Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orthod ; 36(3): 145-51, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19741175

RESUMO

OBJECTIVE: To compare the effects of four different asymmetric headgear systems. DESIGN: A mathematical method for three-dimensional data called finite element analysis. SETTING: The Orthodontic Department, the Federal University of Rio de Janeiro and the Metallurgical Engineering Department of the Fluminense Federal University. METHODS: Four systems of delivering an asymmetrical force to headgear were studied: using face-bow arms of different lengths, a symmetric face-bow with one of the arms bent outward in relation to the internal arch, a symmetric face-bow used in combination with a transpalatal arch activated to produce an asymmetric force, and a symmetric face-bow with the outer bow soldered to the inner bow on the side where a larger force will be applied. RESULTS: All four systems were effective in promoting asymmetric distal movement of the molars. However, the symmetrical face-bow with the outer bow soldered to the inner bow (system 4) could be used in asymmetric mechanics if the bows are soldered on the opposite side to the proposed distalization. Lateral and occlusal displacing forces were observed in all systems as well as tip-back and rotational movements. CONCLUSION: The simulated computer model used in this investigation suggests that a face-bow with a symmetrically soldered joint and arms of equal lengths used in combination with a transpalatal arch is the best headgear option when asymmetric movement of upper molars is desired.


Assuntos
Aparelhos de Tração Extrabucal , Má Oclusão Classe II de Angle/terapia , Desenho de Aparelho Ortodôntico , Técnicas de Movimentação Dentária/instrumentação , Simulação por Computador , Análise do Estresse Dentário , Análise de Elementos Finitos , Lateralidade Funcional , Humanos , Dente Molar , Estresse Mecânico
2.
Angle Orthod ; 77(5): 890-3, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17685763

RESUMO

OBJECTIVES: To evaluate in vitro the surface of elastomeric chains of different manufacturers to verify the presence of pathogenic microorganisms at the moment of unpacking and analyze a possible inhibitory effect of the elastomeric chain when exposed to microorganisms of the oral cavity, for example, Streptococcus mutans, Lactobacillus casei, and Candida albicans. MATERIALS AND METHODS: Elastomeric chains from Ortho-Organizers Inc, 3M Unitek, and Dental Morelli were placed in petri plates with brain heart infusion agar medium and in sterile test tubes with brain heart infusion broth. The samples were incubated at 37 degrees C and analyzed at 24 hours, 48 hours, 3 days, and 7 days. In addition, elastomeric chains from the three manufacturers were placed in dishes, inoculated with microorganisms, incubated at 37 degrees C, and analyzed after 24 and 72 hours. RESULTS: No microorganism growth was detected after all incubation periods. No inhibition zones were identified surrounding the elastomeric chain. CONCLUSIONS: The results suggest that the fabrication of elastomeric chain is in accordance with biohazard concepts. However, careful manipulation is necessary to avoid colonization of pathogenic microorganisms since the composition of the elastomeric chains analyzed do not include antimicrobial agents.


Assuntos
Elastômeros/química , Aparelhos Ortodônticos/microbiologia , Ortodontia Corretiva/instrumentação , Candida albicans/isolamento & purificação , Contaminação de Equipamentos/prevenção & controle , Lacticaseibacillus casei/isolamento & purificação , Streptococcus mutans/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...