RESUMO
We reported a case of heterotopic twin pregnancy in a unicornuate uterus with a non-communicating rudimentary horn with survival of both fetuses. The diagnosis was made late at 28 weeks of gestation, with suspicion raised by ultrasound and confirmed by magnetic resonance imaging (MRI). During hospitalization, obstetric ultrasound with color Doppler was performed every 2 days to assess fetal well-being and myometrial thickness, which was determined by measurements of the uterine wall at the accessory horn. Elective cesarean section was performed at 33 + 5 weeks of gestation. Delivery started with the fetus in the rudimentary horn, with subsequent extraction of the fetus in the unicornate uterus. Three-dimensional virtual reconstruction allowed a spatial view of the both uterus and fetuses with better understanding of the obstetrical condition by the parents and interactive discussion by the multidisciplinary medical team.
Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Gravidez de Gêmeos , Útero , Humanos , Feminino , Gravidez , Imageamento Tridimensional/métodos , Útero/anormalidades , Útero/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Gravidez Heterotópica/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Anormalidades Urogenitais/diagnóstico por imagemRESUMO
Background and study aims There are rare data on the usefulness of endosonography-guided tissue acquisition (EUS-TA) in patients with pancreatic cystic lesions (PCLs). This study aimed to determine the accuracy of EUS-TA with ProCore 20G (PC20) for differentiating between mucinous neoplasia (MN) and non-MNs (n-MN) and identifying malignant PCLs, as well as its adverse events (AEs) in patients with PCLs without a classificatory diagnosis by imaging exams. Patients and methods In this observational, retrospective, single-center study, all patients with PCL who underwent EUS-TA due to diagnostic doubts in imaging studies were consecutively recruited from June 2017 to December 2021. The outcomes were to determine the diagnostic accuracy of EUS-TA with PC20 for differentiating between MN and n-MN, identifying malignant PCLs, and the AEs. Results Herein, 145 patients underwent EUS-TA, with 83 women (57.2%) and a mean age of 62.2 years. The mean size was 2.3 cm, with 81 patients (77.9%) having a PCL < 3.0 cm. The final diagnosis was made by EUS-TA (n = 81), surgery (n = 58), and follow-up (n = 6). The sensitivity, specificity, positive and negative predictive values, and accuracy for differentiating between MNs and n-MNs and identifying malignant PCLs were 92.6%, 98.4%, 98.7%, 91.3%, and 95.2% (kappa=0.9), and 92%, 99.2%, 95.8%, 98.3%, and 97.9% (kappa = 0.93), respectively. The AE rate was 2.7%, with no deaths in this cohort. Conclusions EUS-TA with PC20 has high accuracy and technical success with a low AE rate for PCL diagnosis.
RESUMO
Objective: To evaluate the safety and efficacy of using highly compressible calibrated microspheres in uterine artery embolization (UAE) for the treatment of uterine fibroids. Materials and Methods: This was a prospective multicenter study. Thirty-two women with symptomatic uterine fibroids were selected for UAE between January 2019 and March 2020. The participants completed the Uterine Fibroid Symptom and Quality of Life (UFS-QOL) questionnaire, underwent contrast-enhanced pelvic magnetic resonance imaging (MRI), and were submitted to anti-Müllerian hormone measurement, subsequently undergoing UAE with Embosoft microspheres. After six months, the patients again completed the UFS-QOL questionnaire and underwent pelvic MRI. Results: The most common symptoms were abnormal uterine bleeding (in 81.3% of the cases), pelvic pain (in 81.3%), and compression (in 46.9%). Of the 32 patients evaluated, 12 (37.5%) had anemia due to abnormal uterine bleeding. Thirty patients completed the study. Among those patients, we observed median reductions of 21.4% in uterine volume and 15.9% in dominant fibroid volume. We identified no adverse events that could be attributed to the material itself, although there were events attributed to the UAE procedure in general. Conclusion: For the treatment of uterine fibroids, UAE using Embosoft microspheres shows satisfactory results, providing reductions in uterine and dominant fibroid volumes, with a low rate of adverse events, and improving patient quality of life, as well as demonstrating safety and efficacy.
Objetivo: Avaliar a eficácia e segurança da embolização da artéria uterina (EAU) com microesferas calibradas de alta compressibilidade no tratamento de miomas uterinos. Materiais e Métodos: Este foi um estudo prospectivo e multicêntrico. Foram selecionadas 32 mulheres com miomas uterinos sintomáticos para EAU de janeiro de 2019 a março de 2020. As participantes preencheram o questionário Uterine Fibroid Symptom and Quality of Life (UFS-QOL), realizaram ressonância magnética (RM) pélvica com contraste e teste para medição dos hormônios antimüllerianos, seguido de embolização de miomas com microesferas Embosoft. Após seis meses, as pacientes novamente preencheram o UFS-QOL e realizaram RM pélvica. Resultados: Os sintomas mais relatados foram sangramento uterino anormal (81,3%), dor pélvica (81,3%) e compressão (46,9%). Doze pacientes (37,5%) apresentaram anemia consequente a sangramento uterino anormal. Nas 30 pacientes que completaram o estudo, observou-se redução mediana de 21,4% no volume uterino e 15,9% no volume do mioma dominante. Não foram identificados eventos adversos possivelmente relacionados ao material utilizado, apenas em relação ao procedimento de EAU. Conclusão: EAU com microesferas Embrosoft mostrou resultados satisfatórios no tratamento de miomas uterinos, com redução dos volumes uterino e do mioma dominante, baixa taxa de eventos adversos e melhora na qualidade de vida, demonstrando segurança e eficácia.
RESUMO
OBJECTIVE: To evaluate the safety and efficacy of using highly compressible calibrated microspheres in uterine artery embolization (UAE) for the treatment of uterine fibroids. MATERIALS AND METHODS: This was a prospective multicenter study. Thirty-two women with symptomatic uterine fibroids were selected for UAE between January 2019 and March 2020. The participants completed the Uterine Fibroid Symptom and Quality of Life (UFS-QOL) questionnaire, underwent contrast-enhanced pelvic magnetic resonance imaging (MRI), and were submitted to anti-Müllerian hormone measurement, subsequently undergoing UAE with Embosoft microspheres. After six months, the patients again completed the UFS-QOL questionnaire and underwent pelvic MRI. RESULTS: The most common symptoms were abnormal uterine bleeding (in 81.3% of the cases), pelvic pain (in 81.3%), and compression (in 46.9%). Of the 32 patients evaluated, 12 (37.5%) had anemia due to abnormal uterine bleeding. Thirty patients completed the study. Among those patients, we observed median reductions of 21.4% in uterine volume and 15.9% in dominant fibroid volume. We identified no adverse events that could be attributed to the material itself, although there were events attributed to the UAE procedure in general. CONCLUSION: For the treatment of uterine fibroids, UAE using Embosoft microspheres shows satisfactory results, providing reductions in uterine and dominant fibroid volumes, with a low rate of adverse events, and improving patient quality of life, as well as demonstrating safety and efficacy.
OBJETIVO: Avaliar a eficácia e segurança da embolização da artéria uterina (EAU) com microesferas calibradas de alta compressibilidade no tratamento de miomas uterinos. MATERIAIS E MÉTODOS: Este foi um estudo prospectivo e multicêntrico. Foram selecionadas 32 mulheres com miomas uterinos sintomáticos para EAU de janeiro de 2019 a março de 2020. As participantes preencheram o questionário Uterine Fibroid Symptom and Quality of Life (UFS-QOL), realizaram ressonância magnética (RM) pélvica com contraste e teste para medição dos hormônios antimüllerianos, seguido de embolização de miomas com microesferas Embosoft. Após seis meses, as pacientes novamente preencheram o UFS-QOL e realizaram RM pélvica. RESULTADOS: Os sintomas mais relatados foram sangramento uterino anormal (81,3%), dor pélvica (81,3%) e compressão (46,9%). Doze pacientes (37,5%) apresentaram anemia consequente a sangramento uterino anormal. Nas 30 pacientes que completaram o estudo, observou-se redução mediana de 21,4% no volume uterino e 15,9% no volume do mioma dominante. Não foram identificados eventos adversos possivelmente relacionados ao material utilizado, apenas em relação ao procedimento de EAU. CONCLUSÃO: EAU com microesferas Embrosoft mostrou resultados satisfatórios no tratamento de miomas uterinos, com redução dos volumes uterino e do mioma dominante, baixa taxa de eventos adversos e melhora na qualidade de vida, demonstrando segurança e eficácia.
Assuntos
Embolização da Artéria Uterina , Leiomioma , MicroesferasRESUMO
Abstract Objective: To evaluate the safety and efficacy of using highly compressible calibrated microspheres in uterine artery embolization (UAE) for the treatment of uterine fibroids. Materials and Methods: This was a prospective multicenter study. Thirty-two women with symptomatic uterine fibroids were selected for UAE between January 2019 and March 2020. The participants completed the Uterine Fibroid Symptom and Quality of Life (UFS-QOL) questionnaire, underwent contrast-enhanced pelvic magnetic resonance imaging (MRI), and were submitted to anti-Müllerian hormone measurement, subsequently undergoing UAE with Embosoft microspheres. After six months, the patients again completed the UFS-QOL questionnaire and underwent pelvic MRI. Results: The most common symptoms were abnormal uterine bleeding (in 81.3% of the cases), pelvic pain (in 81.3%), and compression (in 46.9%). Of the 32 patients evaluated, 12 (37.5%) had anemia due to abnormal uterine bleeding. Thirty patients completed the study. Among those patients, we observed median reductions of 21.4% in uterine volume and 15.9% in dominant fibroid volume. We identified no adverse events that could be attributed to the material itself, although there were events attributed to the UAE procedure in general. Conclusion: For the treatment of uterine fibroids, UAE using Embosoft microspheres shows satisfactory results, providing reductions in uterine and dominant fibroid volumes, with a low rate of adverse events, and improving patient quality of life, as well as demonstrating safety and efficacy.
Resumo Objetivo: Avaliar a eficácia e segurança da embolização da artéria uterina (EAU) com microesferas calibradas de alta compressibilidade no tratamento de miomas uterinos. Materiais e Métodos: Este foi um estudo prospectivo e multicêntrico. Foram selecionadas 32 mulheres com miomas uterinos sintomáticos para EAU de janeiro de 2019 a março de 2020. As participantes preencheram o questionário Uterine Fibroid Symptom and Quality of Life (UFS-QOL), realizaram ressonância magnética (RM) pélvica com contraste e teste para medição dos hormônios antimüllerianos, seguido de embolização de miomas com microesferas Embosoft. Após seis meses, as pacientes novamente preencheram o UFS-QOL e realizaram RM pélvica. Resultados: Os sintomas mais relatados foram sangramento uterino anormal (81,3%), dor pélvica (81,3%) e compressão (46,9%). Doze pacientes (37,5%) apresentaram anemia consequente a sangramento uterino anormal. Nas 30 pacientes que completaram o estudo, observou-se redução mediana de 21,4% no volume uterino e 15,9% no volume do mioma dominante. Não foram identificados eventos adversos possivelmente relacionados ao material utilizado, apenas em relação ao procedimento de EAU. Conclusão: EAU com microesferas Embrosoft mostrou resultados satisfatórios no tratamento de miomas uterinos, com redução dos volumes uterino e do mioma dominante, baixa taxa de eventos adversos e melhora na qualidade de vida, demonstrando segurança e eficácia.
RESUMO
SARS-CoV-2 infection during pregnancy is not usually associated with significant adverse effects. However, in this study, we report a fetal death associated with mild COVID-19 in a 34-week-pregnant woman. The virus was detected in the placenta and in an unprecedented way in several fetal tissues. Placental abnormalities (MRI and anatomopathological study) were consistent with intense vascular malperfusion, probably the cause of fetal death. Lung histopathology also showed signs of inflammation, which could have been a contributory factor. Monitoring inflammatory response and coagulation in high-risk pregnant women with COVID-19 may prevent unfavorable outcomes, as shown in this case.
RESUMO
OBJECTIVE: This study sought to evaluate the role of diffusion-weighted imaging (DWI) in differentiation between obstructed and unobstructed bile ducts in patients undergoing magnetic resonance imaging (MRI). METHODS: Eighty-four patients, 40 males and 44 females (mean age: 56.4 ± 15.1 years), undergoing MRI with DWI (0-50-500-700) were evaluated and divided into two groups: 58 with abnormal laboratory tests (obstructed group) and 26 with normal laboratory values (unobstructed group). Laboratory tests were total bilirubin, alkaline phosphatase, and gamma-glutamyltransferase. Median ADC values were calculated and correlated with laboratory tests and degree of bile-duct dilatation (absent, moderate, or severe). The persistence of signal on DWI (b500 and b700) in the biliary tract was evaluated. Bilirubin values were tested for correlation with bile-duct ADC values and persistence of b700 signal. For statistical analysis, Student t test, chi-square test and Wilcoxon-Mann-Whitney test were used. ADC maps were plotted for three levels of the biliary tree, and a receiver operating characteristic (ROC) curve was calculated. RESULTS: In the obstructed group, 15 patients had severe dilatation, 24 had moderate dilatation, and 19 had no appreciable dilatation; 38 patients had persistent signal on b700 images. In the unobstructed group, 23 patients had no dilatation and 3 had moderate dilatation; 4 patients had persistent signal on b700 images. Correlation was found between degree of bile-duct dilatation, bilirubin levels, persistence of b700 signal, and ADC map values. The calculated ADC map cutoff value (353 10-6 mm2/s) was able to differentiate the obstructed and unobstructed groups with 92.3% sensitivity, 81% specificity, and 91.9% accuracy. CONCLUSIONS: DWI is able to distinguish patients with obstructed versus unobstructed bile ducts, regardless of the degree of dilatation, correlating with clinical and laboratory findings.
Assuntos
Ductos Biliares , Imagem de Difusão por Ressonância Magnética , Adulto , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e EspecificidadeRESUMO
OBJECTIVE: To assess the practical aspects of the use of various gadolinium-based contrast agents (GBCAs) by radiologists. MATERIALS AND METHODS: Ten experienced radiologists from different regions of Brazil participated in a Delphi panel querying their use of various GBCAs, including linear and macrocyclic classes (1.0 and 0.5 M), in terms of the choice of agent, volume and dosage of the agents, and associated safety concerns. RESULTS: The response rate was 100% for all questions. GBCAs are safe in terms of acute adverse reactions, and nephrogenic systemic fibrosis is rare. The deposition of gadolinium in the brain and other tissues is a concern among the experts. Macrocyclic agents are preferable to linear agents; an injection volume below 0.1 mL/kg of a 1.0 M agent could result in good-quality images with additional long-term safety, but there is no published evidence to support this recommendation. The majority of experts preferred not to administer GBCAs to pregnant patients. CONCLUSION: When choosing a GBCA, it is important to consider the characteristics of the gadolinium deposition in patient tissues and minimize potential risks. Furthermore, medical education programs are needed to increase the awareness of the potential risks of gadolinium deposition and thus avoid instances of overexposure to the contrast agent.
OBJETIVO: Avaliar aspectos práticos do uso de agentes de contraste à base de gadolínio (gadolinium-based contrast agents - GBCAs) por médicos especialistas em radiologia. MATERIAIS E MÉTODOS: Dez radiologistas de diferentes regiões do Brasil foram convidados a participar de um painel Delphi com perguntas sobre o uso de GBCAs lineares e macrocíclicos (1,0 e 0,5 M), em termos de dosagem, volume injetado e preocupações relacionadas à segurança. RESULTADOS: A taxa de resposta foi de 100% para todas as perguntas. GBCAs são seguros em relação a reações adversas agudas, e os casos de fibrose nefrogênica sistêmica são raros. O depósito de gadolínio no cérebro e em outros tecidos é uma preocupação de todo o painel. Agentes macrocíclicos são preferíveis aos lineares. Um volume menor que 0,1 mL/kg injetado de contraste macrocíclico 1,0 M poderia oferecer imagem com boa qualidade e benefício adicional em longo prazo, entretanto, não há evidências publicadas que apóiem tal recomendação. A maioria prefere não administrar GBCA em gestantes. CONCLUSÃO: É importante considerar as características de deposição e minimizar potenciais riscos ao se escolher um GBCA. Ações de educação médica são necessárias para a conscientização dos potenciais riscos da presença de gadolínio em longo prazo e evitar a sobre-exposição ao agente de contraste.
RESUMO
Abstract Objective: To assess the practical aspects of the use of various gadolinium-based contrast agents (GBCAs) by radiologists. Materials and Methods: Ten experienced radiologists from different regions of Brazil participated in a Delphi panel querying their use of various GBCAs, including linear and macrocyclic classes (1.0 and 0.5 M), in terms of the choice of agent, volume and dosage of the agents, and associated safety concerns. Results: The response rate was 100% for all questions. GBCAs are safe in terms of acute adverse reactions, and nephrogenic systemic fibrosis is rare. The deposition of gadolinium in the brain and other tissues is a concern among the experts. Macrocyclic agents are preferable to linear agents; an injection volume below 0.1 mL/kg of a 1.0 M agent could result in good-quality images with additional long-term safety, but there is no published evidence to support this recommendation. The majority of experts preferred not to administer GBCAs to pregnant patients. Conclusion: When choosing a GBCA, it is important to consider the characteristics of the gadolinium deposition in patient tissues and minimize potential risks. Furthermore, medical education programs are needed to increase the awareness of the potential risks of gadolinium deposition and thus avoid instances of overexposure to the contrast agent.
Resumo Objetivo: Avaliar aspectos práticos do uso de agentes de contraste à base de gadolínio (gadolinium-based contrast agents - GBCAs) por médicos especialistas em radiologia. Materiais e Métodos: Dez radiologistas de diferentes regiões do Brasil foram convidados a participar de um painel Delphi com perguntas sobre o uso de GBCAs lineares e macrocíclicos (1,0 e 0,5 M), em termos de dosagem, volume injetado e preocupações relacionadas à segurança. Resultados: A taxa de resposta foi de 100% para todas as perguntas. GBCAs são seguros em relação a reações adversas agudas, e os casos de fibrose nefrogênica sistêmica são raros. O depósito de gadolínio no cérebro e em outros tecidos é uma preocupação de todo o painel. Agentes macrocíclicos são preferíveis aos lineares. Um volume menor que 0,1 mL/kg injetado de contraste macrocíclico 1,0 M poderia oferecer imagem com boa qualidade e benefício adicional em longo prazo, entretanto, não há evidências publicadas que apóiem tal recomendação. A maioria prefere não administrar GBCA em gestantes. Conclusão: É importante considerar as características de deposição e minimizar potenciais riscos ao se escolher um GBCA. Ações de educação médica são necessárias para a conscientização dos potenciais riscos da presença de gadolínio em longo prazo e evitar a sobre-exposição ao agente de contraste.
RESUMO
OBJECTIVE: To investigate the advantages of using modified signal intensity measurements on chemical shift imaging alone or in conjunction with proton magnetic resonance spectroscopy in the differential diagnosis of adrenal adenomas. MATERIALS AND METHODS: This was a prospective study involving 97 patients with adrenal nodules or masses. The signal intensity index (SII) was calculated as [(signal intensity on the in-phase image - signal intensity on the out-of-phase image) ∕ (signal intensity on the in-phase image)] × 100%. We determined the averages of the minimum, mean, and maximum signal intensity values measured on three consecutive images. When that was not possible (for smaller lesions), we used one or two images. We employed a region of interest that covered one half to two thirds of the mass. All indices were compared with metabolite ratios derived from spectroscopy: lactate/creatine; glutamine-glutamate/creatine; choline/creatine; choline/lipid; 4.0-4.3 ppm/Cr; and lipid/creatine. RESULTS: Of the 97 patients evaluated, 69 were diagnosed with adenomas and 28 were diagnosed with nonadenomas. All SII measurements and spectroscopy-derived metabolite ratios were significant to the differentiation between adenomas and nonadenomas, except for the lipid/creatine and choline/lipid ratios. In 37.8% of the cases, it was not possible to perform spectroscopy. When it was possible, the lactate/creatine ratio was found to have higher accuracy than did the SII. CONCLUSION: Determining the SII and metabolite ratios increased the accuracy of the differential diagnosis of adrenal adenomas.
OBJETIVO: Investigar as vantagens do uso de medições do índice de intensidade de sinal modificadas em imagens de deslocamento químico (chemical shift), isoladamente ou em conjunto com a espectroscopia por ressonância magnética de prótons, no diagnóstico diferencial de adenomas adrenais. MATERIAIS E MÉTODOS: Estudo prospectivo envolvendo 97 pacientes com nódulos ou massas adrenais. O índice de intensidade do sinal (SII) foi calculado como [(intensidade do sinal na imagem em fase intensidade do sinal na imagem fora de fase) ∕ (intensidade do sinal na imagem em fase)] × 100%. Determinamos as médias dos valores mínimo, médio e máximo da intensidade do sinal medida em três imagens consecutivas. Quando isso não foi possível (para lesões menores), usamos uma ou duas imagens. Nós empregamos uma região de interesse que cobria de metade a dois terços da massa. Todos os índices foram comparados com razões metabólicas derivadas da espectroscopia: lactato/creatina, glutamato-glutamina/creatina, colina/creatina, colina/lipídio, 4,04,3 ppm/creatina e lipídio/creatina. RESULTADOS: Dos 97 pacientes avaliados, 69 foram diagnosticados como adenomas e 28 foram diagnosticados como não adenomas. Todas as medições SII e razões de metabólitos derivados da espectroscopia foram significativas para a diferenciação entre adenomas e não adenomas, exceto as razões lipídio/creatina e colina/lipídio. Em 37,8% dos casos não foi possível realizar espectroscopia. Quando possível, a razão lactato/creatina apresentou maior precisão do que o SII. CONCLUSÃO: A determinação das razões SII e metabólitos aumentaram a acurácia do diagnóstico diferencial de adenomas adrenais.
RESUMO
Abstract Objective: To investigate the advantages of using modified signal intensity measurements on chemical shift imaging alone or in conjunction with proton magnetic resonance spectroscopy in the differential diagnosis of adrenal adenomas. Materials and Methods: This was a prospective study involving 97 patients with adrenal nodules or masses. The signal intensity index (SII) was calculated as [(signal intensity on the in-phase image − signal intensity on the out-of-phase image) ∕ (signal intensity on the in-phase image)] × 100%. We determined the averages of the minimum, mean, and maximum signal intensity values measured on three consecutive images. When that was not possible (for smaller lesions), we used one or two images. We employed a region of interest that covered one half to two thirds of the mass. All indices were compared with metabolite ratios derived from spectroscopy: lactate/creatine; glutamine-glutamate/creatine; choline/creatine; choline/lipid; 4.0-4.3 ppm/Cr; and lipid/creatine. Results: Of the 97 patients evaluated, 69 were diagnosed with adenomas and 28 were diagnosed with nonadenomas. All SII measurements and spectroscopy-derived metabolite ratios were significant to the differentiation between adenomas and nonadenomas, except for the lipid/creatine and choline/lipid ratios. In 37.8% of the cases, it was not possible to perform spectroscopy. When it was possible, the lactate/creatine ratio was found to have higher accuracy than did the SII. Conclusion: Determining the SII and metabolite ratios increased the accuracy of the differential diagnosis of adrenal adenomas.
Resumo Objetivo: Investigar as vantagens do uso de medições do índice de intensidade de sinal modificadas em imagens de deslocamento químico (chemical shift), isoladamente ou em conjunto com a espectroscopia por ressonância magnética de prótons, no diagnóstico diferencial de adenomas adrenais. Materiais e Métodos: Estudo prospectivo envolvendo 97 pacientes com nódulos ou massas adrenais. O índice de intensidade do sinal (SII) foi calculado como [(intensidade do sinal na imagem em fase - intensidade do sinal na imagem fora de fase) ∕ (intensidade do sinal na imagem em fase)] × 100%. Determinamos as médias dos valores mínimo, médio e máximo da intensidade do sinal medida em três imagens consecutivas. Quando isso não foi possível (para lesões menores), usamos uma ou duas imagens. Nós empregamos uma região de interesse que cobria de metade a dois terços da massa. Todos os índices foram comparados com razões metabólicas derivadas da espectroscopia: lactato/creatina, glutamato-glutamina/creatina, colina/creatina, colina/lipídio, 4,0-4,3 ppm/creatina e lipídio/creatina. Resultados: Dos 97 pacientes avaliados, 69 foram diagnosticados como adenomas e 28 foram diagnosticados como não adenomas. Todas as medições SII e razões de metabólitos derivados da espectroscopia foram significativas para a diferenciação entre adenomas e não adenomas, exceto as razões lipídio/creatina e colina/lipídio. Em 37,8% dos casos não foi possível realizar espectroscopia. Quando possível, a razão lactato/creatina apresentou maior precisão do que o SII. Conclusão: A determinação das razões SII e metabólitos aumentaram a acurácia do diagnóstico diferencial de adenomas adrenais.
RESUMO
Acute pancreatitis (AP) is a common adverse event (AE) of endoscopic papillectomy (EP). Prophylactic plastic pancreatic stent (PPS) placement appears to prevent AP. We evaluated factors associated with post-EP AP by a retrospective analysis of patients with tumors of the duodenal papilla who underwent EP from January 2008 to November 2016 at 2 tertiary care centers. Clinical, laboratory, endoscopic ultrasound parameters, and PPS placement were evaluated. Seventy-two patients underwent EP (37 men), with mean age of 60.3 (31-88) years. Mean main pancreatic duct (MPD) diameter was 0.44 (0.18-1.8) cm. Mean tumor size was 1.8 (0.5-9.6) cm. Tumors were staged as uT1N0, uT2N0, and uT1N1 in 87.5%, 11.1%, and 1.4%. Thirty-eight AEs occurred in 33 (45.8%) patients, with no mortality. Total bilirubin, tumor size, MPD diameter, and PPS placement had odds ratios (ORs) of 0.82, 0.14, 0.00, and 6.43 for AP. Multivariate analysis (PPS placement × MPD diameter) showed ORs of 4.62 (95%CI, 1.03-21.32; p = 0.049) and 0.000 (95%CI, 0.00-0.74; p = 0.042) for AP. In conclusion, patients with jaundice, large tumors, and dilated MPD seem less likely to have post-EP AP. PPS placement was associated with a higher risk of AP, which may question its use.
Assuntos
Pancreatite/etiologia , Procedimentos Cirúrgicos Profiláticos/efeitos adversos , Esfinterotomia Endoscópica/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias do Ducto Colédoco/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos Retrospectivos , Fatores de RiscoRESUMO
BACKGROUND: Intraductal papillary mucinous tumor (IPMN) are being diagnosed with increasing frequency. Computerized tomography scanning is commonly used as the primary imaging modality before surgery nonetheless magnetic resonance cholangiopancreatography (MRCP) provides better characterization. Endosonography-guided fine needle aspiration (EUS-FNA) has emerged as a way to reach pathological diagnose. AIM: To compare results of both methods with surgical pathology findings for classification of IPMN. METHODS: Thirty-six patients submitted to surgical resection with preoperative suspect of IPMN were submitted preoperatively to MRCP and EUS-FNA. Images obtained were analyzed according to a classification determined for each method. ROC curve was used for statistical analysis, that compared the images tests with the purpose of finding the best method for diagnosis and classification of IPMN. RESULTS: Sixteen patients underwent pancreatoduodenectomy, 16 to subtotal pancreatectomy and only four laparotomy. Pathological diagnosis was IPMN (n=33) and pancreatic intraepithelial neoplasia type 2 (n=3). Twenty-nine revealed non-invasive neoplasia and invasive form in four patients. MRCP and EUS-FNA have correctly diagnosed and classified (type of IPMN), in 62.5% and 83.3% (p=0.811), the affected segment location in 69% and 92% (p=0.638) and identification of nodules and/or vegetation presence in 45% and 90% (p=0.5). Regarding to histopathological diagnosis by EUS-FNA the sensitivity was 83.3%; specificity was 100%; positive predictive value was 100%; negative predictive value was 33.3% and accuracy was 91.7%. CONCLUSIONS: There was no significant difference in the diagnosis of IPMN. However, EUS-FNA showed better absolute results than MRCP to identify nodule and/or vegetation.
Assuntos
Neoplasias Intraductais Pancreáticas/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Colangiopancreatografia por Ressonância Magnética , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto JovemRESUMO
OBJECTIVE: To evaluate the computed tomography characteristics of patients admitted with clinical suspicion of acute adrenal hemorrhage at three centers over a 3-year period and in whom that diagnosis was ultimately confirmed. MATERIALS AND METHODS: This was a retrospective analysis of computed tomography findings in patients with suspected acute adrenal hemorrhage. We included only those cases in which the diagnosis was confirmed. Patients with aortic rupture and retroperitoneal hemorrhage were excluded. The images were analyzed by an experienced radiologist and by two radiology residents. RESULTS: Six cases of unilateral adrenal hemorrhage (three on the left and three on the right) were analyzed. On computed tomography, each appeared as a rounded, oval mass altering the usual anatomy of the adrenal gland. The maximum diameter was 12.2 cm, and attenuation ranged from 45 to 70 HU. There was no appreciable contrast enhancement. No calcifications were observed. CONCLUSION: Adrenal hemorrhage, albeit rare, is potentially fatal. Early diagnosis is essential. Therefore, recognition of the possible presentations of these lesions by radiologists may help prevent hemorrhage from progressing to adrenal insufficiency and death.
OBJETIVO: Avaliar as características de imagem na tomografia computadorizada de pacientes admitidos com suspeita clínica de hemorragia adrenal aguda em três instituições, no período de três anos, e que tiveram o diagnóstico final confirmado. MATERIAIS E MÉTODOS: Análise retrospectiva da tomografia computadorizada de pacientes com suspeita de hemorragia adrenal aguda. Foram incluídos apenas os casos com confirmação diagnóstica. Foram excluídos os pacientes que apresentaram ruptura aórtica e hemorragia retroperitonial. As imagens foram analisadas por um radiologista experiente e dois residentes em radiologia. RESULTADOS: Este estudo analisou seis casos de hemorragia adrenal unilateral, três deles na adrenal esquerda e três na adrenal direita. Todos apresentaram-se com massa arredondada ou oval, alterando a anatomia habitual da glândula. O diâmetro máximo foi 12,2 cm e os valores de atenuação variaram de 45 a 70 UH, não se observando realce nas fases contrastadas. Não foram observadas calcificações. CONCLUSÃO: As hemorragias adrenais são raras, porém, potencialmente fatais. O diagnóstico precoce é essencial, portanto, o reconhecimento das possíveis apresentações dessas lesões pelos radiologistas pode ajudar a evitar que pacientes evoluam com insuficiência da glândula e óbito.
RESUMO
Abstract Objective: To evaluate the computed tomography characteristics of patients admitted with clinical suspicion of acute adrenal hemorrhage at three centers over a 3-year period and in whom that diagnosis was ultimately confirmed. Materials and Methods: This was a retrospective analysis of computed tomography findings in patients with suspected acute adrenal hemorrhage. We included only those cases in which the diagnosis was confirmed. Patients with aortic rupture and retroperitoneal hemorrhage were excluded. The images were analyzed by an experienced radiologist and by two radiology residents. Results: Six cases of unilateral adrenal hemorrhage (three on the left and three on the right) were analyzed. On computed tomography, each appeared as a rounded, oval mass altering the usual anatomy of the adrenal gland. The maximum diameter was 12.2 cm, and attenuation ranged from 45 to 70 HU. There was no appreciable contrast enhancement. No calcifications were observed. Conclusion: Adrenal hemorrhage, albeit rare, is potentially fatal. Early diagnosis is essential. Therefore, recognition of the possible presentations of these lesions by radiologists may help prevent hemorrhage from progressing to adrenal insufficiency and death.
Resumo Objetivo: Avaliar as características de imagem na tomografia computadorizada de pacientes admitidos com suspeita clínica de hemorragia adrenal aguda em três instituições, no período de três anos, e que tiveram o diagnóstico final confirmado. Materiais e Métodos: Análise retrospectiva da tomografia computadorizada de pacientes com suspeita de hemorragia adrenal aguda. Foram incluídos apenas os casos com confirmação diagnóstica. Foram excluídos os pacientes que apresentaram ruptura aórtica e hemorragia retroperitonial. As imagens foram analisadas por um radiologista experiente e dois residentes em radiologia. Resultados: Este estudo analisou seis casos de hemorragia adrenal unilateral, três deles na adrenal esquerda e três na adrenal direita. Todos apresentaram-se com massa arredondada ou oval, alterando a anatomia habitual da glândula. O diâmetro máximo foi 12,2 cm e os valores de atenuação variaram de 45 a 70 UH, não se observando realce nas fases contrastadas. Não foram observadas calcificações. Conclusão: As hemorragias adrenais são raras, porém, potencialmente fatais. O diagnóstico precoce é essencial, portanto, o reconhecimento das possíveis apresentações dessas lesões pelos radiologistas pode ajudar a evitar que pacientes evoluam com insuficiência da glândula e óbito.
RESUMO
PURPOSE: To assess uterine contractility using ultrafast magnetic resonance imaging (cine MRI) before and after uterine fibroid embolization (UFE). MATERIALS AND METHODS: This is a prospective study of uterine contractility in 26 patients (age 30-41 years) undergoing UFE for symptomatic uterine fibroids. Cine MRI was performed before and 6 months after UFE. Two radiologists evaluated uterine contractility and classified it as absent, ordered, or disordered. Patients were then grouped into three distinct patterns of progression: unchanged contractility (group A), modified contractility (B), and loss of contractility (C). These findings were then confronted with factors that might have interfered with uterine contractility pattern (uterine volume, location of dominant fibroid, fibroid/myometrium index, and fibroid necrosis pattern). RESULTS: Of the 26 patients, 8 (30.7%) had no contractility before the procedure, while 18 (69.2%) exhibited some form of contractility (11 [61%] ordered, 7 [39%] disordered). All 8 patients who had no contractility at baseline exhibited contractility after UFE (5 ordered, 3 disordered). Of the 11 who had ordered contractility at baseline, 9 remained ordered and 2 lost contractility after UFE. Of the 7 with disordered contractility at baseline, 1 remained disordered, 5 progressed to ordered contractility, and 1 lost contractility. Overall, 10 patients (38%) had no change in contractility after UFE (group A), 13 (50%) had a positive change (group B), and 3 (11%) lost contractility (group C). The potential interference factors assessed had no statistically significant effect in any group. CONCLUSION: In women of reproductive age with symptomatic fibroids, uterine contractility improved significantly after UFE. LEVEL OF EVIDENCE: Level 3-non-randomized controlled cohort/follow-up study.