Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
6.
Sensors (Basel) ; 23(6)2023 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-36992002

RESUMO

Sensor-based devices can record pressure or force over time during grasping and therefore offer a more comprehensive approach to quantifying grip strength during sustained contractions. The objectives of this study were to investigate the reliability and concurrent validity of measures of maximal tactile pressures and forces during a sustained grasp task using a TactArray device in people with stroke. Participants with stroke (n = 11) performed three trials of sustained maximal grasp over 8 s. Both hands were tested in within- and between-day sessions, with and without vision. Measures of maximal tactile pressures and forces were measured for the complete (8 s) grasp duration and plateau phase (5 s). Tactile measures are reported using the highest value among three trials, the mean of two trials, and the mean of three trials. Reliability was determined using changes in mean, coefficients of variation, and intraclass correlation coefficients (ICCs). Pearson correlation coefficients were used to evaluate concurrent validity. This study found that measures of reliability assessed by changes in means were good, coefficients of variation were good to acceptable, and ICCs were very good for maximal tactile pressures using the average pressure of the mean of three trials over 8 s in the affected hand with and without vision for within-day sessions and without vision for between-day sessions. In the less affected hand, changes in mean were very good, coefficients of variations were acceptable, and ICCs were good to very good for maximal tactile pressures using the average pressure of the mean of three trials over 8 s and 5 s, respectively, in between-day sessions with and without vision. Maximal tactile pressures had moderate correlations with grip strength. The TactArray device demonstrates satisfactory reliability and concurrent validity for measures of maximal tactile pressures in people with stroke.


Assuntos
Acidente Vascular Cerebral , Tato , Humanos , Reprodutibilidade dos Testes , Mãos , Força da Mão
7.
Int J Stroke ; 17(9): 972-982, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35034522

RESUMO

BACKGROUND: Over the past few years, the incidence and prevalence of stroke has been rising in most African countries and has been reported as one of the leading causes of morbidity and mortality. To study this problem, we need to realize the quality and availability of stroke care services as a priori to improve them. METHODS AND RESULTS: In this study, we investigated the availability of different stroke-related services in 17 countries from different African regions. An online survey was conducted and fulfilled by stroke specialists and included primary prevention, acute management, diagnostic tools, medications, postdischarge services, and stroke registries. The results showed that although medications for secondary prevention are available, yet many other services are lacking in various countries. CONCLUSION: This study displays the deficient aspects of stroke services in African countries as a preliminary step toward active corrective procedures for the improvement of stroke-related health services.


Assuntos
Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/terapia , Assistência ao Convalescente , Alta do Paciente , Prevenção Secundária , África/epidemiologia
9.
Somatosens Mot Res ; 36(4): 249-261, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31607190

RESUMO

Objective: To investigate the reliability and the concurrent validity of maximal tactile pressures and forces of a sustained grasp task using a TactArray device in healthy adults.Methods: Healthy participants (n = 18, mean age: 62.2 ± 9.9 years) performed three repeat trials of sustained maximal grasp over 8 seconds. Both hands were tested in within-day and between-day sessions, with vision and without vision. Measures of maximal tactile pressures and forces were measured for the complete grasp duration (8s) and for the plateau phase (5s). Measures of maximal tactile pressures and forces were reported using the highest value among three repeat trials, the mean of two repeat trials, and the mean of three repeat trials. Reliability was determined using changes in mean, coefficients of variation and intraclass correlation coefficients (ICCs). Pearson correlation coefficients were used to evaluate concurrent validity.Results: Changes in mean were very good, coefficients of variation were good to acceptable and ICCs were very good to good for maximal tactile pressures using the highest value among three repeat trials and the mean of three repeat trials for the complete grasp duration (8s) and for the plateau phase (5s) in the dominant hand with and without vision and in the non-dominant hand without vision for within-day and between-day sessions. Maximal tactile pressures had moderate to large correlations with grip strength.Conclusion: The TactArray device demonstrates satisfactory reliability for maximal tactile pressures during a sustained grasp for within-day and between-day testing sessions in both hands. Validity was satisfactory with grip strength in both hands.


Assuntos
Fenômenos Biomecânicos/fisiologia , Retroalimentação Sensorial/fisiologia , Mãos/fisiologia , Atividade Motora/fisiologia , Desempenho Psicomotor/fisiologia , Idoso , Feminino , Lateralidade Funcional/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
10.
Physiother Res Int ; 24(1): e1748, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30230136

RESUMO

BACKGROUND AND PURPOSE: After stroke, reach-to-grasp goal-directed movements are disrupted as a result of both residual motor and somatosensory impairments. This report describes the rationale and development of a new upper limb stroke rehabilitation intervention known as COMPoSE: "COMbined Physical and somatoSEnsory training," designed to improve somatosensory and motor deficits in the upper limb after stroke. A standardized training matrix has been developed to facilitate intervention delivery. METHODS: The COMPoSE intervention was developed through the following stages: (a) Definition and operationalization of somatosensory and motor variables used in training sensation and movement after stroke; (b) development of methods to give feedback to enhance skill acquisition; and (c) Combination of somatosensory and motor variables, and feedback, into a standardized training matrix. The reporting of the COMPoSE intervention adheres to the recommendations of the Template for Intervention Description and Replication checklist to facilitate replication of the intervention in the future. RESULTS: The essential features of COMPoSE include combined somatosensory-motor training variables (grasp pressure, distance, object size, crushability, surface texture, and friction), feedback, and calibration using a haptic device providing measures of grasp pressure, use of anticipation trials, and high-dose repetitive task practice. Ten treatment sessions are delivered over 3 weeks, using a standardized matrix for treatment delivery. CONCLUSION: COMPoSE is a new intervention that combines somatosensory and movement training, delivered synchronously, within the same intervention, and within the same task.


Assuntos
Estimulação Física/métodos , Distúrbios Somatossensoriais/etiologia , Distúrbios Somatossensoriais/terapia , Reabilitação do Acidente Vascular Cerebral/métodos , Extremidade Superior/fisiopatologia , Força da Mão , Humanos , Masculino , Movimento , Recuperação de Função Fisiológica , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/fisiopatologia , Extremidade Superior/inervação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...