Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Tex Heart Inst J ; 44(6): 416-419, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29276443

RESUMO

Aneurysm of the sinus of Valsalva, a rare cardiac condition, results from dilation of an aortic sinus. Sudden aneurysm rupture can trigger rapidly progressive heart failure. We discuss the case of a 57-year-old woman with situs ambiguus, isolated levocardia, and polysplenia who presented with acute-onset heart failure. Transesophageal echocardiograms revealed an aneurysm of the right coronary sinus of Valsalva that had ruptured into the right atrial cavity. The patient underwent successful surgical repair. To our knowledge, this is the first report of a sinus of Valsalva aneurysm in a patient with this combination of congenital abnormalities. We briefly review the association between congenital heart disease, situs ambiguus, and ciliary dysfunction.


Assuntos
Anormalidades Múltiplas , Ruptura Aórtica/etiologia , Síndrome de Heterotaxia/complicações , Levocardia/complicações , Seio Aórtico , Baço/anormalidades , Esplenopatias/complicações , Ruptura Aórtica/diagnóstico , Ecocardiografia Transesofagiana , Feminino , Humanos , Levocardia/diagnóstico , Pessoa de Meia-Idade , Baço/diagnóstico por imagem , Esplenopatias/congênito , Esplenopatias/diagnóstico , Tomografia Computadorizada por Raios X
2.
J Vasc Interv Radiol ; 25(12): 1929-35, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25311968

RESUMO

PURPOSE: Computed tomography (CT)-guided core needle biopsy (CNB) can be affected by streak artifact obscuring the needle tip. This study investigates factors that influence the occurrence and severity of streak artifact during CNB. MATERIALS AND METHODS: Eight coaxial guide needles of two sizes from two manufacturers with and without stylets were imaged in a CT phantom, with CT reconstructed with adaptive statistical iterative reconstruction and filtered back projection. CNB-related streak artifact was quantified with profile analysis in an image-processing program. Differences between maximum attenuation at the needle tip and minimum attenuation in the streak artifact were compared for each variable. Diagnostic acceptability and streak artifact were subjectively assessed on each phantom image and on 40 clinical CNB procedures by three independent blinded reviewers following training case review. RESULTS: Artifact was significantly less with the central stylet removed versus in situ (median, 1,145 HU vs 3,390 HU; P < .001) for all needles, and less for 19-gauge needles versus 17-gauge needles (median, 1,334 HU vs 2,780 HU, respectively; P = .006). There were no differences based on manufacturer (P = .906) or reconstruction algorithm (P = .524). Independent reviews found that streak artifact was significantly reduced when the central stylet was removed (κ = 0.875-1.0; P < .001), and needle tip position was better in cases in which the stylet was removed (κ = 0.231-0.711; P < .001). CONCLUSIONS: Streak artifact can be reduced and needle tip visualization improved by confirming final biopsy needle position with the central stylet removed on CT and using smaller-gauge guide needles.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Biópsia com Agulha de Grande Calibre/instrumentação , Biópsia com Agulha de Grande Calibre/métodos , Biópsia por Agulha , Biópsia Guiada por Imagem/instrumentação , Biópsia Guiada por Imagem/métodos , Variações Dependentes do Observador , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA