Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Anal Bioanal Chem ; 406(12): 2841-52, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24618988

RESUMO

Enzyme-catalyzed reactions play key roles in disease pathology, thus making them relevant subjects of therapeutic inhibitor screening experiments. Matrix-assisted laser desorption/ionization (MALDI) assays have been demonstrated to be able to replace established screening approaches. They offer increased sample throughput, but care must be taken to avoid instrumental bias from differences in ionization efficiencies. We compared a MALDI-triple-quadrupole (QqQ) method for the Dyrk1A peptide substrate woodtide to LC-MS, liquid chromatography with ultraviolet detection (LC-UV), luminescence, and radiometric assays. MALDI measurements were performed on a MALDI-QqQ instrument in the multiple-reaction monitoring mode. Different MALDI conditions were investigated to address whether matrix type, sample support, and MRM- or SIM-based detection conditions can be used to accommodate the molar responses of substrate peptide and its phosphorylated form. UV detection served as a reference method. The impact of MALDI matrix on IC50 values was small, even considering that matrix preparations were used that are known to alleviate response differences. IC50 values determined by MALDI were ca. 2-fold lower than those determined by LC-UV. Although MALDI generated lower ion yields for the phosphorylated peptide than for the peptide substrate, we found that a correction of compound potencies was readily possible using correction factors based on unbiased LC-UV results. A thorough method development delivered a robust assay with excellent performance (Z' > 0.91) that was close to that seen for LC-UV.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Avaliação Pré-Clínica de Medicamentos/métodos , Inibidores de Proteínas Quinases/química , Proteínas Serina-Treonina Quinases/antagonistas & inibidores , Proteínas Tirosina Quinases/antagonistas & inibidores , Radiometria/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Cromatografia Líquida de Alta Pressão/instrumentação , Humanos , Luminescência , Peptídeos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Quinases Dyrk
2.
Rapid Commun Mass Spectrom ; 27(9): 1011-8, 2013 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-23592204

RESUMO

RATIONALE: Magnetic beads are often used for serum profiling of peptide and protein biomarkers. In these assays, the bead-bound analytes are eluted from the beads prior to mass spectrometric analysis. This study describes a novel matrix-assisted laser desorption/ionization (MALDI) technique for direct application and focusing of magnetic beads to MALDI plates by means of dedicated micro-magnets as sample spots. METHODS: Custom-made MALDI plates with magnetic focusing spots were made using small nickel-coated neodymium micro-magnets integrated into a stainless steel plate in a 16 × 24 (384) pattern. For demonstrating the proof-of-concept, commercial C-18 magnetic beads were used for the extraction of a test compound (reserpine) from aqueous solution. Experiments were conducted to study focusing abilities, the required laser energies, the influence of a matrix compound, dispensing techniques, solvent choice and the amount of magnetic beads. RESULTS: Dispensing the magnetic beads onto the micro-magnet sample spots resulted in immediate and strong binding to the magnetic surface. Light microscope images illustrated the homogeneous distribution of beads across the surfaces of the magnets, when the entire sample volume containing the beads was pipetted onto the surface. Subsequent MALDI analysis of the bead-bound analyte demonstrated excellent and reproducible ionization yields. The surface-assisted laser desorption/ionization (SALDI) properties of the strongly light-absorbing γ-Fe2O3-based beads resulted in similar ionization efficiencies to those obtained from experiments with an additional MALDI matrix compound. CONCLUSIONS: This feasibility study successfully demonstrated the magnetic focusing abilities for magnetic bead-bound analytes on a novel MALDI plate containing small micro-magnets as sample spots. One of the key advantages of this integrated approach is that no elution steps from magnetic beads were required during analyses compared with conventional bead experiments.

3.
Analyst ; 138(5): 1289-315, 2013 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-23314100

RESUMO

Mass spectrometry imaging (MSI) has proven to be extremely useful for applications such as the spatial analysis of peptides and proteins in biological tissue, the performance assessment of drugs in vivo or the measurement of protein or metabolite expression as tissue classifiers or biomarkers from disease versus control tissue comparisons. The most popular MSI technique is MALDI mass spectrometry. First invented by Richard Caprioli in the mid-1990s, it is the highest performing MSI technique in terms of spatial resolution, sensitivity for intact biomolecules and application range today. The unique ability to identify and spatially resolve numerous compounds simultaneously, based on m/z values has inter alia been applied to untargeted and targeted chemical mapping of biological compartments, revealing changes of physiological states, disease pathologies and metabolic faith and distribution of xenobiotics. Many MSI applications focus on lipid species because of the lipids' diverse roles as structural components of cell membranes, their function in the surfactant cycle, and their involvement as second messengers in signalling cascades of tissues and cells. This article gives a comprehensive overview of lipid imaging techniques and applications using established MALDI and SIMS methods but also other promising MSI techniques such as DESI.


Assuntos
Lipídeos/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Espectrometria de Massa de Íon Secundário/métodos , Animais , Desenho de Equipamento , Humanos , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Espectrometria de Massa de Íon Secundário/instrumentação
4.
Anal Bioanal Chem ; 404(2): 433-45, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22669308

RESUMO

Determination of trace constituents in biological and environmental samples usually requires a pre-concentration step. While solid-phase extraction (SPE) has been widely used, it is slow, labor intensive and adversely affected by analytical errors from handling. On-line SPE eliminates some of the flaws but often suffers from solvent compatibility problems with the subsequent chromatography separation. In this study, we are presenting a technical solution for overcoming some of these compatibility issues, by utilizing a fully automated, focused SPE sample transfer technique utilizing narrow-band solvent plugs, for seamless hyphenation with high-performance liquid chromatography (HPLC) or flow injection mass spectrometry (MS). A wide range of pharmaceutical compounds was studied in different sample matrices. Short plugs of high elution strength solvent were generated by means of an electrically actuated sample loop and enrichment and transfer steps monitored using on-line SPE-MS. The impact of the solvent plugs on chromatographic separation was studied using hyphenated SPE-LC-MS. By carefully examining elution profiles of solvent plugs of different compositions, optimum conditions for quantitative elution within well-defined volumes were found for all substances. In addition, the highly focused elution bands resulted in excellent retention time and peak area reproducibilities when injected on-line onto HPLC columns. Finally, to demonstrate proof-of-principle, the fully integrated on-line SPE-LC-MS system was applied to the analysis of spiked urine and river water samples.


Assuntos
Extração em Fase Sólida , Solventes/química , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...