J Craniomaxillofac Surg ; 40(8): e487-97, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22516866

RESUMO

INTRODUCTION: Problems with loosening of the modules for the modular endoprosthesis were encountered in animal studies for mandibular body replacement. We performed a finite element analysis to look at the stress distribution and areas of stress concentration in a human sized mandible. Variations were made to the stem and defect length to look at how the forces changed. The hypothesis was: (1) reconstruction with a modular endoprosthesis did not lead to areas of stress concentration beyond the material strength of cortical bone and titanium alloy; (2) changes in dimensions of the endoprosthesis did not cause a corresponding linear increase to the stresses. MATERIALS AND METHODS: The endoprosthesis was modelled to create a male, female part with stems and a connection screw (Case I). The stem length was halved (Case II) and defect length doubled (Case III). Geometric data of a human sized mandible were obtained, a continuity defect created digitally at the right molar area and the models combined. Boundary conditions were set and the model loaded to get a bite force of 300 N at the incisor region. An intact mandible was used as a control. RESULTS: The right side of the reconstructed mandible became less rigid and flexed more. The highest stresses were within the endoprosthesis at two areas of stress concentration: (1) shear stress at the superior surface of the stems close to the junction of the stem and the module body; (2) compressive stresses at the bottom bevel of the dove-tailed connection. The stress distribution for Case I and II did not differ much except for the magnitude which was slightly higher for Case II. There was a tendency for outward bending at the module connection for Case III which potentially might cause loosening of the module connection. Displacements of the mandible were less than 1 mm throughout. CONCLUSION: The endoprosthesis with its present dimensions would be expected to perform adequately at a bite force of 300 N. An increase in defect length caused a tendency for bending at the stem and the module connection. With a decrease in stem length, there were little differences except a slight increase in magnitude.


Assuntos
Análise de Elementos Finitos , Reconstrução Mandibular/instrumentação , Procedimentos de Cirurgia Plástica/instrumentação , Próteses e Implantes , Desenho de Prótese , Ligas/química , Fenômenos Biomecânicos , Força de Mordida , Simulação por Computador , Humanos , Mandíbula/fisiopatologia , Músculos da Mastigação/fisiopatologia , Teste de Materiais , Modelos Biológicos , Maleabilidade , Falha de Prótese , Estresse Mecânico , Propriedades de Superfície , Titânio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...