Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 41(10): 617-620, Dic. 2023. tab
Artigo em Inglês | IBECS | ID: ibc-228362

RESUMO

Introduction: Respiratory infection is the most common human adenovirus (HAdV) disease accounting for 7–8% of viral respiratory diseases in children less than 5 years. Differentiation of bacterial infections and viral infections is a common clinical problem. Material and methods: One hundred oropharyngeal swabs obtained from October 2019 to November 2020 from patients attending the paediatric emergency room with suspicion of upper respiratory tract infection and negative results in influenza and RSV tests were included. Oropharyngeal swabs specimens were rapidly processed with STANDARD™ F Adeno Respi Ag FIA and the results were confirmed by RealStar® Adenovirus PCR Kit 1.0 (Altona diagnostics). Results: STANDARD™ F Adeno Respi Ag FIA had sensitivity and specificity values of 71.93% and 100% respectively. The performance of the test was higher in samples from children younger than 24 months and taken less than 72h since the beginning of symptoms. In this subgroup the test had 88.8% sensitivity and 100% specificity. Conclusion: STANDARD™ F Adeno Respi Ag FIA may improve the management of respiratory diseases in children younger than 24 months and less than 72h since the beginning of symptoms in paediatric emergency rooms.(AU)


Introducción: Las infecciones respiratorias son la enfermedad más común asociada a los adenovirus humanos (AdvH)y causan del 7 al 8% de las enfermedades respiratorias víricas en niños menores de 5 años. La distinción entre las infecciones bacterianas y las víricas constituye un problema clínico frecuente. Materiales y métodos: El estudio incluyó 100 hisopos orofaríngeos obtenidos entre octubre de 2019 y noviembre de 2020 de pacientes que habían acudido a los servicios de urgencias pediátricas con sospecha de infección de las vías respiratorias superiores y resultados negativos en las pruebas de gripe y VRS. Las muestras de los hisopos orofaríngeos se procesaron rápidamente con Standard™ F Adeno Respi Ag FIA y los resultados se confirmaron mediante RealStar® Adenovirus PCR Kit 1.0 (altona Diagnostics). Resultados: Standard™ F Adeno Respi Ag FIA tenía unos valores de sensibilidad y especificidad del 71,93% y el 100%, respectivamente. El rendimiento de la prueba fue superior en muestras de niños menores de 24 meses y tomadas menos de 72 horas después del inicio de los síntomas. En este subgrupo, la prueba tuvo una sensibilidad del 88,8% y una especificidad del 100%. Conclusión: Standard™ F Adeno Respi Ag FIA puede mejorar la gestión de las enfermedades respiratorias en niños menores de 24 meses con menos de 72 desde el inicio de los síntomas en servicios de urgencias pediátricas.(AU)


Assuntos
Humanos , Masculino , Feminino , Criança , Doenças Respiratórias/diagnóstico , Adenovírus Humanos , Infecções Bacterianas/microbiologia , Viroses/microbiologia , Serviços Médicos de Emergência , Reação em Cadeia da Polimerase , Doenças Transmissíveis , Microbiologia , Infecções Bacterianas/diagnóstico , Infecções Bacterianas/tratamento farmacológico , Viroses/diagnóstico , Técnicas Microbiológicas
2.
Enferm Infecc Microbiol Clin (Engl Ed) ; 41(10): 617-620, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37076330

RESUMO

INTRODUCTION: Respiratory infection is the most common human adenovirus (HAdV) disease accounting for 7-8% of viral respiratory diseases in children less than 5 years. Differentiation of bacterial infections and viral infections is a common clinical problem. MATERIAL AND METHODS: One hundred oropharyngeal swabs obtained from October 2019 to November 2020 from patients attending the paediatric emergency room with suspicion of upper respiratory tract infection and negative results in influenza and RSV tests were included. Oropharyngeal swabs specimens were rapidly processed with STANDARD™ F Adeno Respi Ag FIA and the results were confirmed by RealStar® Adenovirus PCR Kit 1.0 (Altona diagnostics). RESULTS: STANDARD™ F Adeno Respi Ag FIA had sensitivity and specificity values of 71.93% and 100% respectively. The performance of the test was higher in samples from children younger than 24 months and taken less than 72h since the beginning of symptoms. In this subgroup the test had 88.8% sensitivity and 100% specificity. CONCLUSION: STANDARD™ F Adeno Respi Ag FIA may improve the management of respiratory diseases in children younger than 24 months and less than 72h since the beginning of symptoms in paediatric emergency rooms.


Assuntos
Infecções por Adenoviridae , Adenovírus Humanos , Infecções Respiratórias , Humanos , Criança , Adenoviridae , Infecções por Adenoviridae/diagnóstico , Infecções Respiratórias/diagnóstico , Reação em Cadeia da Polimerase , Adenovírus Humanos/genética
3.
Arch Dis Child ; 107(11): 1051-1058, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35688603

RESUMO

OBJECTIVES: To evaluate the performance of oral saliva swab (OSS) reverse transcription PCR (RT-PCR) compared with RT-PCR and antigen rapid diagnostic test (Ag-RDT) on nasopharyngeal swabs (NPS) for SARS-CoV-2 in children. DESIGN: Cross-sectional multicentre diagnostic study. SETTING: Study nested in a prospective, observational cohort (EPICO-AEP) performed between February and March 2021 including 10 hospitals in Spain. PATIENTS: Children from 0 to 18 years with symptoms compatible with Covid-19 of ≤5 days of duration were included. Two NPS samples (Ag-RDT and RT-PCR) and one OSS sample for RT-PCR were collected. MAIN OUTCOME: Performance of Ag-RDT and RT-PCR on NPS and RT-PCR on OSS sample for SARS-CoV-2. RESULTS: 1174 children were included, aged 3.8 years (IQR 1.7-9.0); 73/1174 (6.2%) patients tested positive by at least one of the techniques. Sensitivity and specificity of OSS RT-PCR were 72.1% (95% CI 59.7 to 81.9) and 99.6% (95% CI 99 to 99.9), respectively, versus 61.8% (95% CI 49.1 to 73) and 99.9% (95% CI 99.4 to 100) for the Ag-RDT. Kappa index was 0.79 (95% CI 0.72 to 0.88) for OSS RT-PCR and 0.74 (95% CI 0.65 to 0.84) for Ag-RDT versus NPS RT-PCR. CONCLUSIONS: RT-PCR on the OSS sample is an accurate option for SARS-CoV-2 testing in children. A less intrusive technique for younger patients, who usually are tested frequently, might increase the number of patients tested.


Assuntos
COVID-19 , Criança , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , Teste para COVID-19 , Saliva , Transcrição Reversa , Estudos Prospectivos , Estudos Transversais , Sensibilidade e Especificidade , Reação em Cadeia da Polimerase
4.
J Clin Virol ; 143: 104961, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34461560

RESUMO

OBJECTIVES: RT-PCR assay is the reference method for diagnosis of COVID-19, but it is also a laborious and time-consuming technic, limiting the availability of testing. Rapid antigen-detection tests are faster and less expensive; however, the reliability of these tests must be validated before they can be used widely. The objective of this study was to determine the performance of the Clinitest Rapid COVID-19 Antigen Test (ClinitestRT) (SIEMENS) for SARS-CoV-2 in nasopharyngeal swab specimens. METHODS: This prospective multicenter study was carried out in three Spanish university hospitals including individuals with clinical symptoms or epidemiological criteria for COVID-19. Only individuals with ≤7 days from the onset of symptoms or from exposure to a confirmed case of COVID-19 were included. Two nasopharyngeal samples were taken to perform the ClinitestRT, as a point-of-care test, and a diagnostic RT-PCR test. RESULTS: Overall sensitivity and specificity for the ClinitestRT among the 450 patients studied were 93.3% (CI 95%: 89.7-96.8) and 99.2% (CI 95%: 97.2-99.8), respectively. Sensitivity in participants with ≤5 days of the clinical course was 93.6% (CI 95%: 89.2-96.3), and in participants who had a CT < 25 for the RT-PCR test was 98.4% (CI 95%: 94.5-99.6). Agreement between techniques was 96.7% (kappa score: 0.93; CI 95%: 0.90-0.97). CONCLUSIONS: The ClinitestRT provides good clinical performance, with more reliable results for patients with a higher viral load. The results must be interpreted based on the local epidemiological context.


Assuntos
COVID-19 , SARS-CoV-2 , Antígenos Virais , Ácido Cítrico , Sulfato de Cobre , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Bicarbonato de Sódio
5.
Pediatr Infect Dis J ; 40(11): 1034-1036, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34321448

RESUMO

A screening of Chlamydia trachomatis infection in young pregnant women (≤25 years old) and their newborns was conducted. A total of 136 women were tested with urine samples in the immediate postpartum period. The prevalence was 18.4% (95% confidence interval [CI]: 11.9-24.9%) (25/136) and the rate of perinatal transmission was 35% (7/20). These results support the need for antenatal screening programs in high-risk women in Madrid (Spain).


Assuntos
Infecções por Chlamydia/diagnóstico , Chlamydia trachomatis/isolamento & purificação , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Complicações Infecciosas na Gravidez/prevenção & controle , Diagnóstico Pré-Natal/normas , Adolescente , Adulto , Infecções por Chlamydia/epidemiologia , Infecções por Chlamydia/transmissão , Infecções por Chlamydia/urina , Chlamydia trachomatis/genética , Feminino , Humanos , Gravidez , Complicações Infecciosas na Gravidez/epidemiologia , Gestantes , Diagnóstico Pré-Natal/estatística & dados numéricos , Prevalência , Estudos Prospectivos , Fatores de Risco , Espanha/epidemiologia , Adulto Jovem
6.
Pediatr Infect Dis J ; 40(5): 385-388, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33605674

RESUMO

BACKGROUND: Real-time reverse transcription-quantitative polymerase chain reaction (RT-qPCR) is the reference laboratory method to diagnose SARS-CoV-2 infection then requires equipment and is time-consuming. There is a crucial demand for rapid techniques such as antigen detection test. Considering the different diagnostic accuracy of tests with other respiratory viruses in adults and children, SARS-CoV-2 antigen test must be evaluated specifically in children. METHODS: The purpose of this study was to evaluate the performance of Panbio COVID-19 Ag Rapid Test Device (Abbott) as a point-of-care test for diagnosis of SARS-CoV-2 in comparison to RT-qPCR in a pediatric population. RESULTS: Four hundred forty nasopharyngeal swabs were tested. Amongst the 18 positive RT-qPCR samples, 14 were detected by the rapid antigen test, given an overall sensitivity of 77.7%. All the samples detected positive with the antigen rapid test were also positive with RT-qPCR. CONCLUSION: The sensitivity of Panbio COVID-19 Ag Rapid Test Device is lower in children than in adults. Nevertheless, considering the good values of specificity, negative and positive predictive values this test could be used as a frontline test to obtain quick results, although the negative values with COVID-19 high clinical suspicion should be confirmed using RT-qPCR.


Assuntos
Antígenos Virais/isolamento & purificação , Teste de Ácido Nucleico para COVID-19 , Teste Sorológico para COVID-19 , COVID-19/diagnóstico , SARS-CoV-2/isolamento & purificação , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Testes Imediatos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade
7.
Artigo em Inglês | MEDLINE | ID: mdl-33601009

RESUMO

OBJECTIVES: The standard RT-PCR assay for coronavirus disease 2019 (COVID-19) is laborious and time-consuming, limiting testing availability. Rapid antigen-detection tests are faster and less expensive; however, the reliability of these tests must be validated before they can be used widely. The objective of this study was to determine the performance of the Panbio™ COVID-19 Ag Rapid Test Device (PanbioRT) (Abbott) in detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in nasopharyngeal swab specimens. METHODS: This prospective multicentre study was carried out in ten Spanish university hospitals and included individuals with clinical symptoms or epidemiological criteria of COVID-19. Only individuals with ≤7 days from the onset of symptoms or from exposure to a confirmed case of COVID-19 were included. Two nasopharyngeal samples were taken to perform the PanbioRT as a point-of-care test and a diagnostic RT-PCR test. RESULTS: Among the 958 patients studied, 325 (90.5%) had true-positive results. The overall sensitivity and specificity for the PanbioRT were 90.5% (95%CI 87.5-93.6) and 98.8% (95%CI 98-99.7), respectively. Sensitivity in participants who had a threshold cycle (CT) < 25 for the RT-PCR test was 99.5% (95%CI 98.4-100), and in participants with ≤5 days of the clinical course it was 91.8% (95%CI 88.8-94.8). Agreement between techniques was 95.7% (κ score 0.90; 95%CI 0.88-0.93). CONCLUSIONS: The PanbioRT performs well clinically, with even more reliable results for patients with a shorter clinical course of the disease or a higher viral load. The results must be interpreted based on the local epidemiological context.

9.
Eur J Clin Microbiol Infect Dis ; 39(12): 2289-2297, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32808111

RESUMO

Lateral flow immunoassays (LFIA) for rapid detection of specific antibodies (IgM and IgG) against SARS-CoV-2 in different human specimens have been developed in response to the pandemic. The aim of this study is to evaluate three immunocromathographic assays (Sienna®, Wondfo® and Prometheus®) for detection of antibodies against SARS-CoV-2 in serum samples, considering RT-qPCR as a reference. A total of 145 serum samples from 145 patients with clinical suspicion of COVID-19 were collected: all of the samples were tested with Sienna®, 117 with Wondfo® and 89 with Prometheus®. The overall results of sensitivity, specificity, positive predictive value and negative predictive value obtained were as follows: 64.4%, 75%, 85.5% and 47.8% with Sienna®; 45.2%, 81.8%, 80.5% and 47.4% with Wondfo® and 75.5%, 12.5%, 51.4% and 29.4% with Prometheus®. The accuracy of the test for Sienna®, Wondfo® and Prometheus® was 67.6%, 59% and 47.2%, with a prevalence of COVID-19 of 69.7%, 62.4% and 55.1% respectively. Sensitivity of the three tests (Sienna®, Wondfo® and Prometheus® respectively) along the three different stages was 36.6%, 18.8% and 68.6% in the early stage (first week); 81.3%, 74.1% and 90.9% in the intermediate stage (second week) and 100%, 83.3% and 100% in the late stage (third week). The results demonstrate that even though Prometheus® presented a high sensitivity, the specificity was notably lower than the other two tests. Sienna® showed the greatest contrast between sensitivity and specificity, achieving the best accuracy, followed by Wondfo®. The sensitivity of the three ICT assays was higher in late stages of the disease.


Assuntos
Anticorpos Antivirais/sangue , Betacoronavirus/imunologia , Cromatografia de Afinidade/métodos , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Pandemias , Pneumonia Viral/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Betacoronavirus/patogenicidade , COVID-19 , Teste para COVID-19 , Estudos de Casos e Controles , Infecções por Coronavirus/sangue , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/imunologia , Reações Falso-Positivas , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Masculino , Pessoa de Meia-Idade , Pneumonia Viral/sangue , Pneumonia Viral/epidemiologia , Pneumonia Viral/imunologia , Kit de Reagentes para Diagnóstico/normas , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , SARS-CoV-2 , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Espanha/epidemiologia
11.
J Infect ; 79(3): 277-287, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31102602

RESUMO

The FilmArray® meningitis/encephalitis panel detects the 14 most frequent pathogens causing meningitis and/or encephalitis. The cases of FilmArray´s false negative in bacterial meningitis are rarely described in the literature. We are reporting a case of a false negative FilmArray® result for N. meningitidis and how we managed to overcome this situation.


Assuntos
Encefalite , Meningites Bacterianas , Meningite Meningocócica , Tuberculose Meníngea , Humanos , Reação em Cadeia da Polimerase Multiplex
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...