Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 257(8): 1649-1659, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31139918

RESUMO

BACKGROUND/OBJECTIVES: To assess the efficacy of dynamic intraoperative spectral-domain optical coherence tomography (iSD-OCT) imaging for inverted internal limiting membrane (ILM) flap technique (IILMFT) in large macular hole (MH) surgery. SUBJECTS/METHODS: Prospective, non-randomized, observational study was conducted on 8 eyes of 7 patients with large, chronic and recurrent MHs, which were treated by pars plana vitrectomy (PPV) with IILMFT. All patients underwent standard pre- and postoperative examination. The iSD-OCT imaging was performed using microscope integrated systems before, during, and after ILM peeling. The iSD-OCT data were post-processed using graphic software and reviewed for tissue behavior and instruments position. RESULTS: The real-time iSD-OCT-assisted IILMFT allowed for real-time imaging of the entire surgery with visualization of the MH, vitreoretinal instruments, and all steps of inverted ILM flap formation. In spite of shadowing created by the steel instruments, it was possible to follow and control the distance between the instrument tips and retinal layers. Dynamic imaging of the surgical maneuvers including ILM peeling and mechanical apposition of MH edges revealed the iatrogenic impact on the retina (depression and appearance of hyporeflective zones). iSD-OCT imaging could confirm the proper position of the inverted ILM flap at the very end of the surgery after fluid-air exchange. CONCLUSIONS: iSD-OCT imaging is an effective tool for learning and performing a well-controlled and safe inverted ILM flap technique in patients with large MH. Clinical significance of the structural iSD-OCT findings has to be further studied.


Assuntos
Membrana Basal/transplante , Macula Lutea/patologia , Perfurações Retinianas/cirurgia , Retalhos Cirúrgicos , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Vitrectomia/métodos , Adulto , Idoso , Feminino , Seguimentos , Humanos , Período Intraoperatório , Macula Lutea/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Perfurações Retinianas/diagnóstico , Resultado do Tratamento
2.
BMC Ophthalmol ; 17(1): 134, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28764684

RESUMO

BACKGROUND: The pathogenesis of non-rhegmatogenous retinal detachment (non-RRD) associated with morning glory syndrome (MGS) is not established, as well as best surgical approach to treat RD. Our purpose was to analyse intraoperative optical coherence tomography data (iOCT) in all steps of pars plana vitrectomy (PPV) for non-RRD in MGS, in order to follow pathophysiological aspects of the disease and to understand the tissues behaviour during surgical workflow. CASE PRESENTATION: Intraoperative spectral domain optical coherent tomography (iSD-OCT) assisted PPV using Rescan 700 (Carl Zeiss Meditech, Jena, Germany) with epiretinal membrane (ERM) and internal retinal membrane (ILM) peeling, and air endotamponade was performed on the only eye of a 21 years old female with non-RRD associated with MGS. BCVA, pre-, intra- and postoperative OCT were performed along with standard ocular examination. iOCT video and snapshots were analysed intra- and postoperatively using post-processing approach using graphic software. The progression of non-RRD resulted in best corrected visual acuity (BCVA) decrease from 0.8 to 0.2. Triamcinolone enhanced iOCT imaging revealed strong vitreous traction and adhesion above the macula and optic disc. Internal limiting membrane was peeled under iOCT control to prevent the peeling of inner layers of the retinal schisis. No retinal break was detected, and only air endotamponade was performed. The retina reattached during first 4 weeks of follow-up with gradual resolution of intraretinal- and subretinal fluid, and remained stable in 12 months. BCVA improved to 0.8. CONCLUSION: Based on iSD-OCT findings we assume that non-RRD in this case of MGS is caused primarily by the vitreous traction with further possible formation of the retinal breaks. Retinal reattachment reached only with air endotamponade strongly advocates the tractional component of non-RRD and retinal schisis assotiated with MGS. Early PPV for central non-RRD and retinal schisis with the use of iOCT can be performed in more safe and controlled manner and has to be considered to reduce the risk of retinal break formation and to prevent the central vision loss.


Assuntos
Disco Óptico/anormalidades , Doenças do Nervo Óptico/complicações , Retina/patologia , Descolamento Retiniano/cirurgia , Cirurgia Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Vitrectomia/métodos , Feminino , Humanos , Doenças do Nervo Óptico/congênito , Doenças do Nervo Óptico/diagnóstico , Descolamento Retiniano/diagnóstico , Descolamento Retiniano/etiologia , Síndrome , Acuidade Visual , Adulto Jovem
3.
J Cataract Refract Surg ; 42(5): 694-702, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27255245

RESUMO

PURPOSE: To assess the position of intraocular lenses (IOLs) at the end of standard phacoemulsification with intraoperative spectral-domain optical coherence tomography (SD-OCT). SETTINGS: Department of Ophthalmology, Rudolf Foundation Hospital, Vienna, Austria. DESIGN: Prospective case series. METHODS: Standard phacoemulsification with IOL implantation was performed. The Rescan 700 SD-OCT system was used for intraoperative imaging. The anterior segment of the eye was scanned using SD-OCT at the end of the surgery. The distance from the IOL optic center and the IOL optic edge to the posterior capsule was measured postoperatively using graphic software. RESULTS: The study comprised 74 patients (101 eyes). The mean axial length was 23.97 mm (range 21.43 to 28.61 mm). The mean IOL power was 20.39 diopters (D) (range 6.5 to 27.5 D). Contact between the IOL and posterior capsule was absent in 88 cases (87.13%), and partial or full contact was present in 13 cases (12.87%). The mean distance between the IOL central optic and posterior capsule was 0.71 pixel (range 0.06 to 1.38 pixels) in 99 cases (98.02%). In 42 cases (57.53%), partial contact between the IOL edges and the posterior capsule was noticed. The mean distance between the IOL edge and posterior capsule was 0.21 pixel (range 0.04 to 0.92 pixel). CONCLUSIONS: Intraoperative SD-OCT facilitated the imaging of IOL position during standard phacoemulsification. Contact between the IOL central optic and posterior capsule at the end of the surgery occurred rarely. Improved IOL design should be considered. FINANCIAL DISCLOSURE: Drs. Binder and Glittenberg are consultants to Carl Zeiss Meditech AG. None of the other authors has a financial or proprietary interest in any material or method mentioned.


Assuntos
Implante de Lente Intraocular , Facoemulsificação , Tomografia de Coerência Óptica , Humanos , Lentes Intraoculares , Complicações Pós-Operatórias , Estudos Prospectivos , Desenho de Prótese
4.
Acta Ophthalmol ; 87(1): 89-93, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18494741

RESUMO

PURPOSE: Melatonin (N-acetyl-5-methoxytryptamine) (MT) is a hormone that acts as an antioxidant. It is produced by the pineal gland and within the retina; its release is blocked by light entering the eye. We examined whether MT daytime levels differ between pseudophakic patients with age-related macular degeneration (ARMD) and pseudophakic subjects without any ocular pathology of the same age. METHODS: A prospective, cross-sectional, observational study was performed. Pseudophakic patients of the same age group were included. Patients underwent complete ophthalmic examinations and blood sampling between 08:00 and 10:00 hr. MT daytime value in the serum was the main outcome measure. RESULTS: Sixty-nine pseudophakic patients were included. Fifty patients with exudative and non-exudative ARMD were in the study group while 19 patients were controls. Patients with ARMD had significantly higher daytime levels of MT (P = 0.003). There were significant differences in MT daytime levels between the exudative and non-exudative forms (P = 0.009). MT values also correlated with the best-corrected visual acuity (r = -0.285, P = 0.019). CONCLUSION: These data indicate that pseudophakic patients with ARMD produce more MT during the day compared to pseudophakic subjects without ARMD. This may be caused by the reduced visual acuity in patients with ARMD, whereby less light reaches the photoreceptors, allowing MT secretion to continue during the day. Because MT also acts as an antioxidant and daytime levels are higher in patients with ARMD, these results might be interpreted as a rescue factor.


Assuntos
Ritmo Circadiano/fisiologia , Degeneração Macular/sangue , Melatonina/sangue , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Pseudofacia/sangue , Estações do Ano , Acuidade Visual/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...