plane with free breathing. The spatial coordinates of the estimated centers of the lesions were determined for PET and CT and PET and MRI sequences. Distance between the isocenter of the lesion on PET images and on the images obtained with the anatomic modalities was measured, and misregistration (in millimeters) was calculated. The degree of misregistration was compared between PET/CT and PET/MRI with a paired Student t test. RESULTS: Nineteen lesions were evaluated. On PET/CT images, the average of the total misregistration in all planes of CT compared with PET was 4.13 ± 4.24 mm. On PET/MR images, lesion misregistration between PET and T1-weighted gradient-echo images had a shift of 2.41 ± 1.38 mm and between PET and b0 DW images was 5.97 ± 2.83 mm. Similar results were calculated for 11 lesions on T2-weighted images. The shift on T2-weighted images compared with PET images was 2.24 ± 1.12 mm. Paired Student t test calculations for PET/CT compared with PET/MRI T1-weighted gradient-echo images with a radial stack-of-stars trajectory, b0 DW images, and T2-weighted images showed significant differences (p < 0.05). Similar results were seen in the analysis of six lung lesions. CONCLUSION: PET/MRI T1-weighted gradient-echo images with a radial stack-of-stars trajectory and T2-weighted images had more accurate spatial registration than PET/CT images. This may be because that the whole-body PET/MRI system used can perform simultaneous acquisition, whereas the PET/CT system acquires data sequentially. However, the EPI-based b0 DWI datasets were significantly misregistered compared with the PET/CT datasets, especially in the thorax. Radiologists reading PET/MR images should be aware of the potential for misregistration on images obtained with EPI-based DWI sequences because of inherent spatial distortion associated with this type of MRI acquisition.


Assuntos
Imagem Multimodal , Imagem Corporal Total , Idoso , Feminino , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
10.
Magn Reson Imaging ; 31(7): 1105-11, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23684242

RESUMO

Acupuncture, which is recognized as an alternative and complementary treatment in Western medicine, has long shown efficiencies in chronic pain relief, drug addiction treatment, stroke rehabilitation and other clinical practices. The neural mechanism underlying acupuncture, however, is still unclear. Many studies have focused on the sustained effects of acupuncture on healthy subjects, yet there are very few on the topological organization of functional networks in the whole brain in response to long-duration acupuncture (longer than 20 min). This paper presents a novel study on the effects of long-duration transcutaneous electric acupoint stimulation (TEAS) on the small-world properties of brain functional networks. Functional magnetic resonance imaging was used to construct brain functional networks of 18 healthy subjects (9 males and 9 females) during the resting state. All subjects received both TEAS and minimal TEAS (MTEAS) and were scanned before and after each stimulation. An altered functional network was found with lower local efficiency and no significant change in global efficiency for healthy subjects after TEAS, while no significant difference was observed after MTEAS. The experiments also showed that the nodal efficiencies in several paralimbic/limbic regions were altered by TEAS, and those in middle frontal gyrus and other regions by MTEAS. To remove the psychological effects and the baseline, we compared the difference between diffTEAS (difference between after and before TEAS) and diffMTEAS (difference between after and before MTEAS). The results showed that the local efficiency was decreased and that the nodal efficiencies in frontal gyrus, orbitofrontal cortex, anterior cingulate gyrus and hippocampus gyrus were changed. Based on those observations, we conclude that long-duration TEAS may modulate the short-range connections of brain functional networks and also the limbic system.


Assuntos
Pontos de Acupuntura , Encéfalo/patologia , Terapia por Estimulação Elétrica/métodos , Estimulação Elétrica Nervosa Transcutânea/métodos , Adulto , Encéfalo/fisiologia , Feminino , Lobo Frontal/patologia , Giro do Cíngulo/patologia , Hipocampo/patologia , Humanos , Processamento de Imagem Assistida por Computador , Sistema Límbico/patologia , Imageamento por Ressonância Magnética , Masculino , Fatores de Tempo
11.
Invest Radiol ; 48(9): 678-86, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23563196

RESUMO

PURPOSE: The purpose of this study was to compare automated, motion-corrected, color-encoded (AMC) perfusion maps with qualitative visual analysis of adenosine stress cardiovascular magnetic resonance imaging for detection of flow-limiting stenoses. MATERIALS AND METHODS: Myocardial perfusion measurements applying the standard adenosine stress imaging protocol and a saturation-recovery temporal generalized autocalibrating partially parallel acquisition (t-GRAPPA) turbo fast low angle shot (Turbo FLASH) magnetic resonance imaging sequence were performed in 25 patients using a 3.0-T MAGNETOM Skyra (Siemens Healthcare Sector, Erlangen, Germany). Perfusion studies were analyzed using AMC perfusion maps and qualitative visual analysis. Angiographically detected coronary artery (CA) stenoses greater than 75% or 50% or more with a myocardial perfusion reserve index less than 1.5 were considered as hemodynamically relevant. Diagnostic performance and time requirement for both methods were compared. Interobserver and intraobserver reliability were also assessed. RESULTS: A total of 29 CA stenoses were included in the analysis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for detection of ischemia on a per-patient basis were comparable using the AMC perfusion maps compared to visual analysis. On a per-CA territory basis, the attribution of an ischemia to the respective vessel was facilitated using the AMC perfusion maps. Interobserver and intraobserver reliability were better for the AMC perfusion maps (concordance correlation coefficient, 0.94 and 0.93, respectively) compared to visual analysis (concordance correlation coefficient, 0.73 and 0.79, respectively). In addition, in comparison to visual analysis, the AMC perfusion maps were able to significantly reduce analysis time from 7.7 (3.1) to 3.2 (1.9) minutes (P < 0.0001). CONCLUSIONS: The AMC perfusion maps yielded a diagnostic performance on a per-patient and on a per-CA territory basis comparable with the visual analysis. Furthermore, this approach demonstrated higher interobserver and intraobserver reliability as well as a better time efficiency when compared to visual analysis.


Assuntos
Adenosina , Artefatos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico , Imagem de Perfusão do Miocárdio/métodos , Reconhecimento Automatizado de Padrão/métodos , Idoso , Teste de Esforço/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Movimento (Física) , Variações Dependentes do Observador , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Vasodilatadores
12.
J Neuroimaging ; 23(3): 484-90, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22817911

RESUMO

BACKGROUND: To investigate the reliability of a novel magnetization transfer ratio (MTR) postprocessing technique for the hippocampus using histogram analysis, and compare results to more established volumetric measurements. This study is conducted in healthy volunteers as a precursor to future applications regarding progressive neurologic diseases, such as Alzheimer's disease. METHODS: Eight healthy subjects were scanned twice with interval of 1 week using quantitative magnetic resonance imaging (MRI). Automated pixel-wise analysis was performed for the hippocampal regions of each patient. Reliability was assessed using intraclass correlation coefficients (ICCs), coefficients of variation (COVs), and instrumental standard deviation (ISD). RESULTS: Reliable metrics were 25th percentile, median, 75th percentile, peak location, and mean approach (ranges: ICC = .93-.96, COV = 2.71-3.88%, ISD .78-1.01). Histogram peak height had ICC below .7, and a COV above 10%. Volumetric measurements had (ICC = .95-.97, COV = 1.43-3.39%). CONCLUSION: Excellent scan-rescan reproducibility (ICC > .9, COV < 10%) was observed for specific MTR histogram metrics and the mean MTR approach. These results are comparable to the volumetric approach. Future studies can examine the possibility that MTR changes precede morphological changes as this study suggests that both MTR and volumetric measurements of the hippocampus can be used as reliable imaging tools.


Assuntos
Algoritmos , Hipocampo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
13.
Magn Reson Med ; 69(1): 158-62, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22392645

RESUMO

Most nonenhanced MRA techniques for evaluating peripheral artery disease (PAD) require cardiac synchronization through physiological gating. Electrocardiographic gating is the most popular method for cardiac synchronization; however, it is subject to interference from switching magnetic field gradients and radiofrequency pulses. A method is described for self-gated nonenhanced MRA that does not require the use of electrocardiographic gating. Imaging was prospectively triggered by detecting the acceleration of blood flow during systole with a reference-less phase contrast navigator. The technique was implemented for nonsubtractive nonenhanced MRA using quiescent-interval single-shot MRA. The lower extremity peripheral arteries of eight healthy subjects were imaged using electrocardiographic-, pulse-, and self-gated quiescent-interval single-shot. Self-gated quiescent-interval single-shot triggered with 99% accuracy. There were no significant differences in relative contrast, contrast-to-noise ratio, or image quality between self-gated and electrocardiographic-gated quiescent-interval single-shot MRA (P > 0.05). Image quality with pulse gating was inferior.


Assuntos
Perna (Membro)/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Doença Arterial Periférica/diagnóstico , Eletrocardiografia , Humanos
14.
Neurosci Lett ; 530(1): 12-7, 2012 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-23041713

RESUMO

This study mapped brain activity elicited by high frequency electroacupuncture by simultaneously using blood oxygenation level dependent (BOLD) and cerebral blood flow (CBF) contrasts. Forty subjects participated in the study, in which twenty ones were imaged during electrical acupoint stimulation (EAS) to the left LI4 acupoint at a maximal intensity without pain, and the others were with a minimal-EAS at a just detectible intensity. Both BOLD and CBF data were acquired simultaneously during alternating blocks of rest and stimulation. The results showed that the minimal-EAS mostly induced the activities in somatosensory region, including those in inferior parietal lobule, SII, insula, and thalamus. On the other hand, EAS activated more including also posterior middle cingulate cortex (pMCC), and deactivated superior temporal gyrus. Moreover, deactivation was found in posterior cingulated cortex (PCC), precuneus from BOLD and in culmen of cerebellum, caudate from CBF. The comparison between EAS and minimal-EAS revealed deactivation in the default mode network in both BOLD and CBF signals, activation in thalamus, insula, and caudal anterior cingulate cortex (ACC) in the CBF signal alone, and deactivation in putamen, rostral ACC and parahippocampal gyrus in the BOLD signal alone. This study provides, for the first time, simultaneous CBF and BOLD responses to high frequency EAS at the LI4 acupoint, revealing concordant and complementary insights into the neural effects of EAS, including modulation of subcortical structures and limbic system.


Assuntos
Terapia por Acupuntura/métodos , Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Imageamento por Ressonância Magnética/métodos , Adulto , Encéfalo/irrigação sanguínea , Feminino , Giro do Cíngulo/irrigação sanguínea , Giro do Cíngulo/fisiologia , Humanos , Sistema Límbico/irrigação sanguínea , Sistema Límbico/fisiologia , Masculino , Giro Para-Hipocampal/irrigação sanguínea , Giro Para-Hipocampal/fisiologia , Putamen/irrigação sanguínea , Putamen/fisiologia , Córtex Somatossensorial/irrigação sanguínea , Córtex Somatossensorial/fisiologia , Tálamo/irrigação sanguínea , Tálamo/fisiologia , Adulto Jovem
15.
J Cardiovasc Magn Reson ; 14: 30, 2012 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-22607351

RESUMO

BACKGROUND: Cardiac and navigator-gated, inversion-prepared non-enhanced magnetic resonance angiography techniques can accurately depict the renal arteries without the need for contrast administration. However, the scan time and effectiveness of navigator-gated techniques depend on the subject respiratory pattern, which at times results in excessively prolonged scan times or suboptimal image quality. A single-shot 3D magnetization-prepared steady-state free precession technique was implemented to allow the full extent of the renal arteries to be depicted within a single breath-hold. METHODS: Technical optimization of the breath-hold technique was performed with fourteen healthy volunteers. An alternative magnetization preparation scheme was tested to maximize inflow signal. Quantitative and qualitative comparisons were made between the breath-hold technique and the clinically accepted navigator-gated technique in both volunteers and patients on a 1.5 T scanner. RESULTS: The breath-hold technique provided an average of seven fold reduction in imaging time, without significant loss of image quality. Comparable single-to-noise and contrast-to-noise ratios of intra- and extra-renal arteries were found between the breath-hold and the navigator-gated techniques in volunteers. Furthermore, the breath-hold technique demonstrated good image quality for diagnostic purposes in a small number of patients in a pilot study. CONCLUSIONS: The single-shot, breath-hold technique offers an alternative to navigator-gated methods for non-enhanced renal magnetic resonance angiography. The initial results suggest a potential supplementary clinical role for the breath-hold technique in the evaluation of suspected renal artery diseases.


Assuntos
Suspensão da Respiração , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Obstrução da Artéria Renal/diagnóstico , Artéria Renal/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valores de Referência , Reprodutibilidade dos Testes , Adulto Jovem
16.
AJR Am J Roentgenol ; 198(2): 344-50, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22268176

RESUMO

OBJECTIVE: The purpose of this article is to evaluate the utility of a tool in quantifying the peak antegrade velocity when assessing patients with cardiac valvular pathology. MATERIALS AND METHODS: Directionally independent peak velocity evaluation (MaxVelocity, Siemens Healthcare) phase-contrast cardiac MRI was performed for 44 patients referred to our institution with a diagnosis or concern for aortic valvular disease or undergoing imaging for thoracic aortic aneurysm. In addition, standard through-plane phase-contrast MR angiography at the level of the aortic valve was performed. The MaxVelocity technique provides a simple tool to extract the magnitude of the peak velocity, independently of its direction, from phase-contrast imaging with velocity encoding. Recent echocardiography (within 1 month) and assessment of peak forward velocity at the level of the aortic valve were required for inclusion in the study. RESULTS: The MaxVelocity technique shows significantly lower error in estimating peak antegrade velocity at the level of the aortic valve than does standard unidirectional through-plane phase-contrast MRI, using transthoracic echocardiography as the reference noninvasive imaging method. CONCLUSION: Relative to standard through-plane imaging, MaxVelocity more closely approximates echocardiography for noninvasive assessment of peak antegrade velocity. Improved accuracy is critical for surgical decision making in patients with aortic valvular disease. Therefore, MaxVelocity provides an easy approach to quantify peak velocity as part of a routine clinical MRI protocol.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico , Velocidade do Fluxo Sanguíneo/fisiologia , Doenças das Valvas Cardíacas/diagnóstico , Angiografia por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Ecocardiografia Doppler , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Software
17.
J Magn Reson Imaging ; 35(2): 309-17, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21990125

RESUMO

PURPOSE: To enhance the reliability and spatial resolution of magnetization transfer ratio (MTR) measurements for interrogation of subcortical brain regions with an automated volume of interest (VOI) approach. MATERIALS AND METHODS: A 3D magnetization transfer (MT) sequence was acquired using a scan-rescan imaging protocol in nine healthy volunteers. VOI definition masks for the MTR measurements were generated using FreeSurfer and compared to a manual region of interest (ROI) approach. (The longitudinal stability of MTR was monitored using agar gel phantom over a 5-month period.) Intraclass correlation coefficients (ICCs), coefficients of variation (CVs), and instrumental standard deviation (ISD) were determined. RESULTS: CVs ranged from 1.29%-2.64% (automated) vs. 1.30%-3.40% (manual). ISDs ranged from 0.62-1.10 pu (automated) vs. 0.68-1.67 pu (manual). The SD of the running difference was 1.70% for the phantom scans. The Bland-Altman method indicated interchangeability of the automated VOI and manual ROI measurements. CONCLUSION: The automated VOI approach for MTR measurement yielded higher ICCs, lower CVs, and lower ISDs compared to the manual method, supporting the utility of this strategy. These results demonstrate the feasibility of obtaining reliable MTR measurements in hippocampus and other critical subcortical regions.


Assuntos
Mapeamento Encefálico/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Análise de Variância , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes
18.
AJR Am J Roentgenol ; 197(6): 1466-73, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22109304

RESUMO

OBJECTIVE: The joint guidelines of the American College of Cardiology and American Heart Association support the use of contrast-enhanced MR angiography (CEMRA) to diagnose the location and degree of stenosis in patients with known or suspected peripheral arterial disease (PAD). The high prevalence of chronic renal impairment in diabetic patients with PAD and the need for high doses of gadolinium-based contrast agents place them at risk for nephrogenic systemic fibrosis. The purpose of our study was to evaluate the accuracy of the rapid technique of quiescent-interval single-shot (QISS) unenhanced MR angiography (MRA) compared with CEMRA for the diagnosis in diabetic patients referred with symptomatic chronic PAD. SUBJECTS AND METHODS: This prospective two-center study evaluated 25 consecutive diabetic patients with documented or suspected symptomatic PAD. Both centers used identical imaging protocols. Images were independently analyzed by two radiologists. A subgroup analysis was performed of patients who were also assessed with digital subtraction angiography (DSA) as part of the standard-of-care protocol before revascularization. RESULTS: For this study, 775 segments were analyzed. On a per-segment basis, the mean values of the diagnostic accuracy of unenhanced MRA compared with reference CEMRA for two reviewers, reviewers 1 and 2, were as follows: sensitivity, 87.4% and 92.1%; specificity, 96.8% and 96.0%; positive predictive value, 90.8% and 94.0%; and negative predictive value, 95.5% and 94.6%. Substantial agreement was found when overall DSA results were compared with QISS unenhanced MRA (κ = 0.68) and CEMRA (κ = 0.63) in the subgroup of patients who also underwent DSA. There was almost perfect agreement between the two readers for stenosis scores, with Cohen's kappa values being greater than 0.80 for both MRA techniques. CONCLUSION: The results of our study indicate that QISS unenhanced MRA is an accurate noncontrast alternative to CEMRA for showing clinically significant arterial disease in patients with diabetes with symptomatic PAD.


Assuntos
Angiopatias Diabéticas/diagnóstico , Angiografia por Ressonância Magnética/métodos , Doenças Vasculares Periféricas/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Meios de Contraste , Feminino , Humanos , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Estatísticas não Paramétricas
19.
Neuroimage ; 57(2): 462-75, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21575727

RESUMO

Segregation of information flow along a dorsally directed pathway for processing object location and a ventrally directed pathway for processing object identity is well established in the visual and auditory systems, but is less clear in the somatosensory system. We hypothesized that segregation of location vs. identity information in touch would be evident if texture is the relevant property for stimulus identity, given the salience of texture for touch. Here, we used functional magnetic resonance imaging (fMRI) to investigate whether the pathways for haptic and visual processing of location and texture are segregated, and the extent of bisensory convergence. Haptic texture-selectivity was found in the parietal operculum and posterior visual cortex bilaterally, and in parts of left inferior frontal cortex. There was bisensory texture-selectivity at some of these sites in posterior visual and left inferior frontal cortex. Connectivity analyses demonstrated, in each modality, flow of information from unisensory non-selective areas to modality-specific texture-selective areas and further to bisensory texture-selective areas. Location-selectivity was mostly bisensory, occurring in dorsal areas, including the frontal eye fields and multiple regions around the intraparietal sulcus bilaterally. Many of these regions received input from unisensory areas in both modalities. Together with earlier studies, the activation and connectivity analyses of the present study establish that somatosensory processing flows into segregated pathways for location and object identity information. The location-selective somatosensory pathway converges with its visual counterpart in dorsal frontoparietal cortex, while the texture-selective somatosensory pathway runs through the parietal operculum before converging with its visual counterpart in visual and frontal cortex. Both segregation of sensory processing according to object property and multisensory convergence appear to be universal organizing principles.


Assuntos
Mapeamento Encefálico , Encéfalo/anatomia & histologia , Vias Neurais/anatomia & histologia , Percepção do Tato/fisiologia , Percepção Visual/fisiologia , Adolescente , Encéfalo/fisiologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Vias Neurais/fisiologia , Adulto Jovem
20.
Invest Ophthalmol Vis Sci ; 51(12): 6826-34, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20631240

RESUMO

PURPOSE: Activity in regions of the visual cortex corresponding to central scotomas in subjects with macular degeneration (MD) is considered evidence for functional reorganization in the brain. Three unresolved issues related to cortical activity in subjects with MD were addressed: Is the cortical response to stimuli presented to the preferred retinal locus (PRL) different from other retinal loci at the same eccentricity? What effect does the role of age of onset and etiology of MD have on cortical responses? How do functional responses in an MD subject's visual cortex vary for task and stimulus conditions? METHODS: Eight MD subjects-four with age-related onset (AMD) and four with juvenile onset (JMD)-and two age-matched normal vision controls, participated in three testing conditions while undergoing functional magnetic resonance imaging (fMRI). First, subjects viewed a small stimulus presented at the PRL compared with a non-PRL control location to investigate the role of the PRL. Second, they viewed a full-field flickering checkerboard compared with a small stimulus in the original fovea to investigate brain activation with passive viewing. Third, they performed a one-back task with scene images to investigate brain activation with active viewing. RESULTS: A small stimulus at the PRL generated more extensive cortical activation than at a non-PRL location, but neither yielded activation in the foveal cortical projection. Both passive and active viewing of full-field stimuli left a silent zone at the posterior pole of the occipital cortex, implying a lack of complete cortical reorganization. The silent zone was smaller in the task requiring active viewing compared with the task requiring passive viewing, especially in JMD subjects. CONCLUSIONS: The PRL for MD subjects has more extensive cortical representation than a retinal region with matched eccentricity. There is evidence for incomplete functional reorganization of early visual cortex in both JMD and AMD. Functional reorganization is more prominent in JMD. Feedback signals, possibly associated with attention, play an important role in the reorganization.


Assuntos
Degeneração Macular/fisiopatologia , Retina/fisiopatologia , Córtex Visual/fisiopatologia , Percepção Visual/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Sensibilidades de Contraste , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Plasticidade Neuronal/fisiologia , Escotoma/fisiopatologia , Doença de Stargardt , Acuidade Visual , Testes de Campo Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...