Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Reprod Fertil ; 2(1): R27-R34, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-35128443

RESUMO

Today periodontal health is considered as an integral part of systemic health itself and no longer as a single factor. The literature recognizes that the presence of periodontal disease can represent a risk factor for numerous systemic conditions such as heart disease and diabetes. In recent years, we have witnessed a progressive interest regarding the influence exerted by this condition on reproduction, as well as the possible repercussions on conception possibilities. Upon analyzing a limited number of studies available for the correlation between periodontal disease and female infertility, it could be inferred that this condition can be equated to the presence of a real outbreak of infection and therefore exert its influence, not only through bacterial translocation in the bloodstream, causing the systemic dissemination of pathogens, but also through the production of cytokines and immunoglobulins by inflammatory mediators. This situation limits bacterial growth, but it could cause damage to the fetus, to the reproductive system, and could hinder conception attempts. Although further research is needed to better clarify the mechanism underlying the possible correlation between periodontal disease and female infertility, the present article aims to review all the available literature on this topic. LAY SUMMARY: In recent years, interest regarding the influence of gum disease on conception has increased. Since serious gum disease (periodontitis) can be compared to an outbreak of infection, studies suggest that the bacteria that mediate inflammation do not remain confined only to the gum tissue, but can enter the bloodstream and spread, thus spreading the infection and having a whole-body effect. This situation could cause damage to the developing baby, to the reproductive system and could hinder conception attempts. Constant maintenance of oral health is definitely necessary. It is important for the professionals involved (gynecologists, obstetricians, dentists, etc.) to communicate and collaborate on these issues. Dentists could advise on the correct hygienic maintenance not only to pregnant women, but also to those who are planning a pregnancy in order to avoid the occurrence of unfavorable conditions.


Assuntos
Doenças da Gengiva , Infertilidade Feminina , Doenças Periodontais , Periodontite , Feminino , Humanos , Inflamação , Gravidez
2.
Int J Oral Maxillofac Implants ; 28(3): 687-93, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23748298

RESUMO

PURPOSE: The purpose of this study was to investigate the marginal precision of computer numeric control-milled frameworks fabricated of grade 4 commercially pure titanium or cobalt-chrome alloy through digital technology and to compare them with conventional cast frameworks. MATERIAL AND METHODS: A titanium cast of a mandibular arch with six implant analogs was used as a master. The master cast was measured with a coordinate measuring machine. Fifteen rigid anatomic frameworks were created on the master cast in cast gold alloy and milled in titanium or cobalt-chrome material. The fifteen anatomic frameworks were measured in the same manner as the master cast. While the milled frameworks were measured once, at the end of the milling process, the cast anatomic frameworks were measured twice: immediately after the casting and divesting procedures and again after a technical adaptation procedure. Each anatomic framework was weighed. To compare the measurements obtained from each group of frameworks, descriptive statistics were calculated and one-way analysis of variance was performed, with values considered statistically significant at P < .05. RESULTS: The mean weight of the cast frameworks was 33.41 g, the cobalt-chrome frameworks weighed 18.12 g on average, and the titanium frameworks averaged 8.7 g. The mean values for three-dimensional deviation of the center point position for each group of frameworks were 261 µm (cast frameworks before adaptation), 49 µm (cast frameworks after adaptation), 26 µm (milled frameworks in cobalt-chrome), and 26 µm (milled frameworks in titanium). CONCLUSIONS: Within the limitations of this in vitro study, absolute passive fit cannot be achieved, regardless of material and fabrication technique. Anatomic milled frameworks fabricated in titanium or cobalt-chrome presented reduced center point deviation compared to cast frameworks. Titanium frameworks weighed less than cobalt-chrome and cast gold alloy frameworks.


Assuntos
Ligas de Cromo , Desenho Assistido por Computador , Técnica de Fundição Odontológica/normas , Planejamento de Prótese Dentária/normas , Prótese Dentária Fixada por Implante/normas , Mandíbula/anatomia & histologia , Titânio , Implantes Dentários , Planejamento de Prótese Dentária/métodos , Ligas de Ouro , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...