Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Genes Brain Behav ; 15(7): 637-46, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27283753

RESUMO

Neurofibromatosis type-1 (NF1) is a common neurogenetic disorder and an important cause of intellectual disability. Brain-behaviour associations can be examined in vivo using morphometric magnetic resonance imaging (MRI) and diffusion tensor imaging (DTI) to study brain structure. Here, we studied structural and behavioural phenotypes in heterozygous Nf1 mice (Nf1(+/-) ) using T2-weighted imaging MRI and DTI, with a focus on social recognition deficits. We found that Nf1(+/-) mice have larger volumes than wild-type (WT) mice in regions of interest involved in social cognition, the prefrontal cortex (PFC) and the caudate-putamen (CPu). Higher diffusivity was found across a distributed network of cortical and subcortical brain regions, within and beyond these regions. Significant differences were observed for the social recognition test. Most importantly, significant structure-function correlations were identified concerning social recognition performance and PFC volumes in Nf1(+/-) mice. Analyses of spatial learning corroborated the previously known deficits in the mutant mice, as corroborated by platform crossings, training quadrant time and average proximity measures. Moreover, linear discriminant analysis of spatial performance identified 2 separate sub-groups in Nf1(+/-) mice. A significant correlation between quadrant time and CPu volumes was found specifically for the sub-group of Nf1(+/-) mice with lower spatial learning performance, suggesting additional evidence for reorganization of this region. We found strong evidence that social and spatial cognition deficits can be associated with PFC/CPu structural changes and reorganization in NF1.


Assuntos
Encéfalo/fisiopatologia , Neurofibromatose 1/fisiopatologia , Animais , Comportamento Animal/fisiologia , Encéfalo/diagnóstico por imagem , Cognição/fisiologia , Transtornos Cognitivos/diagnóstico por imagem , Transtornos Cognitivos/fisiopatologia , Imagem de Tensor de Difusão , Modelos Animais de Doenças , Feminino , Imageamento por Ressonância Magnética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Neurofibromatose 1/diagnóstico por imagem , Fenótipo , Córtex Pré-Frontal/diagnóstico por imagem , Córtex Pré-Frontal/fisiopatologia , Comportamento Social , Transtornos do Comportamento Social/fisiopatologia , Relação Estrutura-Atividade
2.
Magn Reson Med ; 67(3): 595-600, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22189839

RESUMO

Magnetic resonance imaging is widely used in the work-up and monitoring of patients with Crohn's disease. Balanced steady-state free precession sequences are an important part of the imaging protocol and until now primarily 1.5T scanners have been used in daily clinical practice. This is largely because running balanced steady-state free precession sequences in 3T magnets has technical problems related to increased B(0) inhomogeneity and specific absorption rate (SAR) deposition. A modified form of alternating repetition time steady-state free precession sequence is presented to acquire 3D-isotropic abdominal images with fat-suppression at 3T within a breath-hold. The modifications include an adjusted radiofrequency pulse shape, suitable phase-cycling scheme and TR(1)/TR(2) ratio. Results show that the proposed sequence is successful in obtaining high contrast 3D-isotropic abdominal images within a breath-hold. Furthermore, the proposed methodology is easy to implement in a clinical setting and does not require any postprocessing steps.


Assuntos
Doença de Crohn/diagnóstico , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Gordura Abdominal/anatomia & histologia , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
3.
Neuroimage ; 47(1): 69-76, 2009 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-19376236

RESUMO

In EEG/fMRI correlation studies it is common to consider the fMRI BOLD as filtered version of the EEG alpha power. Here the question is addressed whether other EEG frequency components may affect the correlation between alpha and BOLD. This was done comparing the statistical parametric maps (SPMs) of three different filter models wherein either the free or the standard hemodynamic response functions (HRF) were used in combination with the full spectral bandwidth of the EEG. EEG and fMRI were co-registered in a 30 min resting state condition in 15 healthy young subjects. Power variations in the delta, theta, alpha, beta and gamma bands were extracted from the EEG and used as regressors in a general linear model. Statistical parametric maps (SPMs) were computed using three different filter models, wherein either the free or the standard hemodynamic response functions (HRF) were used in combination with the full spectral bandwidth of the EEG. Results show that the SPMs of different EEG frequency bands, when significant, are very similar to that of the alpha rhythm. This is true in particular for the beta band, despite the fact that the alpha harmonics were discarded. It is shown that inclusion of EEG frequency bands as confounder in the fMRI-alpha correlation model has a large effect on the resulting SPM, in particular when for each frequency band the HRF is extracted from the data. We conclude that power fluctuations of different EEG frequency bands are mutually highly correlated, and that a multi frequency model is required to extract the SPM of the frequency of interest from EEG/fMRI data. When no constraints are put on the shapes of the HRFs of the nuisance frequencies, the correlation model looses so much statistical power that no correlations can be detected.


Assuntos
Encéfalo/fisiologia , Eletroencefalografia , Imageamento por Ressonância Magnética , Adulto , Ritmo alfa , Feminino , Humanos , Modelos Lineares , Masculino
4.
Neuroimage ; 42(1): 112-21, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18539049

RESUMO

Considering that there are several theoretical reasons why fMRI data is correlated to variations in heart rate, these correlations are explored using experimental resting state data. In particular, the possibility is discussed that the "default network", being a brain area that deactivates during non-specific general tasks, is a hemodynamic effect caused by heart rate variations. Of fifteen healthy controls ECG, EEG and fMRI were co-registered. Slice time dependent heart rate regressors were derived from the ECG data and correlated to fMRI using a linear correlation analysis where the impulse response is estimated from the data. It was found that in most subjects substantial correlations between heart rate variations and fMRI exist, both within the brain and at the ventricles. The brain areas with high correlation to heart rate are different from the "default network" and the response functions deviate from the canonical hemodynamic response function. Furthermore, a general negative correlation was found between heart beat intervals (reverse of heart rate) and alpha power. We interpret this finding by assuming that subject's state varies between drowsiness and wakefulness. Finally, given this large correlation, we re-examined the contribution of heart rate variations to earlier reported fMRI/alpha band correlations, by adding heart rate regressors as confounders. It was found that inclusion of these confounders most often had a negligible effect. From its strong correlation to alpha power, we conclude that the heart rate variations contain important physiological information about subject's resting state. However, it does not provide a full explanation of the behaviour of the "default network". Its application as confounder in fMRI experiments is a relatively small computational effort, but may have a substantial impact in paradigms where heart rate is controlled by the stimulus.


Assuntos
Ritmo alfa/métodos , Encéfalo/fisiologia , Frequência Cardíaca/fisiologia , Imageamento por Ressonância Magnética/métodos , Modelos Cardiovasculares , Modelos Neurológicos , Descanso/fisiologia , Adulto , Simulação por Computador , Feminino , Humanos , Masculino
5.
Eur J Pharm Biopharm ; 68(3): 760-70, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17964129

RESUMO

Manufacturing of 'ready-to-compress' powder mixtures for direct compression was performed by spray drying, without granulation, milling and/or blending steps in between spray drying and compaction. Powder mixtures containing acetaminophen, mannitol, erythritol, maltodextrin, crospovidone, colloidal silicon dioxide and polyoxyethylene 20 sorbitan monooleate were prepared via co-spray drying. A feed suspension having a solid content of 27.2% w/w was selected for further process optimisation because of its high process yield, excellent flowability and short tablet disintegration time. Experimental design was applied to evaluate processibility, physico-chemical properties and compactability of the spray dried powder mixtures. Significant and adequate regression models were developed for powder flowability, median particle size, bulk density, residual moisture content and process yield. An increasing inlet and outlet drying air temperature improved process yield. However, a higher inlet drying air temperature had a negative influence on density and moisture content, while the latter decreased at higher outlet drying air temperatures. Median particle size increased with a higher inlet temperature, while the outlet temperature had the opposite affect. Numerical optimisation determined the optimal spray drying process (inlet temperature: 221 degrees C, outlet temperature: 81 degrees C and atomisation pressure: 6 bar) in order to produce 'ready-to-compress' powder mixtures.


Assuntos
Comprimidos , Tecnologia Farmacêutica , Acetaminofen/administração & dosagem , Tamanho da Partícula , Pós , Resistência à Tração , Água
6.
Clin Neurophysiol ; 118(11): 2437-50, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17889599

RESUMO

OBJECTIVE: Co-registration of EEG (electroencephalogram) and fMRI (functional magnetic resonance imaging) remains a challenge due to the large artifacts induced on the EEG by the MR (magnetic resonance) sequence magnetic fields. Thus, we present an algorithm, based on the average-subtraction method, which is able to correct EEG data for gradient and pulse artifacts. METHODS: MR sequence timing parameters are estimated from the EEG data and both slice and volume artifact templates are subtracted from the data. A clustering algorithm is proposed to account for the variability of the pulse artifact. RESULTS: The algorithm is able to keep the spontaneous EEG as well as visual evoked potentials (VEPs), while removing gradient and pulse artifacts with only a subtraction of selectively averaged data. In the frequency domain, the artifact frequencies are strongly attenuated. Estimated MR sequence time parameters showed that the correction is extremely sensitive to the slice time value. Pulse artifact clustering showed that most of the variability is due to the time jitter of the pulse artifact markers. CONCLUSIONS: Selective subtraction of averages in combination with proper time alignment is enough to remove most of the MR-induced artifacts. SIGNIFICANCE: Clean EEG can be obtained from raw signals that are corrupted by MR-induced artifacts during simultaneous EEG-fMRI scanning without using dedicated hardware to synchronize EEG and fMRI clocks.


Assuntos
Artefatos , Eletroencefalografia , Imageamento por Ressonância Magnética , Técnica de Subtração , Adolescente , Adulto , Encéfalo/irrigação sanguínea , Encéfalo/fisiologia , Peróxido de Carbamida , Combinação de Medicamentos , Potenciais Evocados Visuais/fisiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Peróxidos/sangue , Imagens de Fantasmas , Estimulação Luminosa/métodos , Análise de Componente Principal , Análise Espectral , Ureia/análogos & derivados , Ureia/sangue
7.
Neuroimage ; 35(3): 1142-51, 2007 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-17336548

RESUMO

EEG was recorded during fMRI scanning of 16 normal controls in resting condition with eyes closed. Time variations of the occipital alpha band amplitudes were correlated to the fMRI signal variations to obtain insight into the hemodynamic correlates of the EEG alpha activity. Contrary to earlier studies, no a priori assumptions were made on the expected shape of the alpha band response function (ARF). The ARF of different brain regions and subjects were explored and compared. It was found that: (1) the ARF of the thalamus is mainly positive. (2) The ARFs at the occipital and left and right parietal points are similar in amplitude and timing. (3) The peak time of the thalamus is a few seconds earlier than that of occipital and parietal cortex. (4) No systematic BOLD activity was found preceding the alpha band activity, although in the two subjects with the strongest alpha band power such correlation was present. (5) There is a strong and immediate positive correlation at the eyeball, and a strong negative correlation at the back of the eye. Furthermore, it was found that in one subject the cortical ARF was positive, contrary to the other subjects. Finally, a cluster analysis of the observed ARF, in combination with a Modulated Sine Model (MSM) fit to the estimated ARF, revealed that within the cortex the ARF peak time shows a spatial pattern that may be interpreted as a traveling wave. The spatial pattern of alpha band response function represents the combined effect of local differences in electrical alpha band activity and local differences in the hemodynamic response function (HRF) onto these electrical activities. To disentangle the contributions of both factors, more advanced integration of EEG inverse modeling and hemodynamic response modeling is required in future studies.


Assuntos
Ritmo alfa/métodos , Mapeamento Encefálico/métodos , Encéfalo/irrigação sanguínea , Encéfalo/fisiologia , Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética/métodos , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Neuroimage ; 30(1): 203-13, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16290018

RESUMO

Simultaneous recording of electroencephalogram/functional magnetic resonance images (EEG/fMRI) was applied to identify blood oxygenation level-dependent (BOLD) changes associated with spontaneous variations of the alpha rhythm, which is considered the hallmark of the brain resting state. The analysis was focused on inter-subject variability associated with the resting state. Data from 7 normal subjects are presented. Confirming earlier findings, three subjects showed a negative correlation between the BOLD signal and the average power time series within the alpha band (8--12 Hz) in extensive areas of the occipital, parietal and frontal lobes. In small thalamic areas, the BOLD signal was positively correlated with the alpha power. For subjects 3 and 4, who displayed two different states during the data acquisition time, it was shown that the corresponding correlation patterns were different, thus demonstrating the state dependency of the results. In subject 5, the changes in BOLD were observed mainly in the frontal and temporal lobes. Subject 6 only showed positive correlations, thus contradicting the negative BOLD alpha power cortical correlations that were found in most subjects. Results suggest that the resting state varies over subjects and, sometimes, even within one subject. As the resting state plays an important role in many fMRI experiments, the inter-subject variability of this state should be addressed when comparing fMRI results from different subjects.


Assuntos
Ritmo alfa , Córtex Cerebral/fisiologia , Eletroencefalografia , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Oxigênio/sangue , Processamento de Sinais Assistido por Computador , Adulto , Mapeamento Encefálico , Córtex Cerebral/irrigação sanguínea , Feminino , Humanos , Masculino , Padrões de Referência , Sensibilidade e Especificidade , Estatística como Assunto , Tálamo/irrigação sanguínea , Tálamo/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...