Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38844072

RESUMO

INTRODUCTION AND OBJECTIVES: There is limited evidence to identify the most accurate method for measuring the mitral valve area (MVA) after percutaneous edge-to-edge mitral repair. Our objective was to evaluate the optimal method in this context and its correlation with the mean transmitral gradient. METHODS: A registry of patients undergoing percutaneous mitral repair was conducted, analyzing different methods of measuring MVA and their correlation with the mean gradient. RESULTS: We analyzed data from 167 patients. The mean age was 76±10.3 years, 54% were men, and 46% were women. Etiology was degenerative in 45%, functional in 39%, and mixed in 16%. Postclip MVA measurements were 1.89±0.60 cm2 using pressure half-time (PHT), 2.87±0.83 cm2 using 3D planimetry, and the mean gradient was 3±1.19mmHg. MVA using 3D planimetry showed a stronger correlation with the mean gradient (r=0.46, P<.001) than MVA obtained by PHT (r=0.19, P=.048). Interobserver agreement was also higher with 3D planimetry than with PHT (intraclass correlation coefficient of 0.90 vs 0.81 and variation coefficient of 9.6 vs 19.7%, respectively). CONCLUSIONS: Our study demonstrates that the PHT method significantly underestimates MVA after clip implantation compared with direct measurement using transesophageal 3D planimetry. The latter method also correlates better with postimplantation gradients and has less interobserver variability. These results suggest that 3D planimetry is a more appropriate method for assessing postclip mitral stenosis.

2.
J Clin Med ; 12(23)2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38068420

RESUMO

In current clinical practice, commissural alignment of the transcatheter heart valve (THV) during transcatheter aortic valve implantation (TAVI) is seldom achieved. Orientation of the THV within the aortic root and the subsequent influence upon leaflet haemodynamic function, coronary blood flow, and ease of access to the coronary ostia are gaining significant interest. Herein, we review the incidence and clinical implications of commissural misalignment in TAVI and offer thorough descriptions of how optimal alignment can be achieved with several different contemporary THV devices.

3.
J Clin Med ; 12(24)2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38137816

RESUMO

This review article describes in depth the current usefulness of transesophageal echocardiography in patients who undergo transcatheter aortic valve replacement. Pre-intervention, 3D-transesophageal echocardiography allows us to accurately evaluate the aortic valve morphology and to measure the valve annulus, helping us to choose the appropriate size of the prosthesis, especially useful in cases where the computed tomography is not of adequate quality. Although it is not currently used routinely during the intervention, it remains essential in those cases of greater complexity, such as for patients with greater calcification and bicuspid valve, mechanical mitral prosthesis, and "valve in valve" procedures. Three-dimensional transesophageal echocardiography is the best technique to detect and quantify paravalvular regurgitation, a fundamental aspect to decide whether immediate valve postdilation is needed. It also allows to detect early any immediate complications such as cardiac tamponade, aortic hematoma or dissection, migration of the prosthesis, malfunction of the prosthetic leaflets, or the appearance of segmental contractility disorders due to compromise of the coronary arteries ostium. Transesophageal echocardiography is also very useful in follow-up, to check the proper functioning of the prosthesis and to rule out complications such as thrombosis of the leaflets, endocarditis, or prosthetic degeneration.

4.
J Clin Med ; 11(9)2022 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-35566402

RESUMO

Background: There is no consensus on the best intraprocedural parameter to evaluate residual mitral regurgitation (MR) after transcatheter edge-to-edge mitral repair (TEER). Thus, our aim was to evaluate the predictive value of different MR parameters from intraprocedural transesophageal echocardiogram (TEE) for grading in consecutive transthoracic echocardiogram (TTE) during the follow up. Methods: All the consecutive patients who underwent TEER with MitraClip between 2010 and 2020 in our center were considered. TEE-derived immediate postprocedural MR parameters were reassessed to blindly compare them with follow up MR grading in sequential TTE. Results: We finally included 88 patients (64.8% males; 76 ± 10 years-old). Significant MR was detected in 14.3% of the cases at 6 months, in similar proportion than at postprocedural at 1 month. Among all the intraprocedural TEE quantitative parameters only additive and maximum VC were associated with significant MR persistence. Moreover, on ROC analysis maximum VC demonstrated an excellent discriminatory power (AUC 0.96; p < 0.001) to identify MR ≥ III at 6 months. Thus, a cut-off point of 0.45 cm demonstrated 88% sensitivity and 89% specificity. Conclusion: Among intraprocedural TEE parameters to evaluate residual MR in TEER, maximum and additive VC were the most reliable to predict persistence of significant insufficiency.

5.
Rev Esp Cardiol (Engl Ed) ; 74(2): 159-166, 2021 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32198007

RESUMO

INTRODUCTION AND OBJECTIVES: Myocardial strain analysis could provide additional information to left ventricular ejection fraction (LVEF) in nonischemic dilated cardiomyopathy (NIDC). Our aim was to analyze the feasibility of left ventricular strain evaluation using cardiac magnetic resonance feature tracking (FT) in NIDC, and to determine its clinical and prognostic impact. METHODS: We retrospectively included consecutive patients with NIDC who underwent cardiac magnetic resonance. Left ventricular global longitudinal, circumferential and radial strain were obtained from standard cine sequences using FT analysis software. We evaluated their association with a composite endpoint (heart failure, implantable cardioverter-defibrillator in secondary prevention, or death). RESULTS: FT analysis could be performed in all of the 98 patients (mean age 68±13 years, 72% men). Intra- and interobserver concordance was good for global longitudinal and circumferential strain but was worse for radial strain. Global circumferential strain was independently associated (OR, 1.16; P=.045) with LVEF normalization during follow-up and was the only morphological parameter independently associated with the composite endpoint (OR, 1.15; P=.038). A cutoff value <-8.2% was able to predict the incidence of this event during follow-up (log-rank 4.6; P=.032). CONCLUSIONS: Left ventricular strain analysis with FT is feasible and reproducible in NIDC. Global circumferential strain was able to predict LVEF recovery and the appearance of major cardiovascular events during follow-up.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico , Estudos de Viabilidade , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos
6.
Atherosclerosis ; 317: 52-58, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33261814

RESUMO

BACKGROUND AND AIMS: Heterozygous familial hypercholesterolemia (FH) is associated with premature atherosclerotic cardiovascular disease. Semi-automated plaque characterization (SAPC) by coronary computed tomographic angiography (CTA) provides information regarding coronary plaque burden and plaque characterization. Our aim was to quantify and characterize the coronary plaque burden of patients with FH using SAPC analysis and to identify which factors are related to plaque burden and plaque characteristics. A second aim was to analyse the prognostic implications of these parameters. METHODS: Two hundred and fifty-nine asymptomatic individuals with molecularly determined FH were enrolled in this follow-up cohort study and underwent a coronary CTA analysed with SAPC. RESULTS: Mean follow-up time after coronary CTA was 3.9 ± 2 years. Mean age was 46.9 (10.7) years (130 women, 50.2%). Median plaque burden was 25.0% (19.0-29.0), non-calcified plaque burden 22.83% (17.94-26.88), calcified plaque-burden 1.12% (0.31-2.86) and CCS 8.9 (0-93). Five-year risk was independently related to plaque burden, non-calcified plaque burden, calcified plaque burden and coronary calcium score (B:3.75, 95%CI:2.92-4.58; p < 0.001, B:2.9, 95%CI:2.15-3.66; p < 0.001, B:0.75, 95%CI 0.4-1.1; p < 0.001 and B:82.2, 95%CI:49.28-115.16; p < 0.001 respectively). During follow-up, there were 15 (5.81%) nonfatal events and 1 (0.4%) fatal event. Plaque burden was significantly related to event-free survival during follow-up (HR:1.11; 95%CI:1.05-1.18; p < 0.001). CONCLUSIONS: Coronary atherosclerosis and its qualitative components may be quantified by means of SAPC in patients with FH. Plaque burden, calcified plaque burden and non-calcified plaque burden were independently related to the estimated cardiovascular risk. Plaque burden was also related to prognosis.


Assuntos
Doença da Artéria Coronariana , Hiperlipoproteinemia Tipo II , Placa Aterosclerótica , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Hiperlipoproteinemia Tipo II/complicações , Hiperlipoproteinemia Tipo II/diagnóstico por imagem , Hiperlipoproteinemia Tipo II/genética , Pessoa de Meia-Idade , Prognóstico , Fatores de Risco
7.
Rev Esp Cardiol (Engl Ed) ; 74(1): 81-89, 2021 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33008773

RESUMO

Technological progress in medicine is constantly garnering pace, requiring that physicians constantly update their knowledge. The new wave of technologies breaking through into clinical practice includes the following: a) mHealth, which allows constant monitoring of biological parameters, anytime, anyplace, of hundreds of patients at the same time; b) artificial intelligence, which, powered by new deep learning techniques, are starting to beat human experts at their own game: diagnosis by imaging or electrocardiography; c) 3-dimensional printing, which may lead to patient-specific prostheses; d) systems medicine, which has arisen from big data, and which will open the way to personalized medicine by bringing together genetic, epigenetic, environmental, clinical and social data into complex integral mathematical models to design highly personalized therapies. This state-of-the-art review aims to summarize in a single document the most recent and most important technological trends that are being applied to cardiology, and to provide an overall view that will allow readers to discern at a glance the direction of cardiology in the next few years.


Assuntos
Big Data , Cardiologistas , Cardiologia , Inteligência Artificial , Diagnóstico por Imagem , Humanos
8.
JACC Case Rep ; 2(11): 1702-1707, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34317039

RESUMO

Some coronary artery anomalies are associated with increased risk of sudden cardiac death and myocardial infarction in young patients. There are few data on the clinical and prognostic relevance of isolated origin of the left circumflex artery from the pulmonary artery, an extraordinarily rare variant of anomalous left coronary artery from the pulmonary artery. (Level of Difficulty: Intermediate.).

9.
Rev chil anest ; 49(3): 397-400, 2020.
Artigo em Espanhol | LILACS | ID: biblio-1510853

RESUMO

The coronavirus pandemic has generated a serious global health problem. COVID-19 mainly affects the lung, but it has been seen that myocardial involvement also occurs in some patients, producing myocarditis and arrhythmias.


La pandemia por coronavirus ha generado un grave problema sanitario mundial. El COVID-19 afecta fundamentalmente el pulmón, pero se ha visto que en algunos pacientes también se produce afectación del miocardio produciendo miocarditis y arritmias.


Assuntos
Humanos , COVID-19/complicações , Cardiopatias/etiologia , Arritmias Cardíacas/etiologia , Cardiopatias/fisiopatologia , Miocardite/etiologia
10.
World J Cardiol ; 11(10): 217-220, 2019 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-31754409

RESUMO

Social media has changed the way we learn, educate, and interact with our peers. The dynamic nature of social media and their immediate availability through our portable devices (smartphones, tablets, smartwatches, etc.) is quickly transforming the way we participate in society. The scope of these digital tools is broad as they deal with many different aspects: Teaching and learning, case discussion, congresses coverage, peer to peer interaction, research are examples worth mentioning. The scientific societies considered more innovative, are promoting these tools between their members. These new concepts need to be known by the cardiologists to stay updated, as countless information is moving rapidly through these channels. We summarize the main reasons why learning how to use these tools to be part of the conversation is essential for the cardiologist in training or fully stablished.

11.
Rev. esp. cardiol. (Ed. impr.) ; 72(9): 732-739, sept. 2019. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-189132

RESUMO

Introducción y objetivos: El desarrollo tardío de insuficiencia tricúspide funcional tras cirugía valvular izquierda de origen reumático es un importante predictor de mal pronóstico. Este estudio investiga la utilidad y precisión diagnóstica del área tricúspide evaluada por ecocardiografía transtorácica tridimensional en comparación con el diámetro bidimensional (D2D) convencional para evaluar la dilatación significativa del anillo tricúspide, proporcionando puntos de corte que podrían utilizarse en la práctica clínica para mejorar la selección de pacientes para cirugía. Métodos: Se incluyeron prospectivamente 109 pacientes con valvulopatía reumática en ausencia de reemplazo valvular previo. La insuficiencia tricúspide se dividió en tres grupos: leve, moderado y grave. Se obtuvieron los puntos de corte óptimos del área tridimensional (A3D) y del D2D para la identificación de la dilatación significativa del anillo tricúspide y se compararon con los umbrales de las guías actuales. También se evaluaron los factores predictivos de la dilatación del A3D. Resultados: Se identificaron los puntos de corte óptimos, absolutos y ajustados por el área de superficie corporal (ASC), de ambos parámetros (A3D: 10,4 cm2, 6,5 cm2/m2, D2D: 35 mm, 21 mm/m2) siendo el parámetro A3D/ASC el que obtuvo el mejor rendimiento diagnóstico (ABC=0,83). El área tricúspide por ecocardiografía transtorácica tridimensional ayudó a reclasificar la indicación quirúrgica en el 14% de pacientes con insuficiencia tricúspide leve (IC95%, 1-15%; p=0,03) y en el 37% con insuficiencia tricúspide moderada (IC95%, 22-37%; p<0,0001), mientras que el A3D/ASC cambió los criterios de cirugía en los casos de insuficiencia tricúspide leve (17%, IC95%, 3-17%; p=0,01) en comparación con el D2D/ASC. En el análisis multivariable, los volúmenes de la aurícula derecha e izquierda y el diámetro del ventrículo derecho basal se correlacionaron independientemente con el A3D. Conclusiones: El umbral del D2D actual propuesto de 40 mm infraestima la dilatación del anillo tricúspide. Aunque 21 mm/m2 podría ser un criterio de selección razonable, la combinación con la evaluación del A3D mejora la selección de pacientes candidatos para cirugía


Introduction and objectives: Late functional tricuspid regurgitation after rheumatic left-sided valve surgery is an important predictor of poor prognosis. This study investigated the usefulness and accuracy of 3-dimensional transthoracic echocardiography tricuspid area compared with conventional 2-dimensional diameter (2DD) for assessing significant tricuspid annulus dilatation, providing cutoff values that could be used in clinical practice to improve patient selection for surgery. Methods: We prospectively included 109 patients with rheumatic heart disease in the absence of previous valve replacement. Tricuspid regurgitation was divided into 3 groups: mild, moderate, and severe. Optimal 3-dimensional area (3DA) and 2DD cutoff points for identification of significant tricuspid annulus dilatation were obtained and compared with current guideline thresholds. Predictive factors for 3DA dilatation were also assessed. Results: Optimal cutoff points for both absolute and adjusted to body surface area (BSA) tricuspid annulus dilatation were identified (3DA: 10.4 cm2, 6.5 cm2/m2; 2DD: 35 mm, 21 mm/m2); 3DA/BSA had the best diagnostic performance (AUC=0.83). Three-dimensional transthoracic echocardiography tricuspid area helped to reclassify surgical indication in 14% of patients with mild tricuspid regurgitation (95%CI, 1%-15%; P=.03) and 37% with moderate tricuspid regurgitation (95%CI, 22%-37%; P<.0001), whereas 3DA/BSA changed surgery criteria in cases of mild tricuspid regurgitation (17%; 95%CI, 3%-17%; P=.01) compared with 2DD/BSA. On multivariable analysis, right and left atrial volumes and basal right ventricle diameter were independently correlated with 3DA. Conclusions: The current 40 mm threshold underestimates tricuspid annulus dilatation. Although 21 mm/m2 seems to be a reasonable criterion, the combination with 3DA assessment improves patient selection for surgery


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Anuloplastia da Valva Cardíaca/métodos , Cardiopatia Reumática/complicações , Ecocardiografia Tridimensional/métodos , Anel Vascular/diagnóstico por imagem , Seleção de Pacientes , Estudos Prospectivos , Sensibilidade e Especificidade
12.
Rev Esp Cardiol (Engl Ed) ; 72(9): 732-739, 2019 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30042008

RESUMO

INTRODUCTION AND OBJECTIVES: Late functional tricuspid regurgitation after rheumatic left-sided valve surgery is an important predictor of poor prognosis. This study investigated the usefulness and accuracy of 3-dimensional transthoracic echocardiography tricuspid area compared with conventional 2-dimensional diameter (2DD) for assessing significant tricuspid annulus dilatation, providing cutoff values that could be used in clinical practice to improve patient selection for surgery. METHODS: We prospectively included 109 patients with rheumatic heart disease in the absence of previous valve replacement. Tricuspid regurgitation was divided into 3 groups: mild, moderate, and severe. Optimal 3-dimensional area (3DA) and 2DD cutoff points for identification of significant tricuspid annulus dilatation were obtained and compared with current guideline thresholds. Predictive factors for 3DA dilatation were also assessed. RESULTS: Optimal cutoff points for both absolute and adjusted to body surface area (BSA) tricuspid annulus dilatation were identified (3DA: 10.4 cm2, 6.5 cm2/m2; 2DD: 35 mm, 21 mm/m2); 3DA/BSA had the best diagnostic performance (AUC=0.83). Three-dimensional transthoracic echocardiography tricuspid area helped to reclassify surgical indication in 14% of patients with mild tricuspid regurgitation (95%CI, 1%-15%; P=.03) and 37% with moderate tricuspid regurgitation (95%CI, 22%-37%; P<.0001), whereas 3DA/BSA changed surgery criteria in cases of mild tricuspid regurgitation (17%; 95%CI, 3%-17%; P=.01) compared with 2DD/BSA. On multivariable analysis, right and left atrial volumes and basal right ventricle diameter were independently correlated with 3DA. CONCLUSIONS: The current 40 mm threshold underestimates tricuspid annulus dilatation. Although 21 mm/m2 seems to be a reasonable criterion, the combination with 3DA assessment improves patient selection for surgery.


Assuntos
Anuloplastia da Valva Cardíaca/métodos , Ecocardiografia Tridimensional/métodos , Seleção de Pacientes , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico
13.
Rev. esp. cardiol. (Ed. impr.) ; 71(9): 735-742, sept. 2018. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-178779

RESUMO

Introducción y objetivos: Las válvulas SAPIEN 3 (S3) y Medtronic Evolut R (EVR) son prótesis transcatéter de segunda generación, diseñadas para reducir el grado de insuficiencia aórtica (IAo) paravalvular. El objetivo es comparar la hemodinámica valvular en un estudio de casos emparejados con análisis ecocardiográfico independiente. Métodos: De una población de 201 pacientes tratados con implante percutáneo de válvula aórtica, se emparejó a un total de 144 (S3, n = 80; EVR, n = 64) en función del diámetro del anillo y de la puntuación de calcio aórtico medidos por tomografía computarizada. Los ecocardiogramas de seguimiento basal, al mes y a los 6 meses se analizaron de manera independiente y centralizada. Resultados: No se observaron diferencias respecto a las características basales clínicas y ecocardiográficas. La prótesis EVR mostró un mejor perfil hemodinámico evaluado mediante gradiente aórtico máximo (EVR frente a S3, 13 ± 7 frente a 20 ± 10; p < 0,001), gradiente aórtico medio (7 ± 3 frente a 11 ± 6; p < 0,001) e índice de velocidad Doppler (0,65 ± 0,15 frente a 0,51 ± 0,16; p < 0,001). Por otro lado, la tasa de IAo paravalvular moderada-grave o de cualquier grado de IAo paravalvular (≥ leve) fue mayor en el grupo de EVR (el 11 y el 50%) que en el de S3 (el 2,5 y el 21%; p < 0,05), con mayor número de chorros regurgitantes (p < 0,001). Conclusiones: En una cohorte de casos emparejados tratados con implante percutáneo de válvula aórtica de segunda generación, la S3 se asoció con una menor tasa de IAo paravalvular y mayor gradiente transprotésico residual que con la EVR


Introduction and objectives: The SAPIEN 3 (S3) valve and the Medtronic Evolut R (EVR) are second-generation transcatheter valves, designed to further reduce the rate of paravalvular aortic regurgitation (AoR). The aim of this study was to compare the 2 devices in terms of valve performance in a case-matched study with independent echocardiographic analysis. Methods: Of a population of 201 patients who underwent transcatheter aortic valve implantation, 144 patients (S3, n = 80; EVR, n = 64) were matched according to aortic annulus diameter and aortic valve calcium score, as assessed by computed tomography. All echocardiographic examinations collected at baseline and at 1- and 6-month follow-up were centrally analyzed. Results: The 2 groups were well balanced in baseline clinical and echocardiographic characteristics. The EVR valve showed a better hemodynamic profile as assessed by peak aortic gradient (EVR 13 ± 7 vs S3 20 ± 10 mmHg; P < .001), mean aortic gradient (EVR 7 ± 3 vs S3 11 ± 6 mmHg; P < .001), and Doppler velocity index (EVR 0.65 ± 0.15 vs S3 0.51 ± 0.16; P < .001). The rate of moderate-severe or any paravalvular (≥ mild) AoR was higher in the EVR group (11% and 50%) than in the S3 group (2.5% and 21%; P < .05, respectively), with a larger number of paravalvular jets (P < .001). Conclusions: In a case-matched cohort of transcatheter aortic valve implantation patients, the S3 valve was associated with a lower rate of paravalvular AoR but also with a higher residual gradient than the EVR system


Assuntos
Humanos , Masculino , Feminino , Hemodinâmica/fisiologia , Stents Metálicos Autoexpansíveis , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/cirurgia , Estudos de Casos e Controles , Próteses Valvulares Cardíacas/classificação , Implante de Prótese de Valva Cardíaca/classificação
14.
Circ J ; 82(11): 2880-2886, 2018 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-30135324

RESUMO

BACKGROUND: Prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) remains an important issue. The aim of this study was to assess the value of a new discongruence index, to predict PPM after TAVR.Methods and Results: A total of 185 patients with severe aortic stenosis who underwent TAVR with the Edwards Sapien prosthesis or CoreValve Revalving system were included (Edwards valve, n=119; Core Valve Revalving system, n=66). Discongruence index was calculated pre-procedurally as the ratio of selected transcatheter valve size (mm) to body surface area (cm2). PPM was defined as effective orifice area (EOA) ≤0.85 cm2/m2 on transthoracic echocardiography before hospital discharge. Mean age was 82±5 years and 72 patients (38.9%) were men. The overall incidence of post-TAVR PPM was 35.1% (n=65). Discongruence index correlated with post-TAVR indexed EOA (y=0.18+0.057x; P<0.001). On multivariate logistic regression analysis, discongruence index was the only independent predictor of post-TAVR PPM (OR, 0.15; 95% CI: 0.03-0.66; P=0.012), and the area under the receiver operating characteristic curve was 0.62 (95% CI: 0.54-0.70, P=0.003), with an optimal cut-off point of 15.02 (sensitivity, 86.2%; specificity, 72.5%; positive predictive value, 74.3%; negative predictive value, 83.4%). CONCLUSIONS: The new discongruence index may be useful tool to predict PPM after TAVR.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
15.
J Clin Lipidol ; 12(4): 948-957, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29753733

RESUMO

BACKGROUND: Familial hypercholesterolemia (FH) confers an increased risk of premature atherosclerotic disease. Coronary computed tomographic angiography (CTA) can assess preclinical coronary atherosclerosis. OBJECTIVES: To describe coronary CTA findings in asymptomatic molecularly defined FH individuals, to identify those factors related to its presence and extension, and to assess the impact of these results in patients' care and estimated risk. METHODS: Four hundred and forty individuals with FH, without clinical cardiovascular disease, were consecutively enrolled and underwent a coronary CTA that was used to analyze coronary atherosclerosis based on coronary calcium score (CCS), sum of stenosis severity, and plaque composition sum (PCS). For FH patients, cardiovascular risk was estimated using the specific SAFEHEART risk equation. Follow-up was performed using a standardized protocol. RESULTS: Mean age was 46.4 years (231 women, 52%). Coronary calcium was present in 55%, mean CCS was 130.9, 46% had a plaque with lumen involvement, and mean PCS was 1.1. During follow-up, there were 17 (4%) nonfatal events and 2 (1%) fatal events. CCS was independently associated to the estimated risk and low-density lipoprotein-cholesterol life-years, sum of stenosis severity to the estimated risk, and PCS to the estimated risk and low-density lipoprotein-cholesterol life-years. CTA findings induced a positive change in patients' care and in their estimated risk. CONCLUSION: Coronary artery atherosclerosis is highly prevalent in asymptomatic patients with FH and it is independently associated to cardiovascular risk. More advanced disease on CTA was associated with subsequent intensification of therapy and reduction of estimated risk. Further longitudinal studies are required to know if these findings might improve the risk stratification in patients with FH.


Assuntos
Angiografia Coronária , Hiperlipoproteinemia Tipo II/diagnóstico , Adulto , Idoso , Cálcio/metabolismo , LDL-Colesterol/sangue , Constrição Patológica , Feminino , Seguimentos , Humanos , Hiperlipoproteinemia Tipo II/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico , Fatores de Risco , Tomografia Computadorizada por Raios X , Adulto Jovem
16.
Rev. esp. cardiol. (Ed. impr.) ; 71(2): 105-109, feb. 2018. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-170660

RESUMO

Introducción y objetivos: Está demostrado que la tomografía computarizada con multidetectores (TCMD) es una alternativa factible a la coronariografía invasiva (CI). Sin embargo, se han indicado resultados contradictorios sobre el efecto de la puntuación de calcio (PC) coronario en la precisión diagnóstica de la TCMD. El objetivo de este estudio es evaluar la concordancia entre la TCMD y la CI y evaluar la influencia de la PC en ella. Métodos: Se incluyó a 266 pacientes consecutivos sometidos a evaluación por TCMD de 64 cortes y por CI. Se utilizó el software habitual para la PC mediante el método Agatston. Un observador clasificó cualitativamente y de manera enmascarada las estenosis como leve, moderada o grave, y se compararon con los resultados obtenidos por la CI, utilizada como método de referencia. Resultados: La media de edad de los pacientes era 65,4 ± 11,2 años, y 188 (70,3%) eran varones. Se evaluó cualitativamente y se cuantificó por TCMD un total de 484 segmentos con estenosis coronaria al menos leve. Las mediciones no invasivas concordaban con la CI en 402 estenosis (el 83,05%; kappa = 0,684), sin diferencias significativas entre vasos y sin una influencia estadística significativa de la PC en la concordancia (OR = 0,93; IC95%, 0,76-1,09; p = 0,21). La TCMD tuvo sensibilidad, especificidad, valor predictivo positivo y valor predictivo negativo altos en los análisis por segmento, por vaso y por paciente. Conclusiones: La coronariografía no invasiva mediante TCMD mostró buena concordancia con la CI en la cuantificación cualitativa de las estenosis coronarias, y la PC no tuvo un impacto significativo en esa concordancia (AU)


Introduction and objectives: Multidetector computed tomography (MDCT) has been demonstrated as a feasible alternative to invasive coronary angiography (ICA). However, contradictory results have been reported regarding the effect of coronary artery calcium score (CS) on the diagnostic accuracy of MDCT. Our aim was to assess the agreement of MDCT and ICA and to evaluate the influence of CS on this agreement. Methods: We enrolled 266 consecutive patients who underwent evaluation with 64-slice MDCT and ICA. Standard CS software tools were used to calculate the Agatston score. Stenosis was qualitatively classified as mild, moderate, or severe by 1 blinded observer and the results were compared with those of ICA, which was used as the gold standard. Results: The mean age of the patients was 65.4 11.2 years, and 188 patients (70.3%) were men. A total of 484 segments with coronary stenosis mild were qualitatively evaluated and quantified with MDCT. Noninvasive measurements were concordant with ICA in 402 stenoses (83.05%; Kappa, 0.684), with no significant differences between vessels and with no statistically significant influence of CS on this agreement (OR, 0.93; 95%CI, 0.76-1.09; P = .21). Multidetector computed tomography had high sensitivity, specificity, positive predictive value, and negative predictive value on a per-segment, per-vessel, and per-patient basis. Conclusions: Non-ICA using MDCT showed good agreement with ICA in the qualitative quantification coronary stenosis and CS had no significant impact on this agreement (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Calcificação Vascular/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Angiografia Coronária/métodos , Cálcio/metabolismo , Estenose Coronária/diagnóstico por imagem , Valor Preditivo dos Testes , 24960/métodos , Sensibilidade e Especificidade , 28599
19.
Rev Esp Cardiol (Engl Ed) ; 71(9): 735-742, 2018 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29191782

RESUMO

INTRODUCTION AND OBJECTIVES: The SAPIEN 3 (S3) valve and the Medtronic Evolut R (EVR) are second-generation transcatheter valves, designed to further reduce the rate of paravalvular aortic regurgitation (AoR). The aim of this study was to compare the 2 devices in terms of valve performance in a case-matched study with independent echocardiographic analysis. METHODS: Of a population of 201 patients who underwent transcatheter aortic valve implantation, 144 patients (S3, n = 80; EVR, n = 64) were matched according to aortic annulus diameter and aortic valve calcium score, as assessed by computed tomography. All echocardiographic examinations collected at baseline and at 1- and 6-month follow-up were centrally analyzed. RESULTS: The 2 groups were well balanced in baseline clinical and echocardiographic characteristics. The EVR valve showed a better hemodynamic profile as assessed by peak aortic gradient (EVR 13 ± 7 vs S3 20 ± 10mmHg; P<.001), mean aortic gradient (EVR 7 ± 3 vs S3 11 ± 6mmHg; P<.001), and Doppler velocity index (EVR 0.65±0.15 vs S3 0.51±0.16; P<.001). The rate of moderate-severe or any paravalvular (≥ mild) AoR was higher in the EVR group (11% and 50%) than in the S3 group (2.5% and 21%; P <.05, respectively), with a larger number of paravalvular jets (P <.001). CONCLUSIONS: In a case-matched cohort of transcatheter aortic valve implantation patients, the S3 valve was associated with a lower rate of paravalvular AoR but also with a higher residual gradient than the EVR system.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Hemodinâmica/fisiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Desenho de Prótese , Tomografia Computadorizada por Raios X , Resultado do Tratamento
20.
Rev Esp Cardiol (Engl Ed) ; 71(2): 105-109, 2018 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28528881

RESUMO

INTRODUCTION AND OBJECTIVES: Multidetector computed tomography (MDCT) has been demonstrated as a feasible alternative to invasive coronary angiography (ICA). However, contradictory results have been reported regarding the effect of coronary artery calcium score (CS) on the diagnostic accuracy of MDCT. Our aim was to assess the agreement of MDCT and ICA and to evaluate the influence of CS on this agreement. METHODS: We enrolled 266 consecutive patients who underwent evaluation with 64-slice MDCT and ICA. Standard CS software tools were used to calculate the Agatston score. Stenosis was qualitatively classified as mild, moderate, or severe by 1 blinded observer and the results were compared with those of ICA, which was used as the gold standard. RESULTS: The mean age of the patients was 65.4 ± 11.2 years, and 188 patients (70.3%) were men. A total of 484 segments with coronary stenosis ≥ mild were qualitatively evaluated and quantified with MDCT. Noninvasive measurements were concordant with ICA in 402 stenoses (83.05%; Kappa, 0.684), with no significant differences between vessels and with no statistically significant influence of CS on this agreement (OR, 0.93; 95%CI, 0.76-1.09; P = .21). Multidetector computed tomography had high sensitivity, specificity, positive predictive value, and negative predictive value on a per-segment, per-vessel, and per-patient basis. CONCLUSIONS: Non-ICA using MDCT showed good agreement with ICA in the qualitative quantification coronary stenosis and CS had no significant impact on this agreement.


Assuntos
Calcinose/complicações , Cálcio/metabolismo , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada Multidetectores/métodos , Idoso , Calcinose/diagnóstico , Calcinose/metabolismo , Estenose Coronária/etiologia , Estenose Coronária/metabolismo , Vasos Coronários/metabolismo , Feminino , Humanos , Masculino , Curva ROC , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...