Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 27(15): 21092-21101, 2019 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-31510192

RESUMO

We combine diffraction and absorption tomography by raster scanning samples through a hollow cone of pseudo monochromatic X-rays with a mean energy of 58.4 keV. A single image intensifier takes 90x90 (x,y) snapshots during the scan. We demonstrate a proof-of-principle of our technique using a heterogeneous three-dimensional (x,y,z) phantom (90x90x170 mm3) comprised of different material phases, i.e., copper and sodium chlorate. Each snapshot enables the simultaneous measurement of absorption contrast and diffracted flux. The axial resolution was ~1 mm along the (x,y) orthogonal scan directions and ~7 mm along the z-axis. The tomosynthesis of diffracted flux measurements enable the calculation of d-spacing values with ~0.1 Å full width at half maximum (FWHM) at ~2 Å. Thus the identified materials may be color-coded in the absorption optical sections. Characterization of specific material phases is of particular interest in security screening for the identification of narcotics and a wide range of homemade explosives concealed within complex "everyday objects." Other potential application areas include process control and biological imaging.

2.
Opt Express ; 27(14): 19834-19841, 2019 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-31503738

RESUMO

We introduce a new high-energy X-ray diffraction tomography technique for volumetric materials characterization. In this method, a conical shell beam is raster scanned through the samples. A central aperture optically couples the diffracted flux from the samples onto a pixelated energy-resolving detector. Snapshot measurements taken during the scan enable the construction of depth-resolved dark-field section images. The calculation of d-spacing values enables the mapping of material phase in a volumetric image. We demonstrate our technique using five ~15 mm thick, axially separated samples placed within a polymer tray of the type used routinely in airport security stations. Our method has broad analytical utility due to scalability in both scan size and X-ray energy. Additional application areas include medical diagnostics, materials science, and process control.

3.
Opt Express ; 25(18): 21321-21328, 2017 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-29041431

RESUMO

We demonstrate a novel imaging architecture to collect range encoded diffraction patterns from overlapping samples in a single conical shell projection. The patterns were measured in the dark area encompassed by the beam via a centrally positioned aperture optically coupled to a pixelated energy-resolving detector. We show that a single exposure measurement of 0.3 mAs enables d-spacing values to be calculated. The axial positions of the samples were not required and the resultant measurements were robust in the presence of crystallographic textures. Our results demonstrate rapid volumetric materials characterization and the potential for a direct imaging method, which is of great relevance to applications in medicine, non-destructive testing and security screening.

4.
Opt Express ; 24(25): 29048-29059, 2016 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-27958570

RESUMO

We demonstrate depth-resolved absorption imaging by scanning an object through a conical shell of X-rays. We measure ring shaped projections and apply tomosynthesis to extract optical sections at different axial focal plane positions. Three-dimensional objects have been imaged to validate our theoretical treatment. The novel principle of our method is scalable with respect to both scan size and X-ray energy. A driver for this work is to complement previously reported methods concerning the measurement of diffracted X-rays for structural analysis. The prospect of employing conical shell beams to combine both absorption and diffraction modalities would provide enhanced analytical utility and has many potential applications in security screening, process control and diagnostic imaging.

5.
Sci Rep ; 6: 29011, 2016 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-27363947

RESUMO

Osteoporotic fractures present a significant social and economic burden, which is set to rise commensurately with the aging population. Greater understanding of the physicochemical differences between osteoporotic and normal conditions will facilitate the development of diagnostic technologies with increased performance and treatments with increased efficacy. Using coherent X-ray scattering we have evaluated a population of 108 ex vivo human bone samples comprised of non-fracture and fracture groups. Principal component fed linear discriminant analysis was used to develop a classification model to discern each condition resulting in a sensitivity and specificity of 93% and 91%, respectively. Evaluating the coherent X-ray scatter differences from each condition supports the hypothesis that a causal physicochemical change has occurred in the fracture group. This work is a critical step along the path towards developing an in vivo diagnostic tool for fracture risk prediction.


Assuntos
Fraturas por Osteoporose/classificação , Difração de Raios X , Idoso , Idoso de 80 Anos ou mais , Osso e Ossos/fisiopatologia , Análise Discriminante , Feminino , Humanos , Masculino , Fraturas por Osteoporose/diagnóstico por imagem
6.
Phys Med Biol ; 60(15): 5803-12, 2015 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-26159892

RESUMO

There is a compelling need for accurate, low cost diagnostics to identify osteo-tissues that are associated with a high risk of fracture within an individual. To satisfy this requirement the quantification of bone characteristics such as 'bone quality' need to exceed that provided currently by densitometry. Bone mineral chemistry and microstructure can be determined from coherent x-ray scatter signatures of bone specimens. Therefore, if these signatures can be measured, in vivo, to an appropriate accuracy it should be possible by extending terms within a fracture risk model to improve fracture risk prediction.In this preliminary study we present an examination of a new x-ray diffraction technique that employs hollow annular and semi-annular beams to measure aspects of 'bone quality'. We present diffractograms obtained with our approach from ex vivo bone specimens at Mo Kα and W Kα energies. Primary data is parameterized to provide estimates of bone characteristics and to indicate the precision with which these can be determined.


Assuntos
Densidade Óssea/fisiologia , Osso e Ossos/diagnóstico por imagem , Colo do Fêmur/diagnóstico por imagem , Difração de Raios X/instrumentação , Difração de Raios X/métodos , Animais , Calcificação Fisiológica , Bovinos , Densitometria , Radiografia , Raios X
7.
Opt Express ; 23(10): 13443-54, 2015 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-26074592

RESUMO

We demonstrate material phase identification by measuring polychromatic diffraction spots from samples at least 20 mm in diameter and up to 10 mm thick with an energy resolving point detector. Within our method an annular X-ray beam in the form of a conical shell is incident with its symmetry axis normal to an extended polycrystalline sample. The detector is configured to receive diffracted flux transmitted through the sample and is positioned on the symmetry axis of the annular beam. We present the experiment data from a range of different materials and demonstrate the acquisition of useful data with sub-second collection times of 0.5 s; equating to 0.15 mAs. Our technique should be highly relevant in fields that demand rapid analytical methods such as medicine, security screening and non-destructive testing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...