Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Clin Biochem ; 31 ( Pt 5): 501-5, 1994 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-7530440

RESUMO

A comparison of the Roche Cobas Core and Hybritech TANDEM-E PSA (prostate specific antigen) assays revealed a large difference in the reactivity of each assay to the separated free and complexed forms of serum PSA in patients with prostatic carcinoma. The Roche assay was relatively much more responsive to the free form, but the Hybritech assay was relatively more responsive to the complexed form and total serum PSA. It is possible that the adoption of a universal standard for PSA will not completely resolve the disagreement between PSA assay on individual patient samples, and the use of separate assays for the free and complexed forms may be necessary for the further clinical development of PSA as a tumour marker.


Assuntos
Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Biomarcadores Tumorais/sangue , Soluções Tampão , Fracionamento Químico , Cromatografia em Gel , Humanos , Técnicas Imunoenzimáticas , Modelos Lineares , Masculino , Neoplasias da Próstata/diagnóstico , Padrões de Referência , Reprodutibilidade dos Testes , alfa 1-Antiquimotripsina/química
2.
Ann Clin Biochem ; 29 ( Pt 4): 454-60, 1992 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-1642454

RESUMO

We undertook a retrospective analysis of the monthly test rejection rates and the monthly external quality assessment scheme performance indices for our laboratory's two automated analysers, and examined the association of these variables with measures of laboratory workload, manpower, staff training, instrument servicing, seasonal and temporal factors and changes of calibration, method and assigned internal quality control values. Using multiple linear regression and stepwise multiple linear regression, we found that test rejection rates differed significantly between instruments, and were highest on the instrument performing the widest variety and lowest volume of tests. On that instrument, rejection rates were significantly associated with the introduction of new staff and laboratory manpower levels, and also showed a highly significant trend upwards over the study period, independent of the effects of the other variables examined. External quality assessment scheme performance indices showed small trends over the study period. They were not related to the test rejection rates on either analyser but also showed a significant association with the introduction of new staff and a small but significant association with laboratory workload. We conclude that the training and introduction of new staff and decreased laboratory manpower levels may significantly increase the level of test rejection, and adherence to appropriate quality control protocols effectively maintains the quality of the laboratory's results, but may not be completely successful in filtering out the effects of some assignable causes of variation in test results. It is suggested that clinical laboratories use the statistical approach adopted here to identify factors which may be adversely affecting quality performance and running costs and to provide evidence that quality control procedures are both cost- and quality-effective.


Assuntos
Técnicas de Laboratório Clínico/normas , Análise de Regressão , Controle de Qualidade
3.
Biosens Bioelectron ; 6(7): 569-73, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1755999

RESUMO

A catechol enzyme electrode is described, in which a Clark-type oxygen electrode is coupled to immobilised polyphenol oxidase in albumin cross linked with glutaraldehyde on a dialysis membrane. Electrode calibration, response time, pH response profile, stability, detection limit and selectivity are evaluated and the feasibility of using the electrode for the measurement of catecholamines in the urine of patients with neural crest tumours is assessed.


Assuntos
Técnicas Biossensoriais , Catecol Oxidase , Neoplasias do Sistema Nervoso Central/diagnóstico , Enzimas Imobilizadas , Crista Neural , Calibragem , Catecolaminas/urina , Neoplasias do Sistema Nervoso Central/embriologia , Desenho de Equipamento , Humanos , Monitorização Fisiológica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...