Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 57(6): 1685-700, 2012 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-22398310

RESUMO

The imaging performance of a high-resolution preclinical micro-positron emission tomography (micro-PET) system employing liquid xenon (LXe) as the gamma-ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection ionization chambers and two arrays of large area avalanche photodiodes for the measurement of ionization charge and scintillation light. A key feature of the LXePET system is the ability to identify individual photon interactions with high energy resolution and high spatial resolution in three dimensions and determine the correct interaction sequence using Compton reconstruction algorithms. The simulated LXePET imaging performance was evaluated by computing the noise equivalent count rate, the sensitivity and point spread function for a point source according to the NEMA-NU4 standard. The image quality was studied with a micro-Derenzo phantom. Results of these simulation studies included noise equivalent count rate peaking at 1326 kcps at 188 MBq (705 kcps at 184 MBq) for an energy window of 450-600 keV and a coincidence window of 1 ns for mouse (rat) phantoms. The absolute sensitivity at the center of the field of view was 12.6%. Radial, tangential and axial resolutions of (22)Na point sources reconstructed with a list-mode maximum likelihood expectation maximization algorithm were ≤0.8 mm (full-width at half-maximum) throughout the field of view. Hot-rod inserts of <0.8 mm diameter were resolvable in the transaxial image of a micro-Derenzo phantom. The simulations show that a LXe system would provide new capabilities for significantly enhancing PET images.


Assuntos
Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Algoritmos , Animais , Fenômenos Biofísicos , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Camundongos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Ratos , Xenônio
2.
Phys Rev Lett ; 106(5): 052501, 2011 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-21405386

RESUMO

We measured with unprecedented precision the induced polarization P(y) in (4)He(e,e'p)(3)H at Q(2)=0.8 and 1.3 (GeV/c)(2). The induced polarization is indicative of reaction-mechanism effects beyond the impulse approximation. Our results are in agreement with a relativistic distorted-wave impulse approximation calculation but are overestimated by a calculation with strong charge-exchange effects. Our data are used to constrain the strength of the spin-independent charge-exchange term in the latter calculation.

3.
Phys Rev Lett ; 105(7): 072001, 2010 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-20868031

RESUMO

Proton recoil polarization was measured in the quasielastic 4He(e,e'p)3H reaction at Q{2}=0.8 and 1.3 (GeV/c){2} with unprecedented precision. The polarization-transfer coefficients are found to differ from those of the 1H(e,e'p) reaction, contradicting a relativistic distorted-wave approximation and favoring either the inclusion of medium-modified proton form factors predicted by the quark-meson coupling model or a spin-dependent charge-exchange final-state interaction. For the first time, the polarization-transfer ratio is studied as a function of the virtuality of the proton.

4.
Phys Rev Lett ; 99(20): 202002, 2007 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-18233135

RESUMO

High-precision measurements of the proton elastic form-factor ratio, mu pG p E/G p M, have been made at four-momentum transfer, Q2, values between 0.2 and 0.5 GeV2. The new data, while consistent with previous results, clearly show a ratio less than unity and significant differences from the central values of several recent phenomenological fits. By combining the new form-factor ratio data with an existing cross-section measurement, one finds that in this Q2 range the deviation from unity is primarily due to G p E being smaller than expected.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...