Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
FASEB J ; 29(7): 3100-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25857553

RESUMO

Currently, there are no generally applicable noninvasive methods for defining the relationship between atherosclerotic vascular damage and risk of focal thrombosis. Herein, we demonstrate methods to delineate the progression and regression of vascular damage in response to an atherogenic diet by quantifying the in vivo accumulation of semipermeable 200-300 nm perfluorocarbon core nanoparticles (PFC-NP) in ApoE null mouse plaques with [(19)F] magnetic resonance spectroscopy (MRS). Permeability to PFC-NP remained minimal until 12 weeks on diet, then increased rapidly following 12 weeks, but regressed to baseline within 8 weeks after diet normalization. Markedly accelerated clotting (53.3% decrease in clotting time) was observed in carotid artery preparations of fat-fed mice subjected to photochemical injury as defined by the time to flow cessation. For all mice on and off diet, an inverse linear relationship was observed between the permeability to PFC-NP and accelerated thrombosis (P = 0.02). Translational feasibility for quantifying plaque permeability and vascular damage in vivo was demonstrated with clinical 3 T MRI of PFC-NP accumulating in plaques of atherosclerotic rabbits. These observations suggest that excessive permeability to PFC-NP may indicate prothrombotic risk in damaged atherosclerotic vasculature, which resolves within weeks after dietary therapy.


Assuntos
Aterosclerose/complicações , Trombose/etiologia , Animais , Apolipoproteínas E/deficiência , Apolipoproteínas E/genética , Aterosclerose/dietoterapia , Aterosclerose/etiologia , Permeabilidade Capilar , Colesterol/química , Colesterol/metabolismo , Cristalização , Dieta Aterogênica/efeitos adversos , Dieta Ocidental/efeitos adversos , Modelos Animais de Doenças , Progressão da Doença , Endotélio Vascular/patologia , Endotélio Vascular/fisiopatologia , Fluorocarbonos , Imageamento por Ressonância Magnética , Masculino , Camundongos , Camundongos Knockout , Nanopartículas , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico , Coelhos , Fatores de Risco
2.
Magn Reson Med ; 74(2): 537-43, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25163853

RESUMO

PURPOSE: A novel technique for highly sensitive detection of multiresonant fluorine imaging agents was designed and tested with the use of dual-frequency 19F/1H ultrashort echo times (UTE) sampled with a balanced steady-state free precession (SSFP) pulse sequence and three-dimensional (3D) radial readout. METHODS: Feasibility of 3D radial balanced UTE-SSFP imaging was demonstrated for a phantom comprising liquid perfluorooctyl bromide (PFOB). Sensitivity of the pulse sequence was measured and compared with other sequences imaging the PFOB (CF2 )6 line group including UTE radial gradient-echo (GRE) at α = 30°, as well as Cartesian GRE, balanced SSFP, and fast spin-echo (FSE). The PFOB CF3 peak was also sampled with FSE. RESULTS: The proposed balanced UTE-SSFP technique exhibited a relative detection sensitivity of 51 µmolPFOB(-1) min(-1/2) (α = 30°), at least twice that of other sequence types with either 3D radial (UTE GRE: 20 µmolPFOB(-1) min(-1/2) ) or Cartesian k-space filling (GRE: 12 µmolPFOB(-1) min(-1/2) ; FSE: 16 µmolPFOB(-1) min(-1/2) ; balanced SSFP: 23 µmolPFOB(-1) min(-1/2) ). In vivo imaging of angiogenesis-targeted PFOB nanoparticles was demonstrated in a rabbit model of cancer on a clinical 3 Tesla scanner. CONCLUSION: A new dual 19F/1H balanced UTE-SSFP sequence manifests high SNR, with detection sensitivity more than two-fold better than traditional techniques, and alleviates imaging problems caused by dephasing in complex spectra.


Assuntos
Algoritmos , Imagem por Ressonância Magnética de Flúor-19/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Experimentais/patologia , Processamento de Sinais Assistido por Computador , Animais , Estudos de Viabilidade , Feminino , Imagem por Ressonância Magnética de Flúor-19/instrumentação , Humanos , Aumento da Imagem/métodos , Masculino , Imagens de Fantasmas , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
J Magn Reson Imaging ; 42(2): 488-94, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25425244

RESUMO

PURPOSE: To improve (19) F flip angle calibration and compensate for B1 inhomogeneities in quantitative (19) F MRI of sparse molecular epitopes with perfluorocarbon (PFC) nanoparticle (NP) emulsion contrast agents. MATERIALS AND METHODS: Flip angle sweep experiments on PFC-NP point source phantoms with three custom-designed (19) F/(1) H dual-tuned coils revealed a difference in required power settings for (19) F and (1) H nuclei, which was used to calculate a calibration ratio specific for each coil. An image-based correction technique was developed using B1 -field mapping on (1) H to correct for (19) F and (1) H images in two phantom experiments. RESULTS: Optimized (19) F peak power differed significantly from that of (1) H power for each coil (P < 0.05). A ratio of (19) F/(1) H power settings yielded a coil-specific and spatially independent calibration value (surface: 1.48 ± 0.06; semicylindrical: 1.71 ± 0.02, single-turn-solenoid: 1.92 ± 0.03). (1) H-image-based B1 correction equalized the signal intensity of (19) F images for two identical (19) F PFC-NP samples placed in different parts of the field, which were offset significantly by ~66% (P < 0.001), before correction. CONCLUSION: (19) F flip angle calibration and B1 -mapping compensations to the (19) F images employing the more abundant (1) H signal as a basis for correction resulted in a significant change in the quantification of sparse (19) F MR signals from targeted PFC NP emulsions.


Assuntos
Algoritmos , Artefatos , Imageamento por Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/instrumentação , Imagem Molecular/métodos , Calibragem , Desenho de Equipamento , Análise de Falha de Equipamento , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Nanomedicine (Lond) ; 6(4): 605-15, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21506686

RESUMO

AIM: To develop a fibrin-specific urokinase nanomedicine thrombolytic agent. MATERIALS & METHODS: In vitro fibrin-clot dissolution studies were utilized to develop and characterize simultaneous coupling and loading of anti-fibrin monoclonal antibody and urokinase onto perfluorocarbon nanoparticle (NP) surface. In vivo pharmacokinetics and fibrin-specific targeting of the nanolytic agent was studied in dogs. RESULTS: Simultaneous coupling of up to 40 anti-fibrin antibodies and 400 urokinase enzymes per perfluorocarbon NP produced an effective targeted nanolytic agent with no significant surface protein-protein interference. Fibrin clot dissolution was not improved by increasing homing capacity from 10 to 40 antibodies/NP, but increasing enzymatic payload from 100 to 400/NP resulted in maximized lytic effect. Fluorescent microscopy showed that rhodamine-labeled urokinase nanoparticles densely decorated the intraluminal thrombus in canine clots in vivo analogous to the fibrin pattern, while an irrelevant-targeted agent had negligible binding. CONCLUSION: This agent offers a vascularly constrained, simple to administer, low-dose nanomedicine approach that may present an attractive alternative for treating acute stroke victims.


Assuntos
Fibrina/metabolismo , Nanomedicina/métodos , Nanopartículas/uso terapêutico , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/metabolismo , Animais , Cães , Fluorocarbonos/química , Nanopartículas/química , Ativador de Plasminogênio Tipo Uroquinase/química , Ativador de Plasminogênio Tipo Uroquinase/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...