Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Eur Cell Mater ; 31: 250-63, 2016 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-27071735

RESUMO

We explored the osseointegration potential of two macroporous titanium surfaces obtained using fast plasma sintering (FPS): Ti macroporous structures with 400-600 µmØ pores (TiMac400) and 850-1000 µmØ pores (TiMac850). They were compared against two surfaces currently in clinical use: Ti-Growth® and air plasma spray (Ti-Y367). Each surface was tested, once placed over a Ti-alloy and once onto a CoCr bulk substrate. Implants were placed in medial femoral condyles in 24 sheep. Samples were explanted at four and eight weeks after surgery. Push-out loads were measured using a material-testing system. Bone contact and ingrowth were assessed by histomorphometry and SEM and EDX analyses. Histology showed early osseointegration for all the surfaces tested. At 8 weeks, TiMac400, TiMac850 and Ti-Growth® showed deep bone ingrowth and extended colonisation with newly formed bone. The mechanical push-out force was equal in all tested surfaces. Plasma spray surfaces showed greater bone-implant contact and higher level of pores colonisation with new bone than FPS produced surfaces. However, the void pore area in FPS specimens was significantly higher, yet the FPS porous surfaces allowed a deeper osseointegration of bone to implant. FPS manufactured specimens showed similar osseointegration potential to the plasma spray surfaces for orthopaedic implants. FPS is a useful technology for manufacturing macroporous titanium surfaces. Furthermore, its capability to combine two implantable materials, using bulk CoCr with macroporous titanium surfaces, could be of interest as it enables designers to conceive and manufacture innovative components. FPS delivers functional graded materials components with macroporous structures optimised for osseointegration.


Assuntos
Materiais Biocompatíveis/farmacologia , Desenvolvimento Ósseo/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/farmacologia , Teste de Materiais/métodos , Osseointegração/fisiologia , Próteses e Implantes , Titânio/farmacologia , Animais , Microscopia Eletrônica de Varredura , Osseointegração/efeitos dos fármacos , Porosidade , Ovinos , Espectrometria por Raios X , Propriedades de Superfície , Titânio/metabolismo
2.
Arq. bras. med. vet. zootec ; 63(1): 20-27, Feb. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-582319

RESUMO

Foram examinados, por meio de eletrocardiografia, 14 equinos Puro Sangue Árabe, 12 machos e duas fêmeas, desclassificados por exaustão em provas de enduro entre 60 e 160km. Foi observado predomínio de taquicardia sinusal, seguido de arritmia sinusal e complexo atrial prematuro com a frequência cardíaca variando de 48 a 78bpm e 93 a 111bpm, respectivamente. Ocorreu aumento da amplitude das ondas P, R, S e T e redução nas suas durações, bem como redução nos intervalos e segmentos, porém o complexo QRS quase não se alterou. O alongamento observado do QTc indicou fadiga miocárdica moderada em resposta ao exercício, e o supradesnível ST foi indicativo de hipovolemia. O eixo elétrico no plano frontal apresentou desvio à direita, aumento de câmara e hipertrofia secundários ao treinamento.


By using electrocardiographic examination, 14 Purebred Arabian horses, 12 males and two females, disqualified due to exhaustion in endurance races from 60 and 160km were evaluated. Predominance of sinus tachycardia, followed by sinus arrhythmia and atrial premature complex, with the heart rate ranging from 48 to 78bpm, and 93 to 111bpm, respectively, were observed. There was increase in the amplitude of waves P, R, S, and T, and decrease in their durations, as well as reduction in the intervals and segments; nevertheless, the QRS complex was not almost altered. The QTc lengthening pointed to a moderate myocardial fatigue in response to exercise, and the elevation of ST was indicative of hypovolemia. The electrical axis in frontal plane presented deviation to the right, chamber increase, and hypertrophy secondary to training.


Assuntos
Animais , Cavalos/classificação , Eletrocardiografia , Esgotamento Profissional , Fadiga/complicações , Hipertrofia/patologia
3.
Arq. bras. med. vet. zootec ; 59(6): 1376-1381, dez. 2007. tab
Artigo em Português | LILACS | ID: lil-476104

RESUMO

Colheram-se amostras de sangue do cordão umbilical (SCU) e do sangue circulante de cinco eqüinos neonatos, imediatamente após o nascimento, e o sangue da própria mãe, utilizando-se um sistema a vácuo. O material foi submetido à contagem global de hemácias e leucócitos e à determinação do volume globular e da concentração de hemoglobina; à contagem diferencial de leucócitos em esfregaços sangüíneos; e ao cálculo dos índices eritrocitométricos. Foram realizadas a dosagem de proteínas séricas totais e a eletroforese das proteínas séricas em gel de agarose. Não houve diferenças significativas entre os parâmetros do SCU e do sangue da jugular dos potros. No SCU dos potros observaram-se valores mais elevados para contagem global de hemácias (9,75x10(6)/µl), dosagem de hemoglobina (14,65g/dl) e concentração de hemoglobina corpuscular média (37,23g/dl); e valores menores para volume corpuscular médio (40,50fl), proteína total (4,37g/dl), alfa-globulinas (0,65g/dl), beta-globulinas (1,10g/dl), gama-globulinas (0g/dl) e contagens global (5,40 x 10³/µl) e diferencial de leucócitos, exceto contagem de neutrófilos bastonetes e monócitos, quando comparados com os valores obtidos no sangue de suas mães


Umbilical cord blood (UCB) and systemic blood samples were collected from five equine neonates, immediately after birth. Systemic blood samples from their mothers were also collected at the same time, using a vacuum system. The samples were submitted to the following analyses: red blood cell and total white blood cell counts; determinations of packed cell volume and hemoglobin concentration; differential white cell count in blood smears; and determination of erythrocytometric values. Total serum proteins quantification and serum proteins electrophoresis in agarose gel were done. No significant difference (P<0.05) was noted between averages in neonate jugular blood and equine UCB. Equine UCB showed higher values of red blood cell count (9.75x10(6)/µ), hemoglobin determination (14.65g/dl), and mean corpuscular hemoglobin concentration (37.23g/dl); but lower values of mean corpuscular volume (40.50fl), total protein (4.37g/dl), alpha-globulin (0.65 g/dl), beta-globulin (1.10g/dl), gamma-globulin (0g/dl), total (5.40x10³/µl), and differential leukocytes count, except for band neutrophils and monocytes counts, when compared to the blood of the mares


Assuntos
Animais , Recém-Nascido , Adulto , Contagem de Células Sanguíneas/veterinária , Sangue Fetal , Cavalos , Proteínas Sanguíneas/análise , Análise Química do Sangue/veterinária , Eletroforese das Proteínas Sanguíneas/veterinária
4.
Arq. bras. med. vet. zootec ; 58(1): 44-51, fev. 2006. ilus, tab
Artigo em Português | LILACS | ID: lil-430791

RESUMO

Foram comparadas duas técnicas de neurorrafia em seis eqüinos, divididos em três grupos (G), conforme o tempo para a biópsia. Os animais foram submetidos a neurectomia dos nervos digitais palmares (NDP) e aplicaram-se duas suturas epineurais (SE) e suturas com tubos de silicone (STS) em cada animal. Avaliaram-se os animais mensalmente pelo teste de sensibilidade e exame do aparelho locomotor até a realização das biópsias dos NDP. Aos 30 dias pós-cirurgia foi realizada biópsia no GI, aos 60 dias no GII e aos 180 dias no GIII. Macroscopicamente, o NDP encontrou-se envolvido por tecido conjuntivo fibroso. Microscopicamente, constataram-se proliferação axonal em uma amostra do GI e neuromas nas amostras dos GI, GII e GIII. Houve proliferação de tecido conjuntivo em todos os grupos no local de reparação para SE e adentrando no interior do tubo na STS. Visibilizaram-se infiltrado de células inflamatórias, alterações no coto proximal e degeneração no coto distal na SE e na STS. As técnicas não apresentaram resultados satisfatórios quanto ao grau de regeneração do coto proximal até o coto distal.


Two neurorrhaphy techniques were compared using six horses divided in three groups (G), based on the biopsy time. After neurectomy of the palmar digital nerves (DPN), two epineural sutures (ES) and two sutures with silicone tube (STS) were applied in each animal. All animals were evaluated monthly by sensitivity test and locomotor apparatus examination until collection of the suture sites by biopsy. Biopsy procedure was performed at 30 days post surgery in G1, 60 days in G2 and 180 days in G3. Grossly, the digital palmar nerve was involved by fibrous connective tissue. Microscopically, axonal growth in one sample from G1 and neuroma in samples from G1, G2 and G3 were observed. Proliferation of connective tissue occurred in all groups in repaired areas of ES and penetrated in the interior of STS tubes. Inflammatory cells, alterations of the proximal stump and degeneration of distal stump in ES and in STS were observed. Both techniques showed no satisfactory results regarding the degree of regeneration from proximal to distal stump.


Assuntos
Animais , Cirurgia Veterinária/métodos , Cavalos , Regeneração Nervosa , Técnicas de Sutura/reabilitação , Técnicas de Sutura/veterinária
5.
Arq. bras. med. vet. zootec ; 57(3): 288-294, jun. 2005. tab
Artigo em Português | LILACS | ID: lil-415143

RESUMO

Foram estudadas as características físico-químicas e citológicas do líquido sinovial da bainha tendínea digital de nove eqüinos hígidos. Verificou-se que o líquido é viscoso, amarelo claro, límpido, livre de partículas e que não coagula à temperatura ambiente. Sua concentração média de ácido hialurônico foi 60,20mg/dl, a taxa de glicose, similar à plasmática e sua concentração protéica não ultrapassou 1,74g/dl, com relação média albumina:globulina de 0,94. O número médio de células nucleadas foi de 313 células/æl, com predominância de grandes células mononucleares e linfócitos. Houve correlação significativa (r = - 0,649, P<0,01) entre o aumento da concentração de ácido hialurônico e a diminuição percentual de linfócitos. As mensurações das características pesquisadas no líquido sinovial da bainha tendínea digital de eqüinos são de execução simples e passíveis de implantação na rotina de atendimentos clínico-cirúrgicos.


Assuntos
Animais , Masculino , Equidae , Líquido Sinovial/citologia , Líquido Sinovial/química , Tenossinovite/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...