Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
AJNR Am J Neuroradiol ; 43(8): 1158-1163, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35863779

RESUMO

BACKGROUND AND PURPOSE: Treatment of PICA aneurysms can be technically challenging by either surgical or endovascular means. Our aim was to report our preliminary experience with intrasaccular flow disruption using the Woven EndoBridge (WEB) for the treatment of proximal PICA aneurysms. MATERIALS AND METHODS: Sixteen PICA aneurysms treated with the WEB at 3 institutions were retrospectively reviewed. Baseline patient and aneurysm characteristics, procedural specifics, clinical outcomes, and angiographic results were evaluated. RESULTS: All aneurysms were located at the proximal, anteromedullary segment of the PICA. Seven aneurysms were ruptured. The median aneurysm size was 3.9 mm (range, 2-12 mm), and all aneurysms were wide-neck. WEB deployment failed in 1 case due to WEB protrusion in a small PICA aneurysm. Additional stent implantation was required for 2 aneurysms to improve intra-aneurysmal WEB positioning. One patient developed a partial posterior cerebral artery territory infarction with transient hemianopsia. Intraoperative rerupture of a ruptured aneurysm could be immediately stopped by WEB deployment due to intrasaccular stasis; however, it might have contributed to a slight disability of the patient. At last angiographic follow-up, 12/15 aneurysms (80%) were completely occluded and 3/15 (20%) had a neck remnant. CONCLUSIONS: The preliminary results indicate that WEB treatment of proximal PICA aneurysms is feasible with a reasonable safety and efficacy profile. The advantages of intrasaccular flow disruption include preservation of the PICA, durable aneurysm occlusion, and omission of antiplatelet therapy. The low-profile WEB 17 delivery system might enable navigation to distal PICA aneurysms, which needs to be addressed further.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Embolização Terapêutica/métodos , Artéria Vertebral , Procedimentos Endovasculares/métodos
2.
Radiography (Lond) ; 28(2): 433-439, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34716089

RESUMO

INTRODUCTION: While tin prefiltration is established in various CT applications, its value in extremity cone-beam CT relative to optimized spectra has not been thoroughly assessed thus far. This study aims to investigate the effect of tin filters in extremity cone-beam CT with a twin-robotic X-ray system. METHODS: Wrist, elbow and ankle joints of two cadaveric specimens were examined in a laboratory setup with different combinations of prefiltration (copper, tin), tube voltage and current-time product. Image quality was assessed subjectively by five radiologists with Fleiss' kappa being computed to measure interrater agreement. To provide a semiquantitative criterion for image quality, contrast-to-noise ratios (CNR) were compared for standardized regions of interest. Volume CT dose indices were calculated for a 16 cm polymethylmethacrylate phantom. RESULTS: Radiation dose ranged from 17.4 mGy in the clinical standard protocol without tin filter to as low as 0.7 mGy with tin prefiltration. Image quality ratings and CNR for tin-filtered scans with 100 kV were lower than for 80 kV studies with copper prefiltration despite higher dose (11.2 and 5.6 vs. 4.5 mGy; p < 0.001). No difference was ascertained between 100 kV scans with tin filtration and 60 kV copper-filtered scans with 75% dose reduction (subjective: p = 0.101; CNR: p = 0.706). Fleiss' kappa of 0.597 (95% confidence interval 0.567-0.626; p < 0.001) indicated moderate interrater agreement. CONCLUSION: Considerable dose reduction is feasible with tin prefiltration, however, the twin-robotic X-ray system's low-dose potential for extremity 3D imaging is maximized with a dedicated low-kilovolt scan protocol in situations without extensive beam-hardening artifacts. IMPLICATIONS FOR PRACTICE: Low-kilovolt imaging with copper prefiltration provides a superior trade-off between dose reduction and image quality compared to tin-filtered cone-beam CT scan protocols with higher tube voltage.


Assuntos
Procedimentos Cirúrgicos Robóticos , Estanho , Tomografia Computadorizada de Feixe Cônico/métodos , Cobre , Extremidades , Humanos , Doses de Radiação , Raios X
3.
J Clin Neurosci ; 89: 33-38, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34119289

RESUMO

BACKGROUND: Complete reperfusion (mTICI 3) in anterior circulation ischemic stroke patients after a single mechanical thrombectomy (MT) pass has been identified as a predictor of favorable outcome (modified Rankin Score 0-2) and defined as true first-pass effect recently. This effect has not yet been demonstrated in posterior circulation ischemic stroke. We hypothesized a true first-pass effect for the subgroup of acute basilar artery occlusions (BAO). METHODS: Consecutive patients with acute thromboembolic occlusions in the posterior circulation, treated between 2010 and 2017, were screened and all BAO patients with complete angiographic reperfusion and known symptom onset included for unmatched and matched analysis after adjustment for multiple confounding factors (demographics, time intervals, stroke severity, posterior circulation Alberta Stroke Program early computed tomography Score and comorbidity. The primary objective was outcome at 90 days between matched cohorts of single pass vs. multi pass complete reperfusion patients. RESULTS: 90 MTs in BAO were analyzed, yielding 56 patients with known symptom onset, in whom we achieved complete reperfusion (mTICI 3), depending on whether complete reperfusion was achieved after a single pass (n = 28) or multiple passes (n = 28). Multivariable analysis of 56 non-matched patients revealed a significant association between first-pass complete reperfusion and favorable outcome (p < 0.01). In matched cohorts (n = 7 vs. n = 7), favorable outcome was only seen if complete reperfusion was achieved after a single pass (86% vs. 0%). CONCLUSION: Single pass complete reperfusion in acute basilar artery occlusion is an independent predictor of favorable outcome. Achieving complete reperfusion after multiple passes might impair favorable patient recovery.


Assuntos
Artéria Basilar/cirurgia , Revascularização Cerebral/métodos , Transtornos Cerebrovasculares/cirurgia , Acidente Vascular Cerebral/cirurgia , Trombectomia/tendências , Idoso , Idoso de 80 Anos ou mais , Artéria Basilar/diagnóstico por imagem , Transtornos Cerebrovasculares/complicações , Transtornos Cerebrovasculares/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reperfusão/métodos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Trombectomia/métodos , Resultado do Tratamento
4.
AJNR Am J Neuroradiol ; 42(4): 655-662, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33541907

RESUMO

BACKGROUND AND PURPOSE: Malignant melanoma is an aggressive skin cancer in which brain metastases are common. Our aim was to establish and evaluate a deep learning model for fully automated detection and segmentation of brain metastases in patients with malignant melanoma using clinical routine MR imaging. MATERIALS AND METHODS: Sixty-nine patients with melanoma with a total of 135 brain metastases at initial diagnosis and available multiparametric MR imaging datasets (T1-/T2-weighted, T1-weighted gadolinium contrast-enhanced, FLAIR) were included. A previously established deep learning model architecture (3D convolutional neural network; DeepMedic) simultaneously operating on the aforementioned MR images was trained on a cohort of 55 patients with 103 metastases using 5-fold cross-validation. The efficacy of the deep learning model was evaluated using an independent test set consisting of 14 patients with 32 metastases. Manual segmentations of metastases in a voxelwise manner (T1-weighted gadolinium contrast-enhanced imaging) performed by 2 radiologists in consensus served as the ground truth. RESULTS: After training, the deep learning model detected 28 of 32 brain metastases (mean volume, 1.0 [SD, 2.4] cm3) in the test cohort correctly (sensitivity of 88%), while false-positive findings of 0.71 per scan were observed. Compared with the ground truth, automated segmentations achieved a median Dice similarity coefficient of 0.75. CONCLUSIONS: Deep learning-based automated detection and segmentation of brain metastases in malignant melanoma yields high detection and segmentation accuracy with false-positive findings of <1 per scan.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Melanoma , Neoplasias Cutâneas , Automação , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/secundário , Humanos , Imageamento por Ressonância Magnética , Melanoma/diagnóstico por imagem , Melanoma/secundário , Neoplasias Cutâneas/diagnóstico por imagem
5.
AJNR Am J Neuroradiol ; 42(3): 516-523, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33384288

RESUMO

BACKGROUND AND PURPOSE: CTA provides a noninvasive alternative technique to DSA in the follow-up after endovascular aneurysm treatment to evaluate aneurysm occlusion and exclude intraluminal narrowing after stent or flow-diverter implantation; however, assessability may be impeded by stent material artifacts. The objective of this in vitro study was to compare the visual assessability of different conventional stents and flow diverters as well as different reconstructions of dual-layer CT images. MATERIALS AND METHODS: Four conventional intracranial stents and 4 flow diverters were implanted in identical aneurysm phantoms. Conventional and monoenergetic images (40, 50, 60, 90, 120, 180 keV) were acquired to evaluate attenuation alteration, visible lumen diameter, and SNR. Image quality was rated subjectively by 2 independent radiologists using a 4-point Likert scale. RESULTS: Low kiloelectron volt (40-60 keV) monoenergetic reconstructions showed an improved SNR and an improved lumen density ratio compared with high kiloelectron volt reconstructions (90-180 keV) and conventional reconstructions, however without reaching significance compared with the latter. Assessment of the adjacent aneurysm and subjective evaluation was not affected by the imaging technique and stent type. Artifact susceptibility varied with the device used and increased among flow diverters. CONCLUSIONS: Low kiloelectron volt reconstructions improved the assessment of the stent lumen in comparison with high kiloelectron volt reconstructions. No significant improvement in image quality could be shown compared with conventional images. For some devices, iodine-specific reconstructions led to severe artifacts and are therefore not recommended. There was no relevant improvement in the assessability of the adjacent aneurysm.


Assuntos
Aneurisma/diagnóstico por imagem , Aneurisma/terapia , Angiografia por Tomografia Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Artefatos , Procedimentos Endovasculares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Stents
6.
Eur Radiol ; 31(6): 4148-4155, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33341907

RESUMO

OBJECTIVES: The objective of this study was to compare clinical outcome and procedural differences of mechanical thrombectomy (MT) during on-call with regular operating hours. We particularly focused on dosimetric data which may serve as potential surrogates for patient outcome. METHODS: A total of 246 consecutive patients who underwent MT in acute anterior circulation stroke between November 2017 and March 2020 were retrospectively included. Patients treated (1) during standard operational hours (n = 102), (2) daytime on-call duty (n = 38) and (3) nighttime on-call duty (n = 106) were compared with respect to their pre-interventional status, procedural specifics, including dosimetrics (dose area product (DAP), fluoroscopy time and procedural time), and outcome. RESULTS: The collectives treated outside the regular operational hours showed an increased in-hospital mortality (standard operational hours 7% (7/102), daytime on-call duty 16% (6/38), nighttime on-call duty 20% (21/106), p = 0.02). Neither the dosimetric parameters nor baseline characteristics other procedural specifics and outcome parameters differed significantly between groups (p > 0.05 each). In most cases (> 90%), a successful reperfusion was achieved (TICI ≥ 2b). CONCLUSIONS: We found an increased in-hospital mortality in patients admitted at night and during weekends which was not explained by technical aspects of MT. KEY POINTS: • There is an increased mortality of stroke patients admitted at night and on weekends. • This is not explained by technical aspects of mechanical thrombectomy. • There were no statistical differences in the comparison of parameters linked to the radiation exposure, such as DAP, fluoroscopy time and procedure time.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Reperfusão , Estudos Retrospectivos , Acidente Vascular Cerebral/terapia , Trombectomia , Resultado do Tratamento
7.
J Clin Neurosci ; 75: 117-121, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32173154

RESUMO

Stent protected Angioplasty of extracranial carotid artery stenosis using the dual-layered CGUARD stent is a novel treatment option. In this study we evaluate the feasibility and the safety of the CGUARD in symptomatic and asymptomatic patients in comparison to Casper-RX and Wallstent. This is a multi-center study of consecutive patients treated with the CGUARD, Casper-RX and Wallstent at two German high volume neurovascular centers between April 2017 and May 2018. Patient characteristics, neuroimaging data and angiographic outcome were retrospectively analyzed. The primary end points of the study were acute occlusion of the carotid stent and symptomatic intracerebral hemorrhage (sICH). Carotid artery stenting was performed in 76 patients; of those 26 (34%) were treated with the CGUARD, 25 (33%) with Casper-RX, and 25 (33%) with Wallstent. In 58/76 (76%) cases carotid artery stenosis was symptomatic with a median baseline National Institutes of Health Stroke Scale of 4. Angioplasty and stenting as part of a mechanical thrombectomy for acute ischemic stroke was performed in 25/76 (33%) patients. Baseline patient characteristics were similar between the treatment groups, except for a higher portion of scheduled cases in the Casper-RX group. There were no significant differences in the rate of acute in stent occlusions (CGUARD, 2/26 (8%); Casper-RX, 1/25(4%); Wallstent, 1/25 (4%)) and postinterventional sICH (1/26 (4%), 0/25(0%), 0/25 (0%)). Clinical outcome at discharge did not differ between groups. Treatment of carotid artery stenosis using CGUARD is feasible with a good safety profile comparable to that of Casper-RX and Wallstent.


Assuntos
Estenose das Carótidas/terapia , Stents/normas , Idoso , Angioplastia/métodos , Isquemia Encefálica/terapia , Estenose das Carótidas/cirurgia , Procedimentos Endovasculares/métodos , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/terapia , Resultado do Tratamento
8.
AJNR Am J Neuroradiol ; 40(10): 1766-1772, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31488499

RESUMO

BACKGROUND AND PURPOSE: The Woven EndoBridge 17 has recently been introduced to the market for facilitated endovascular treatment of small bifurcation aneurysms (≤7 mm) with low-profile microcatheters. We compared the Woven EndoBridge 17 with its predecessor versions in terms of procedural safety and feasibility. MATERIALS AND METHODS: This was a multicenter review of aneurysms ranging from 3 to 7 mm treated with the Woven EndoBridge between 2011 and 2019. Aneurysm characteristics, procedural parameters, and complications were retrospectively compared between treatment with the Woven EndoBridge 17 and a control group that was treated with its predecessor versions, using inverse probability of treatment weighting. RESULTS: Thirty-eight aneurysms treated with a Woven EndoBridge 17 (mean size, 4.9 ± 1.5 mm) and 70 treated with a predecessor version of the Woven EndoBridge 17 (mean size, 5.6 ± 1.4 mm) were included. The predecessor version of the Woven EndoBridge 17 had a higher failure rate (10.3%) than the Woven EndoBridge 17 (0%, P = .05). Additional stent placement was performed more often with the predecessor version of the Woven EndoBridge 17 (10.0%) than with the Woven EndoBridge 17 (2.6%, adjusted P = .005). The predecessor version of the Woven EndoBridge 17 was associated with a higher thromboembolic event rate (14.3%) than the Woven EndoBridge 17 (5.3%, adjusted P = .002). Neurologic complications (Woven EndoBridge 17: 2.6%; predecessor version of the Woven EndoBridge 17: 2.9%, adjusted P = 1.0) and immediate complete aneurysm occlusion rates (Woven EndoBridge 17: 57.9%; predecessor version of the Woven EndoBridge 17: 54.3%, adjusted P = .21) did not differ significantly between groups. CONCLUSIONS: In the current study, the Woven EndoBridge 17 was associated with a potentially lower thromboembolic event rate than the predecessor version of the Woven EndoBridge 17, without compromising the immediate aneurysm occlusion rate. Long-term clinical and angiographic outcome analysis will be necessary to draw a definite conclusion.


Assuntos
Prótese Vascular , Embolização Terapêutica/instrumentação , Procedimentos Endovasculares/instrumentação , Aneurisma Intracraniano/terapia , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular/efeitos adversos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...