Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Health Technol Assess ; 17(51): 1-142, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24225334

RESUMO

OBJECTIVES: To determine the best photographic surrogate markers for detecting sight-threatening macular oedema (MO) in people with diabetes attending UK national screening programmes. DESIGN: A multicentre, prospective, observational cohort study of 3170 patients with photographic signs of diabetic retinopathy visible within the macular region [exudates within two disc diameters, microaneurysms/dot haemorrhages (M/DHs) and blot haemorrhages (BHs)] who were recruited from seven study centres. SETTING: All patients were recruited and imaged at one of seven study centres in Aberdeen, Birmingham, Dundee, Dunfermline, Edinburgh, Liverpool and Oxford. PARTICIPANTS: Subjects with features of diabetic retinopathy visible within the macular region attending one of seven diabetic retinal screening programmes. INTERVENTIONS: Alternative referral criteria for suspected MO based on photographic surrogate markers; an optical coherence tomographic examination in addition to the standard digital retinal photograph. MAIN OUTCOME MEASURES: (1) To determine the best method to detect sight-threatening MO in people with diabetes using photographic surrogate markers. (2) Sensitivity and specificity estimates to assess the costs and consequences of using alternative strategies. (3) Modelled long-term costs and quality-adjusted life-years (QALYs). RESULTS: Prevalence of MO was strongly related to the presence of lesions and was roughly five times higher in subjects with exudates or BHs or more than two M/DHs within one disc diameter. Having worse visual acuity was associated with about a fivefold higher prevalence of MO. Current manual screening grading schemes that ignore visual acuity or the presence of M/DHs could be improved by taking these into account. Health service costs increase substantially with more sensitive/less specific strategies. A fully automated strategy, using the automated detection of patterns of photographic surrogate markers, is superior to all current manual grading schemes for detecting MO in people with diabetes. The addition of optical coherence tomography (OCT) to each strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. CONCLUSIONS: Compared with all current manual grading schemes, for the same sensitivity, a fully automated strategy, using the automated detection of patterns of photographic surrogate markers, achieves a higher specificity for detecting MO in people with diabetes, especially if visual acuity is included in the automated strategy. Overall, costs to the health service are likely to increase if more sensitive referral strategies are adopted over more specific screening strategies for MO, for only very small gains in QALYs. The addition of OCT to each screening strategy, prior to referral, results in a reduction in costs to the health service with no decrement in the number of MO cases detected. STUDY REGISTRATION: This study has been registered as REC/IRAS 07/S0801/107, UKCRN ID 9063 and NIHR HTA 06/402/49. SOURCE OF FUNDING: This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 17, No. 51. See the HTA programme website for further project information.


Assuntos
Retinopatia Diabética/diagnóstico , Edema Macular/diagnóstico , Programas de Rastreamento/economia , Fotografação/economia , Tomografia de Coerência Óptica/economia , Adulto , Automação/economia , Automação/métodos , Biomarcadores , Retinopatia Diabética/economia , Feminino , Humanos , Edema Macular/economia , Masculino , Programas de Rastreamento/métodos , Fotografação/métodos , Estudos Prospectivos , Melhoria de Qualidade/economia , Sensibilidade e Especificidade , Tomografia de Coerência Óptica/métodos , Reino Unido
2.
Diabet Med ; 29(6): 776-83, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22023553

RESUMO

AIMS: To develop and evaluate an image grading external quality assurance system for the Scottish Diabetic Retinopathy Screening Programme. METHOD: A web-based image grading system was developed which closely matches the current Scottish national screening software. Two rounds of external quality assurance were run in autumn 2008 and spring 2010, each time using the same 100 images. Graders were compared with a consensus standard derived from the top-level graders' results. After the first round, the centre lead clinicians and top-level graders reviewed the results and drew up guidance notes for the second round. RESULTS: Grader sensitivities ranged from 60.0 to 100% (median 92.5%) in 2008, and from 62.5 to 100% (median 92.5%) in 2010. Specificities ranged from 34.0 to 98.0% (median 86%) in 2008, and 54.0 to 100% (median 88%) in 2010. There was no difference in sensitivity between grader levels, but first-level graders had a significantly lower specificity than level-two and level-three graders. In 2008, one centre had a lower sensitivity but higher specificity than the majority of centres. Following the feedback from the first round, overall agreement improved in 2010 and there were no longer any significant differences between centres. CONCLUSIONS: A useful educational tool has been developed for image grading external quality assurance.


Assuntos
Retinopatia Diabética/diagnóstico , Aumento da Imagem/normas , Internet , Programas de Rastreamento , Garantia da Qualidade dos Cuidados de Saúde/normas , Auditoria Clínica , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Fotografação/métodos , Reprodutibilidade dos Testes , Escócia/epidemiologia , Sensibilidade e Especificidade , Software
3.
Br J Ophthalmol ; 94(6): 712-9, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19965826

RESUMO

AIMS: To assess the cost-effectiveness of an improved automated grading algorithm for diabetic retinopathy against a previously described algorithm, and in comparison with manual grading. METHODS: Efficacy of the alternative algorithms was assessed using a reference graded set of images from three screening centres in Scotland (1253 cases with observable/referable retinopathy and 6333 individuals with mild or no retinopathy). Screening outcomes and grading and diagnosis costs were modelled for a cohort of 180 000 people, with prevalence of referable retinopathy at 4%. Algorithm (b), which combines image quality assessment with detection algorithms for microaneurysms (MA), blot haemorrhages and exudates, was compared with a simpler algorithm (a) (using image quality assessment and MA/dot haemorrhage (DH) detection), and the current practice of manual grading. RESULTS: Compared with algorithm (a), algorithm (b) would identify an additional 113 cases of referable retinopathy for an incremental cost of pound 68 per additional case. Compared with manual grading, automated grading would be expected to identify between 54 and 123 fewer referable cases, for a grading cost saving between pound 3834 and pound 1727 per case missed. Extrapolation modelling over a 20-year time horizon suggests manual grading would cost between pound 25,676 and pound 267,115 per additional quality adjusted life year gained. CONCLUSIONS: Algorithm (b) is more cost-effective than the algorithm based on quality assessment and MA/DH detection. With respect to the value of introducing automated detection systems into screening programmes, automated grading operates within the recommended national standards in Scotland and is likely to be considered a cost-effective alternative to manual disease/no disease grading.


Assuntos
Retinopatia Diabética/diagnóstico , Diagnóstico por Computador/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Índice de Gravidade de Doença , Algoritmos , Análise Custo-Benefício , Árvores de Decisões , Retinopatia Diabética/complicações , Retinopatia Diabética/economia , Diagnóstico por Computador/métodos , Técnicas de Diagnóstico Oftalmológico , Exsudatos e Transudatos/metabolismo , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Programas de Rastreamento/economia , Programas de Rastreamento/métodos , Anos de Vida Ajustados por Qualidade de Vida , Hemorragia Retiniana/etiologia , Escócia
4.
Br J Ophthalmol ; 91(11): 1518-23, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17585001

RESUMO

AIMS: National screening programmes for diabetic retinopathy using digital photography and multi-level manual grading systems are currently being implemented in the UK. Here, we assess the cost-effectiveness of replacing first level manual grading in the National Screening Programme in Scotland with an automated system developed to assess image quality and detect the presence of any retinopathy. METHODS: A decision tree model was developed and populated using sensitivity/specificity and cost data based on a study of 6722 patients in the Grampian region. Costs to the NHS, and the number of appropriate screening outcomes and true referable cases detected in 1 year were assessed. RESULTS: For the diabetic population of Scotland (approximately 160,000), with prevalence of referable retinopathy at 4% (6400 true cases), the automated strategy would be expected to identify 5560 cases (86.9%) and the manual strategy 5610 cases (87.7%). However, the automated system led to savings in grading and quality assurance costs to the NHS of 201,600 pounds per year. The additional cost per additional referable case detected (manual vs automated) totalled 4088 pounds and the additional cost per additional appropriate screening outcome (manual vs automated) was 1990 pounds. CONCLUSIONS: Given that automated grading is less costly and of similar effectiveness, it is likely to be considered a cost-effective alternative to manual grading.


Assuntos
Retinopatia Diabética/diagnóstico , Programas de Rastreamento/economia , Índice de Gravidade de Doença , Adulto , Idoso , Análise Custo-Benefício , Árvores de Decisões , Retinopatia Diabética/economia , Feminino , Custos de Cuidados de Saúde/estatística & dados numéricos , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Avaliação de Programas e Projetos de Saúde , Escócia , Medicina Estatal/economia
5.
Br J Ophthalmol ; 91(11): 1512-7, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17504851

RESUMO

AIM: To assess the efficacy of automated "disease/no disease" grading for diabetic retinopathy within a systematic screening programme. METHODS: Anonymised images were obtained from consecutive patients attending a regional primary care based diabetic retinopathy screening programme. A training set of 1067 images was used to develop automated grading algorithms. The final software was tested using a separate set of 14 406 images from 6722 patients. The sensitivity and specificity of manual and automated systems operating as "disease/no disease" graders (detecting poor quality images and any diabetic retinopathy) were determined relative to a clinical reference standard. RESULTS: The reference standard classified 8.2% of the patients as having ungradeable images (technical failures) and 62.5% as having no retinopathy. Detection of technical failures or any retinopathy was achieved by manual grading with 86.5% sensitivity (95% confidence interval 85.1 to 87.8) and 95.3% specificity (94.6 to 95.9) and by automated grading with 90.5% sensitivity (89.3 to 91.6) and 67.4% specificity (66.0 to 68.8). Manual and automated grading detected 99.1% and 97.9%, respectively, of patients with referable or observable retinopathy/maculopathy. Manual and automated grading detected 95.7% and 99.8%, respectively, of technical failures. CONCLUSION: Automated "disease/no disease" grading of diabetic retinopathy could safely reduce the burden of grading in diabetic retinopathy screening programmes.


Assuntos
Retinopatia Diabética/diagnóstico , Índice de Gravidade de Doença , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Avaliação de Programas e Projetos de Saúde , Sensibilidade e Especificidade
6.
Br J Ophthalmol ; 90(9): 1197-202, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16929064

RESUMO

Macular oedema is associated with several conditions that lead to blindness. Accurate measurement of macular thickness is important in order to follow disease progression and evaluate treatments. Four techniques are examined to determine the best reference standard for the detection and quantification of macular oedema: ultrasound, optical coherence tomography, the retinal thickness analyser, and the scanning laser ophthalmoscope. The three optical techniques have the highest resolution and sensitivity, in particular optical coherence tomography. Ultrasound can be useful where dense opacities preclude optical imaging.


Assuntos
Edema Macular/diagnóstico , Humanos , Edema Macular/diagnóstico por imagem , Edema Macular/patologia , Oftalmoscopia , Reprodutibilidade dos Testes , Retina/patologia , Sensibilidade e Especificidade , Tomografia de Coerência Óptica , Ultrassonografia
7.
Health Technol Assess ; 7(30): 1-119, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14604499

RESUMO

OBJECTIVES: To assess the performance of digital imaging, compared with other modalities, in screening for and monitoring the development of diabetic retinopathy. DESIGN: All imaging was acquired at a hospital assessment clinic. Subsequently, study optometrists examined the patients in their own premises. A subset of patients also had fluorescein angiography performed every 6 months. SETTING: Research clinic at the hospital eye clinic and optometrists' own premises. PARTICIPANTS: Study comprised 103 patients who had type 1 diabetes mellitus, 481 had type 2 diabetes mellitus and two had secondary diabetes mellitus; 157 (26.8%) had some form of retinopathy ('any') and 58 (9.9%) had referable retinopathy. INTERVENTIONS: A repeat assessment was carried out of all patients 1 year after their initial assessment. Patients who had more severe forms of retinopathy were monitored more frequently for evidence of progression. MAIN OUTCOME MEASURES: Detection of retinopathy, progression of retinopathy and determination of when treatment is required. RESULTS: Manual grading of 35-mm colour slides produced the highest sensitivity and specificity figures, with optometrist examination recording most false negatives. Manual and automated analysis of digital images had intermediate sensitivity. Both manual grading of 35-mm colour slides and digital images gave sensitivities of over 90% with few false positives. Digital imaging produced 50% fewer ungradable images than colour slides. This part of the study was limited as patients with the more severe levels of retinopathy opted for treatment. There was an increase in the number of microaneurysms in those patients who developed from mild to moderate. There was no difference between the turnover rate of either new or regressed microaneurysms for patients with mild or with sight-threatening retinopathy. It was not possible in this study to ascertain whether digital imaging systems determine when treatment is warranted. CONCLUSIONS: In the context of a national screening programme for referable retinopathy, digital imaging is an effective method. In addition, technical failure rates are lower with digital imaging than conventional photography. Digital imaging is also a more sensitive technique than slit-lamp examination by optometrists. Automated grading can improve efficiency by correctly identifying just under half the population as having no retinopathy. Recommendations for future research include: investigating whether the nasal field is required for grading; a large screening programme is required to ascertain if automated grading can safely perform as a first-level grader; if colour improves the performance of grading digital images; investigating methods to ensure effective uptake in a diabetic retinopathy screening programme.


Assuntos
Retinopatia Diabética/diagnóstico por imagem , Intensificação de Imagem Radiográfica/economia , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 2/complicações , Retinopatia Diabética/complicações , Retinopatia Diabética/fisiopatologia , Retinopatia Diabética/terapia , Progressão da Doença , Pesquisa sobre Serviços de Saúde , Humanos , Fatores de Risco , Reino Unido
8.
Diabet Med ; 20(7): 528-34, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12823232

RESUMO

AIMS: To compare the respective performances of digital retinal imaging, fundus photography and slit-lamp biomicroscopy performed by trained optometrists, in screening for diabetic retinopathy. To assess the potential contribution of automated digital image analysis to a screening programme. METHODS: A group of 586 patients recruited from a diabetic clinic underwent three or four mydriatic screening methods for retinal examination. The respective performances of digital imaging (n=586; graded manually), colour slides (n=586; graded manually), and slit-lamp examination by specially trained optometrists (n=485), were evaluated against a reference standard of slit-lamp biomicroscopy by ophthalmologists with a special interest in medical retina. The performance of automated grading of the digital images by computer was also assessed. RESULTS: Slit-lamp examination by optometrists for referable diabetic retinopathy achieved a sensitivity of 73% (52-88) and a specificity of 90% (87-93). Using two-field imaging, manual grading of red-free digital images achieved a sensitivity of 93% (82-98) and a specificity of 87% (84-90), and for colour slides, a sensitivity of 96% (87-100) and a specificity of 89% (86-91). Almost identical results were achieved for both methods with single macular field imaging. Digital imaging had a lower technical failure rate (4.4% of patients) than colour slide photography (11.9%). Applying an automated grading protocol to the digital images detected any retinopathy, with a sensitivity of 83% (77-89) and a specificity of 71% (66-75) and diabetic macular oedema with a sensitivity of 76% (53-92) and a specificity of 85% (82-88). CONCLUSIONS: Both manual grading methods produced similar results whether using a one- or two-field protocol. Technical failures rates, and hence need for recall, were lower with digital imaging. One-field grading of fundus photographs appeared to be as effective as two-field. The optometrists achieved the lowest sensitivities but reported no technical failures. Automated grading of retinal images can improve efficiency of resource utilization in diabetic retinopathy screening.


Assuntos
Retinopatia Diabética/diagnóstico , Programas de Rastreamento/métodos , Fotografação/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Diagnóstico Oftalmológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Optometria/métodos , Sensibilidade e Especificidade
9.
Nucl Med Commun ; 23(11): 1057-64, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12411833

RESUMO

Methods for quantifying the changes in brain function observed in single photon emission computed tomography (SPECT) using hexamethylenepropylene amine oxime (HMPAO) for patients with Alzheimer's disease have the potential of improving the diagnostic accuracy of the procedure and its ability to monitor response to treatment. The absolute percentage uptake of HMPAO and the cerebral perfusion volume (CPV) of the brain were assessed using SPECT in 26 patients with mild to moderate Alzheimer's disease (AD) and 24 control subjects. A subset of 15 control subjects, which was age-matched to the AD patients, was selected to allow fair statistical comparison of parameters between groups. The percentage of brain volume with reduced perfusion (R) and a volume loss index (VLI), given by /CPV, were also calculated. Eight of the control subjects were studied on a second occasion after a mean period of 6 months. There was no significant difference in percentage uptake between controls and AD patients, the mean value being 5.8%. Cerebral perfusion volume in controls was found to depend on sex (mean value in males and females being 1327 ml and 1222 ml, respectively) and on age. The volume loss index corrected for age and sex provided good discrimination between controls and AD subjects giving a sensitivity and specificity of 81% and 96%, respectively. The repeatability coefficient, the 95% confidence limit for the difference between repeat measurements, on controls was 67 ml (5%). The measurement of cerebral perfusion volume and related indices may be of value in identifying patients with early Alzheimer's disease and in following their response to treatment.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Tecnécio Tc 99m Exametazima , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Envelhecimento , Circulação Cerebrovascular , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos , Fatores Sexuais
10.
Nucl Med Commun ; 21(12): 1095-102, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11200013

RESUMO

The development of coincidence positron imaging using a gamma camera should significantly increase PET utilization. This study has compared the performance of three such systems with each other and with an equivalent single photon emission computed tomography (SPECT) measurement. A Carlson phantom, which consisted of a 20 cm diameter cylinder containing areas of uniform activity, hot lesions, cold lesions and orthogonal alternate hot and cold lines, was filled with an activity of 18F chosen to try and best exploit each camera and imaged for a fixed time (27 min). The image quality of 9 mm thick slices in each section of the phantom was compared visually. Several image quality parameters were also compared including line source resolution and noise equivalent count rate. There were considerable differences in PET image quality between the three cameras but all were at least as good as the SPECT image. The full width at half maximum (FWHM) resolution of all systems was similar (approximately 4.5 mm) but the maximum noise equivalent count rates in a 20 cm cylinder were significantly different (6.3, 2.6 and 1.6 kcps) (where cps is counts per second) and correlated with the phantom image quality.


Assuntos
Câmaras gama , Tomografia Computadorizada de Emissão/instrumentação , Radioisótopos de Flúor , Processamento de Imagem Assistida por Computador , Modelos Anatômicos , Espalhamento de Radiação , Contagem de Cintilação , Tomografia Computadorizada de Emissão de Fóton Único
11.
Phys Med Biol ; 44(7): 1625-38, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10442701

RESUMO

Detailed information on biological branching networks (optical nerves, airways or blood vessels) is often required to improve the analysis of 3D medical imaging data. A semi-automated algorithm has been developed to obtain the full 3D topology and dimensions (direction cosine, length, diameter, branching and gravity angles) of branching networks using their CT images. It has been tested using CT images of a simple Perspex branching network and applied to the CT images of a human cast of the airway tree. The morphology and topology of the computer derived network were compared with the manually measured dimensions. Good agreement was found. The airways dimensions also compared well with previous values quoted in literature. This algorithm can provide complete data set analysis much more quickly than manual measurements. Its use is limited by the CT resolution which means that very small branches are not visible. New data are presented on the branching angles of the airway tree.


Assuntos
Pulmão/diagnóstico por imagem , Modelos Anatômicos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Automação , Humanos , Imagens de Fantasmas , Plásticos , Cintilografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Eur J Vasc Endovasc Surg ; 9(3): 319-26, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7620959

RESUMO

AIM: To evaluate angioscopy in this Unit with respect to its application in lower limb vascular reconstructions. By providing magnified, colour images of the luminal surfaces of vein grafts, anastomoses and native arteries, angioscopy allows direct visualisation of imperfections and is sensitive in diagnosing technical problems. However, assessment is qualitative and magnification of the image can distort the operator's impression of true size. Angioscopy would be more versatile if it were possible to quantify the observed images. METHOD: A new technique has been developed to measure intra-luminal diameter from the angioscopic images. A linear displacement transducer is attached to the angioscope and accurately monitors its axial shift. Signals from the transducer are received by a personal computer equipped with a video frame grabber and analogue digital converter, together with appropriate software. The computer generates calculated dimensions based on geometrical principles, once each angioscope has been appropriately calibrated at the outset. RESULTS: Laboratory studies examining tubes of known dimensions have confirmed the reproducibility and accuracy of the technique. Simultaneous angioscopic and Duplex ultrasound measurements of the internal diameters of segments of vein suspended in a water bath were then carried out. Using the Duplex results as the 'gold standard', there was a strong correlation between the measurements obtained with the two techniques (Rs = 0.92). CONCLUSIONS: In the clinical context, this system has the capability to generate accurate endoluminal measurements during angioscopy. This has application for quality control in the selection of veins and inspection of run-off vessels during bypass grafting and in completion studies, following both operative and percutaneous procedures.


Assuntos
Angioscopia/métodos , Processamento de Imagem Assistida por Computador , Veia Safena/anatomia & histologia , Ultrassonografia Doppler Dupla/métodos , Conversão Análogo-Digital , Prótese Vascular , Humanos , Modelos Estruturais , Veia Safena/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...