Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
J Clin Monit Comput ; 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381359

RESUMO

Haemodynamic monitoring and management are cornerstones of perioperative care. The goal of haemodynamic management is to maintain organ function by ensuring adequate perfusion pressure, blood flow, and oxygen delivery. We here present guidelines on "Intraoperative haemodynamic monitoring and management of adults having non-cardiac surgery" that were prepared by 18 experts on behalf of the German Society of Anaesthesiology and Intensive Care Medicine (Deutsche Gesellschaft für Anästhesiologie und lntensivmedizin; DGAI).

2.
Front Cardiovasc Med ; 9: 900850, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35845063

RESUMO

Purpose: We aimed to investigate whether left ventricular diastolic dysfunction (LVDD) is associated with pulmonary edema in septic patients. Methods: We conducted a prospective cohort study in adult septic patients between October 2018 and May 2019. We performed repeated echocardiography and lung ultrasound examinations within the first 7 days after diagnosis of sepsis. We defined LVDD according to the 2016 recommendations of the American Society of Echocardiography and-for sensitivity analysis-according to an algorithm which has been validated in septic patients. We quantified pulmonary edema using the lung ultrasound score (LUSS), counting B-lines in four intercostal spaces. Results: We included 54 patients. LVDD was present in 51 (42%) of 122 echocardiography examinations. The mean (±SD) LUSS was 11 ± 6. There was no clinically meaningful association of LVDD with LUSS (B = 0.55 [95%CI: -1.38; 2.47]; p = 0.571). Pneumonia was significantly associated with higher LUSS (B = 4.42 [95%CI: 0.38; 8.5]; p = 0.033). Conclusion: The lack of a clinically meaningful association of LVDD with LUSS suggests that LVDD is not a major contributor to pulmonary edema in septic patients. Trial Registration: NCT03768752, ClinicalTrials.gov, November 30th, 2018 - retrospectively registered.

3.
Anesth Analg ; 132(2): 420-429, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33264119

RESUMO

BACKGROUND: Diastolic dysfunction is a risk factor for postoperative major cardiovascular events. During anesthesia, patients with diastolic dysfunction might experience impaired hemodynamic function and worsening of diastolic function, which in turn, might be associated with a higher incidence of postoperative complications.We aimed to investigate whether patients with diastolic dysfunction require higher doses of norepinephrine during general anesthesia. Furthermore, we aimed to examine the association between the grade of diastolic dysfunction and the E/e' ratio during anesthesia. A high E/e' ratio corresponds to elevated filling pressures and is an important measure of impaired diastolic function. METHODS: We conducted a prospective observational cohort study at a German university hospital from February 2017 to September 2018. Patients aged ≥60 years and undergoing general anesthesia (ie, propofol and sevoflurane) for elective noncardiac surgery were enrolled. Exclusion: mitral valve disease, atrial fibrillation, and implanted mechanical device.The primary outcome parameter was the administered dose of norepinephrine within 30 minutes after anesthesia induction (µg·kg-1 30 min-1). The secondary outcome parameter was the change of Doppler echocardiographic E/e' from ECHO1 (baseline) to ECHO2 (anesthesia). Linear models and linear mixed models were used for statistical evaluation. RESULTS: A total of 247 patients were enrolled, and 200 patients (75 female) were included in the final analysis. Diastolic dysfunction at baseline was not associated with a higher dose of norepinephrine during anesthesia (P = .6953). The grade of diastolic dysfunction at baseline was associated with a decrease of the E/e' ratio during anesthesia (P < .001). CONCLUSIONS: We did not find evidence for an association between diastolic dysfunction and impaired hemodynamic function, as expressed by high vasopressor support during anesthesia. Additionally, our findings suggest that diastolic function, as expressed by the E/e' ratio, does not worsen during anesthesia.


Assuntos
Agonistas alfa-Adrenérgicos/administração & dosagem , Anestesia Geral , Norepinefrina/administração & dosagem , Procedimentos Cirúrgicos Operatórios , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral/efeitos adversos , Diástole , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem
4.
Minerva Anestesiol ; 85(3): 263-270, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-29945434

RESUMO

BACKGROUND: In patients with hemodynamic instability echocardiography has been recommended as the preferred modality to evaluate the underlying pathophysiology. However, due to the fact that recent scientific data on the utilization of echocardiography in German Intensive Care Units (ICU) are scarce, we sought to investigate current practice. METHODS: A structured, web-based, anonymized survey was performed from May until July 2015 among members of the German Interdisciplinary Association of Critical Care and Emergency Medicine (DIVI) consisting of 14 questions. Descriptive data analysis was performed. RESULTS: One hundred four intensivists participated in the survey. Two-thirds of participants (66%) used echocardiography regularly for hemodynamic monitoring and stated that it changed the therapy in 26-50% of the cases irrespective of the time performed after ordering the examination. Transthoracic (TTE) were more frequently used than transesophageal (TEE) examinations. Twenty-six percent of the participants held an echocardiography certificate with a formal examination, 27% completed a structured training without an examination and almost half of the questioned ICU personnel (47%) did not complete a comprehensive training. CONCLUSIONS: The results of this survey demonstrate a widespread utilization of echocardiography as part of routine diagnostic on frequent number of operative ICUs. However, there might be a lack of structured echocardiographic training especially for anesthesiologists.


Assuntos
Cuidados Críticos , Ecocardiografia/estatística & dados numéricos , Medicina de Emergência , Padrões de Prática Médica , Utilização de Procedimentos e Técnicas/estatística & dados numéricos , Cuidados Críticos/métodos , Alemanha , Pesquisas sobre Atenção à Saúde , Humanos , Unidades de Terapia Intensiva , Internet
5.
PLoS One ; 12(10): e0186481, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29049339

RESUMO

BACKGROUND: Monitoring cardiac output (CO) is important to optimize hemodynamic function in critically ill patients. The prevalence of aortic valve insufficiency (AI) is rising in the aging population. However, reliability of CO monitoring techniques in AI is unknown. The aim of this study was to investigate the impact of AI on accuracy, precision, and trending ability of transcardiopulmonary thermodilution-derived COTCPTD in comparison with pulmonary artery catheter thermodilution COPAC. METHODS: Sixteen anesthetized domestic pigs were subjected to serial simultaneous measurements of COPAC and COTCPTD. In a novel experimental model, AI was induced by retraction of an expanded Dormia basket in the aortic valve annulus. The Dormia basket was delivered via a Judkins catheter guided by substernal epicardial echocardiography. High (HPC), moderate (MPC) and low cardiac preload conditions (LPC) were induced by fluid unloading (20 ml kg-1 blood withdrawal) and loading (subsequent retransfusion of the shed blood and additional infusion of 20 ml kg-1 hydroxyethyl starch). Within each preload condition CO was measured before and after the onset of AI. For statistical analysis, we used a mixed model analysis of variance, Bland-Altman analysis, the percentage error and concordance analysis. RESULTS: Experimental AI had a mean regurgitant volume of 33.6 ± 12.0 ml and regurgitant fraction of 42.9 ± 12.6%. The percentage error between COTCPTD and COPAC during competent valve function and after induction of substantial AI was: HPC 17.7% vs. 20.0%, MPC 20.5% vs. 26.1%, LPC 26.5% vs. 28.1% (pooled data: 22.5% vs. 24.1%). The ability to trend CO-changes induced by fluid loading and unloading did not differ between baseline and AI (concordance rate 95.8% during both conditions). CONCLUSION: Despite substantial AI, transcardiopulmonary thermodilution reliably measured CO under various cardiac preload conditions with a good ability to trend CO changes in a porcine model. COTCPTD and COPAC were interchangeable in substantial AI.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Débito Cardíaco , Termodiluição/métodos , Animais , Reprodutibilidade dos Testes , Suínos
7.
J Clin Monit Comput ; 31(1): 213-219, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26621389

RESUMO

The problem of high rates of false alarms in patient monitoring in anesthesiology and intensive care medicine is well known but remains unsolved. False alarms desensitize the medical staff, leading to ignored true alarms and reduced quality of patient care. A database of intra-operative monitoring data was analyzed to find characteristic alarm patterns. The original data were re-evaluated to find relevant events and to rate the severity of these events. Based on this analysis an adaptive time delay was developed that individually delays the alarms depending on the grade of threshold deviation. The conventional threshold algorithm led to 4893 alarms. 3515 (71.84 %) of these alarms were annotated as clinically irrelevant. In total 81.0 % of all clinically irrelevant alarms were caused by only mild and/or brief threshold violations. We implemented the new algorithm for selected parameters. These parameters equipped with adaptive validation delays led to 1729 alarms. 931 (53.85 %) alarms were annotated as clinically irrelevant. 632 alarms indicated the 645 clinically relevant events. The positive predictive value of occurring alarms improved from 28.16 % (conventional algorithm) to 46.15 % (new algorithm). 13 events were missed. The false positive alarm reduction rate of the algorithm ranged from 33 to 86.75 %. The overall reduction was 73.51 %. The implementation of this algorithm may be able to suppress a large percentage of false alarms. The effect of this approach has not been demonstrated but shows promise for reducing alarm fatigue. Its safety needs to be proven in a prospective study.


Assuntos
Alarmes Clínicos , Fadiga Mental/prevenção & controle , Monitorização Intraoperatória/métodos , Monitorização Fisiológica/métodos , Algoritmos , Anestesiologia/métodos , Cuidados Críticos , Bases de Dados Factuais , Humanos , Unidades de Terapia Intensiva , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo
8.
Ann Intensive Care ; 6(1): 49, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27246463

RESUMO

BACKGROUND: Hemodynamic instability is frequent and outcome-relevant in critical illness. The understanding of complex hemodynamic disturbances and their monitoring and management plays an important role in treatment of intensive care patients. An increasing number of treatment recommendations and guidelines in intensive care medicine emphasize hemodynamic goals, which go beyond the measurement of blood pressures. Yet, it is not known to which extent the infrastructural prerequisites for extended hemodynamic monitoring are given in intensive care units (ICUs) and how hemodynamic management is performed in clinical practice. Further, it is still unclear which factors trigger the use of extended hemodynamic monitoring. METHODS: In this multicenter, 1-day (November 7, 2013, and the preceding 24 h) cross-sectional study, we retrieved data on patient monitoring from ICUs in Germany, Austria, and Switzerland by means of a web-based case report form. One hundred and sixty-one intensive care units contributed detailed information on availability of hemodynamic monitoring. In addition, detailed information on hemodynamic monitoring of 1789 patients that were treated on due date was collected, and independent factors triggering the use of extended hemodynamic monitoring were identified by multivariate analysis. RESULTS: Besides basic monitoring with electrocardiography (ECG), pulse oximetry, and blood pressure monitoring, the majority of patients received invasive arterial (77.9 %) and central venous catheterization (55.2 %). All over, additional extended hemodynamic monitoring for assessment of cardiac output was only performed in 12.3 % of patients, while echocardiographic examination was used in only 1.9 %. The strongest independent predictors for the use of extended hemodynamic monitoring of any kind were mechanical ventilation, the need for catecholamine therapy, and treatment backed by protocols. In 71.6 % of patients in whom extended hemodynamic monitoring was added during the study period, this extension led to changes in treatment. CONCLUSIONS: Extended hemodynamic monitoring, which goes beyond the measurement of blood pressures, to date plays a minor role in the surveillance of critically ill patients in German, Austrian, and Swiss ICUs. This includes also consensus-based recommended diagnostic and monitoring applications, such as echocardiography and cardiac output monitoring. Mechanical ventilation, the use of catecholamines, and treatment backed by protocol could be identified as factors independently associated with higher use of extended hemodynamic monitoring.

10.
PLoS One ; 10(8): e0134097, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26312484

RESUMO

BACKGROUND: Anesthetic administration is increasingly guided by electroencephalography (EEG)-based monitoring, such as the bispectral index (BIS). However, during cardiopulmonary bypass (CPB), factors other than the administered hypnotic agents may influence EEG signals, and their effects on BIS values are unknown. METHODS: This report is a secondary analysis of data from a prospective, controlled interventional study comparing the effect of sevoflurane administration guided by BIS monitoring (group SevoBIS) and constant administration of sevoflurane (group Sevo1.8Vol%) during CPB. Sevoflurane plasma concentration (SPC) was measured using gas chromatography. The relationships of BIS to SPC, CPB pump flow, arterial pressure, hematocrit, temperature, time on CPB, and patient characteristics were analysed. RESULTS: No association was observed between BIS values and SPC in group SevoBIS. In group Sevo1.8Vol%, a 40 µg ml-1 increase in SPC, which encompassed the entire range of observed values of the SPC in this analysis, was associated with a decrease of 3.6 (95% confidence interval (CI): 1.1-6.1) in BIS values (p = 0.005). Each increase in CPB time of 10 minutes was associated with an increase in BIS values of 0.25 (95%CI: 0.11-0.39, p<0.001). Path analysis revealed that the BIS values of SevoBIS patients were 5.3 (95%CI: 3.2-7.5) units higher than those of Sevo1.8Vol% patients (p<0.001), which was the strongest effect on BIS values. Path analysis revealed a slope of 0.5 (95%CI: 0.3-0.7) BIS units per 1°C body temperature (p<0.001). CONCLUSION: BIS monitoring is insensitive to clinically relevant changes in SPC in individual patients during CPB.


Assuntos
Anestesia/métodos , Anestésicos Inalatórios/sangue , Ponte Cardiopulmonar , Monitores de Consciência , Eletroencefalografia , Éteres Metílicos/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestésicos Inalatórios/farmacologia , Anestésicos Inalatórios/uso terapêutico , Pressão Arterial , Temperatura Corporal , Cromatografia Gasosa , Feminino , Hematócrito , Humanos , Masculino , Éteres Metílicos/farmacologia , Éteres Metílicos/uso terapêutico , Pessoa de Meia-Idade , Sevoflurano , Fatores de Tempo
11.
J Clin Monit Comput ; 29(3): 323-31, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25355556

RESUMO

This prospective single-center study aimed to determine the responsiveness and diagnostic performance of continuous cardiac output (CCO) monitors based on pulse contour analysis compared with invasive mean arterial pressure (MAP) during predefined periods of acute circulatory deterioration in patients undergoing transcatheter aortic valve implantation (TAVI). The ability of calibrated (CCO(CAL)) and self-calibrated (CCO(AUTOCAL)) pulse contour analysis to detect the hemodynamic response to 37 episodes of balloon aortic valvuloplasty enabled by rapid ventricular pacing was quantified in 13 patients undergoing TAVI. A "low" and a "high" cut-off limit were predefined as a 15 or 25 % decrease from baseline respectively. We found no significant differences between CCO(CAL) and MAP regarding mean response time [low cut-off: 8.6 (7.1-10.5) vs. 8.9 (7.3-10.8) s, p = 0.76; high cut-off: 11.4 (9.7-13.5) vs. 12.6 (10.7-14.9) s, p = 0.32] or diagnostic performance [area under the receiver operating characteristics curve (AUC): 0.99 (0.98-1.0) vs. 1.0 (0.99-1.0), p = 0.46]. But CCOCAL had a significantly higher amplitude response [95.0 (88.7-98.8) % decrease from baseline] than MAP [41.2 (30.0-52.9) %, p < 0.001]. CCOAUTOCAL had a significantly lower AUC [0.83 (0.73-0.93), p < 0.001] than MAP. Moreover, CCO(CAL) detected hemodynamic recovery significantly earlier than MAP. In conclusion, CCO(CAL) and MAP provided equivalent responsiveness and diagnostic performance to detect acute circulatory depression, whereas CCO(AUTOCAL) appeared to be less appropriate. In contrast to CCO(CAL) the amplitude response of MAP was poor. Consequently even small response amplitudes of MAP could indicate severe decreases in CO.


Assuntos
Débito Cardíaco/fisiologia , Monitorização Fisiológica/métodos , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Área Sob a Curva , Valvuloplastia com Balão , Calibragem , Sistemas Computacionais , Feminino , Frequência Cardíaca , Hemodinâmica , Humanos , Masculino , Estudos Prospectivos , Curva ROC , Processamento de Sinais Assistido por Computador , Termodiluição , Resultado do Tratamento
12.
J Cardiothorac Vasc Anesth ; 28(5): 1273-7, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25281044

RESUMO

OBJECTIVE: In critical illness, hypoglycemia and hyperglycemia seem to influence outcome. While hypoglycemia can lead to organ dysfunction, hyperglycemia can lead to surgical site infections (SSI). In cardiac surgery, the use of blood cardioplegia is associated with high blood glucose levels. A computer-based algorithm (CBA) for guiding insulin towards normoglycemia might be beneficial. The authors' primary study end-point was the duration in a predefined blood glucose target range of 80 mg/dL to 150 mg/dL. Patients with conventional therapy served as controls. DESIGN: Prospective, randomized trial. SETTING: University hospital. PARTICIPANTS: Seventy-five patients. INTERVENTIONS: The start of therapy was the beginning of cardiopulmonary bypass. Group A: Therapy with CBA and measurement of blood glucose every 30 minutes. Group B: Measurement of blood glucose every 15 minutes using the identical CBA. Group C: Conventional therapy using a fixed insulin dosing scheme. End of therapy was defined as discharge from ICU. MEASUREMENT AND MAIN RESULTS: Glucose administration during cardioplegia did not differ between groups (A: 33 ± 12 g; B: 32 ± 12 g; C: 38 ± 20 g). Glucose levels in groups A and B stayed significantly longer in the target interval compared with group C (A: 75 ± 20%; B: 72 ± 19%; C: 50 ± 34%, p < 0.01 n = 25, respectively). There were no significant differences regarding ICU stay and SSI rates. CONCLUSIONS: Early computer-based insulin therapy allows practitioners to better achieve normoglycemia in patients undergoing major cardiac surgery with the use of blood cardioplegia.


Assuntos
Algoritmos , Ponte Cardiopulmonar/métodos , Simulação por Computador , Índice Glicêmico/fisiologia , Parada Cardíaca Induzida/métodos , Assistência Perioperatória/métodos , Idoso , Idoso de 80 Anos ou mais , Glicemia/metabolismo , Ponte Cardiopulmonar/normas , Estudos de Viabilidade , Feminino , Parada Cardíaca Induzida/normas , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória/normas , Estudos Prospectivos
13.
Eur J Anaesthesiol ; 31(9): 482-90, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24927118

RESUMO

BACKGROUND: Electroencephalographic-based monitoring systems such as the bispectral index (BIS) may reduce anaesthetic overdose rates. OBJECTIVE: We hypothesised that goal-directed sevoflurane administration (guided by BIS monitoring) could reduce the sevoflurane plasma concentration (SPC) and intraoperative vasopressor doses during on-pump cardiac surgery. DESIGN: A prospective, controlled, sequential two-arm clinical study. SETTING: German university medical centre with more than 2500 cardiac surgery interventions per year. PATIENTS: Sixty elective on-pump cardiac surgery patients. INTERVENTION: In group Sevo1.8% (n = 29), the sedation depth was maintained with a sustained inspired concentration of sevoflurane 1.8% before and during cardiopulmonary bypass (CPB). In group SevoBIS (n = 31), the inspired sevoflurane concentration was titrated to maintain a BIS target between 40 and 60. OUTCOME MEASURES: SPC during CPB and the intraoperative administration of noradrenaline. Additional analyses were performed on intraoperative awareness, postoperative blood lactate concentration, duration of mechanical ventilation, intensive care unit length of stay and kidney injury. RESULTS: Mean inspired sevoflurane concentration was 0.8% in group SevoBIS, representing a 57.1% reduction (P < 0.001) compared with group Sevo1.8%. The mean SPC was 42.3 µg ml(-1) [95% confidence interval (CI) 40.0 to 44.6] in group Sevo1.8% and 21.0 µg ml(-1) (95% CI 18.8 to 23.3) in group SevoBIS, representing a 50.2% reduction (P < 0.001). During CPB, the mean cumulative dose of noradrenaline administered was 13.48 µg kg(-1) (95% CI 10.52 to 17.19) in group Sevo1.8% and 4.06 µg kg(-1) (95% CI 2.67 to 5.97) in group SevoBIS (P < 0.001). Pearson's correlation coefficient (between the cumulative applied dosage of sevoflurane calculated from the area under the curve of the SPC over time and the administered cumulative noradrenaline dose) was 0.607 (P < 0.001). No intraoperative awareness signs were detected. CONCLUSION: BIS-guided titration of sevoflurane reduces the SPC and decreases noradrenaline administration compared with routine care during on-pump cardiac surgery.


Assuntos
Anestésicos Inalatórios/administração & dosagem , Ponte de Artéria Coronária/métodos , Éteres Metílicos/administração & dosagem , Norepinefrina/administração & dosagem , Centros Médicos Acadêmicos , Idoso , Anestésicos Inalatórios/farmacocinética , Monitores de Consciência , Relação Dose-Resposta a Droga , Eletroencefalografia/métodos , Feminino , Seguimentos , Alemanha , Humanos , Masculino , Éteres Metílicos/farmacocinética , Pessoa de Meia-Idade , Estudos Prospectivos , Sevoflurano , Vasoconstritores/administração & dosagem
15.
Anesthesiology ; 119(4): 824-36, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23732173

RESUMO

BACKGROUND: The authors hypothesized that goal-directed hemodynamic therapy, based on the combination of functional and volumetric hemodynamic parameters, improves outcome in patients with cardiac surgery. Therefore, a therapy guided by stroke volume variation, individually optimized global end-diastolic volume index, cardiac index, and mean arterial pressure was compared with an algorithm based on mean arterial pressure and central venous pressure. METHODS: This prospective, controlled, parallel-arm, open-label trial randomized 100 coronary artery bypass grafting and/or aortic valve replacement patients to a study group (SG; n = 50) or a control group (CG; n = 50). In the SG, hemodynamic therapy was guided by stroke volume variation, optimized global end-diastolic volume index, mean arterial pressure, and cardiac index. Optimized global end-diastolic volume index was defined before and after weaning from cardiopulmonary bypass and at intensive care unit (ICU) admission. Mean arterial pressure and central venous pressure served as hemodynamic goals in the CG. Therapy was started immediately after induction of anesthesia and continued until ICU discharge criteria, serving as primary outcome parameter, were fulfilled. RESULTS: Intraoperative need for norepinephrine was decreased in the SG with a mean (±SD) of 9.0 ± 7.6 versus 14.9 ± 11.1 µg/kg (P = 0.002). Postoperative complications (SG, 40 vs. CG, 63; P = 0.004), time to reach ICU discharge criteria (SG, 15 ± 6 h; CG, 24 ± 29 h; P < 0.001), and length of ICU stay (SG, 42 ± 19 h; CG, 62 ± 58 h; P = 0.018) were reduced in the SG. CONCLUSION: Early goal-directed hemodynamic therapy based on cardiac index, stroke volume variation, and optimized global end-diastolic volume index reduces complications and length of ICU stay after cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Hemodinâmica/fisiologia , Unidades de Terapia Intensiva/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Complicações Pós-Operatórias/prevenção & controle , Agonistas alfa-Adrenérgicos/uso terapêutico , Idoso , Valva Aórtica/cirurgia , Pressão Arterial/efeitos dos fármacos , Pressão Arterial/fisiologia , Pressão Venosa Central/efeitos dos fármacos , Pressão Venosa Central/fisiologia , Ponte de Artéria Coronária/métodos , Diástole/efeitos dos fármacos , Diástole/fisiologia , Epinefrina/uso terapêutico , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Derivados de Hidroxietil Amido/uso terapêutico , Soluções Isotônicas/uso terapêutico , Masculino , Substitutos do Plasma/uso terapêutico , Estudos Prospectivos , Solução de Ringer , Volume Sistólico/efeitos dos fármacos , Volume Sistólico/fisiologia
16.
Anesth Analg ; 117(1): 83-90, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23592603

RESUMO

BACKGROUND: The thermodilution curve assessed by transpulmonary thermodilution is the basis for calculation of global end-diastolic volume index (GEDI) and extravascular lung water index (EVLWI). Until now, it was unclear whether the method is affected by 1-lung ventilation. Therefore, aim of our study was to evaluate the impact of 1-lung ventilation on the thermodilution curve and assessment of GEDI and EVLWI. METHODS: In 23 pigs, mean transit time, down slope time, and difference in blood temperature (ΔTb) were assessed by transpulmonary thermodilution. "Gold standard" cardiac output was measured by pulmonary artery flowprobe (PAFP) and used for GEDIPAFP and EVLWIPAFP calculations. Measurements were performed during normovolemia during double-lung ventilation (M1), 15 minutes after 1-lung ventilation (M2) and during hypovolemia (blood withdrawal 20 mL/kg) during double-lung ventilation (M3) and again 15 minutes after 1-lung ventilation (M4). RESULTS: Configuration of the thermodilution curve was significantly affected by 1-lung ventilation demonstrated by an increase in ΔTb and a decrease in mean transit time and down slope time (all P < 0.04) during normovolemia and hypovolemia. GEDIPAFP was lower after 1-lung ventilation during normovolemia (M1: 459.9 ± 67.5 mL/m(2); M2: 397.0 ± 54.8 mL/m(2); P = 0.001) and hypovolemia (M3: 300.6 ± 40.9 mL/m(2); M4: 275.2 ± 37.6 mL/m(2); P = 0.03). EVLWIPAFP also decreased after 1-lung ventilation in normovolemia (M1: 9.0 [7.3, 10.1] mL/kg; M2: 7.4 [5.8, 8.3] mL/kg; P = 0.01) and hypovolemia (M3: 7.4 [6.3, 9.7] mL/kg; M4: 5.8 [5.2, 7.4]) mL/kg; P = 0.0009). CONCLUSION: Configuration of the thermodilution curve and therefore assessment of GEDI and EVLWI are significantly affected by 1-lung ventilation.


Assuntos
Água Extravascular Pulmonar/fisiologia , Pulmão/fisiologia , Ventilação Monopulmonar/métodos , Volume Sistólico/fisiologia , Animais , Feminino , Hipovolemia/diagnóstico , Hipovolemia/fisiopatologia , Ventilação Monopulmonar/normas , Sus scrofa , Termodiluição/métodos , Termodiluição/normas
18.
Intensive Care Med ; 39(4): 717-26, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23287870

RESUMO

PURPOSE: Severe acute pancreatitis (SAP) remains a life-threatening disease with classic etiology of systemic inflammatory response and mortality between 30 and 50 %. The aim of the present study is to compare two different treatment strategies of goal-directed hemodynamic management and evaluate their impact on survival, microcirculation, tissue oxygenation, and histopathologic damage in acute pancreatitis in a prospective animal study. METHODS: Thirty-four domestic pigs were randomly assigned to two different treatment groups. After induction of acute pancreatitis, in group 1 volume administration was guided by central venous pressure (CVP >12 mmHg) and mean arterial pressure (MAP). In group 2, hemodynamic management was guided primarily by left-ventricular stroke volume variation (SVV <10 %), MAP, and cardiac output (CO). Treatment according to randomization was performed for 6 h, and tissue oxygen tension in the pancreas and pancreatic microcirculation were evaluated. Thereafter, animals were observed for 7 days and then sacrificed. Standardized tissue specimens were taken post mortem, and histopathologic scoring was performed. RESULTS: Survival after 7 days was 29.4 % in group 2 versus 11.8 % in group 1 (p < 0.05). Pancreatic oxygen tension (138.0 ± 89.5 mmHg versus 71.1 ± 35.3 mmHg; p < 0.05) and pancreatic microcirculation (1,209.9 ± 630 AU versus 732 ± 315 AU; p < 0.05) were significantly higher in group 2. Significantly less histopathologic damage within the pancreas could be analyzed post mortem in group 2. CONCLUSIONS: Goal-directed hemodynamic management guided by stroke volume variation led to improved survival, tissue oxygenation, and microcirculatory perfusion, as well as less histopathologic damage in an animal model of severe acute pancreatitis.


Assuntos
Hemodinâmica/fisiologia , Oxigênio/metabolismo , Pâncreas/irrigação sanguínea , Pancreatite/terapia , Animais , Pressão Arterial/fisiologia , Pressão Venosa Central/fisiologia , Modelos Animais de Doenças , Microcirculação/fisiologia , Pancreatite/patologia , Pancreatite/fisiopatologia , Volume Sistólico/fisiologia , Análise de Sobrevida , Suínos
19.
Intensive Care Med ; 39(4): 601-11, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23287875

RESUMO

PURPOSE: Transcardiopulmonary thermodilution (TPTD, SVTD) as well as calibrated (SVPC CAL) and uncalibrated (SVPC UNCAL) arterial pulse contour analysis (PC) are increasingly promoted as less-invasive technologies to measure stroke volume (SV) but their reliability in aortic valve disease was unknown. The objective of this prospective study was to investigate the validity of three less-invasive techniques to assess SV in conditions involving aortic stenosis (AS) and valvuloplasty-induced aortic insufficiency (AI) compared with transesophageal echocardiography. METHODS: In 18 patients undergoing transcatheter aortic valve implantation, SVTD and SVPC CAL were determined using a central pressure signal via the brachial artery and SVPC UNCAL using a peripheral radial signal. RESULTS: In aortic valve dysfunction TPTD achieved adequate reproducibility (concordance correlation coefficient (CCC): AS 0.84; AI 0.82) and agreement (percentage error (PE): AS 26.3 %; AI 26.2 %) with the reference technique. In severe AS, SVPC CAL (PE 25.7 %; CCC 0.85) but not SVPC UNCAL (PE 50.4 %; CCC 0.38) was reliable. Neither calibrated nor uncalibrated PC (SVPC CAL: PE 51.5 %; CCC 0.49; SVPC UNCAL: PE 61.9 %; CCC 0.22) was valid in AI. Trending ability to hemodynamic changes, quantified by the ΔSV vector and the angle θ, was acceptable for each measurement modality. CONCLUSIONS: Transcardiopulmonary thermodilution is valid in aortic valve dysfunction. Calibration of PC substantially improves reliability in aortic valve disease. Calibrated PC is valid in severe AS. Valvuloplasty-induced AI seriously confounds PC measurements. In uncalibrated PC approaches, the relative SV trend is superior to single absolute values.


Assuntos
Débito Cardíaco/fisiologia , Cardiopatias Congênitas/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Feminino , Alemanha , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Pulso Arterial , Volume Sistólico/fisiologia , Termodiluição/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...