Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Eur J Radiol Open ; 7: 100217, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33102636

RESUMO

PURPOSE: To assess the value of MRI obtained before and after treatment in detecting mucosal healing in patients with ileal Crohn's disease (CD) treated with anti-TNF drugs. METHODS: In this IRB approved retrospective study, 24 patients (M/F 11/13, age 34.0 ± 12.5 years, age range 19-55 years) with ileal CD who underwent anti-TNF treatment, with pre- and post-treatment MRI (mean delay between MRIs 92 ± 57 weeks) were included. All patients underwent routine MR enterography (MRE), which included diffusion-weighted imaging (DWI). Two readers evaluated qualitative features (wall thickness, presence of edema and length of involvement) in consensus and one reader measured the following quantitative variables: relative contrast enhancement (RCE) and apparent diffusion coefficient (ADC) to derive the MaRIA and Clermont scores at baseline, post-treatment and their changes (ΔMaRIA, ΔClermont). Ileocolonoscopy results were used as the reference standard. Data was evaluated using Mann-Whitney U test and receiver operating characteristics analysis to assess the utility of the measures for the detection of mucosal healing. RESULTS: Twenty-four ileal segments were assessed in 24 patients. Nine patients showed mucosal healing while 15 had no mucosal healing on post-treatment endoscopy. Pre-treatment Clermont score and wall thickness and post-treatment MaRIA and Clermont scores, wall thickness, edema, length of involvement as well as ΔMaRIA and ΔClermont were all significantly different in patients with and without mucosal healing (p-range: 0.001-0.041) while MaRIA pre-treatment and ADC pre- and post-treatment were not. Pre-treatment Clermont score as well as post-treatment MaRIA and Clermont scores, wall thickness and ΔMaRIA were all significantly predictive of detection of mucosal healing (AUC 0.813-0.912; p = 0.003-0.024) after anti-TNF treatment. CONCLUSION: Pre-treatment Clermont score as well as post-treatment MaRIA and Clermont scores, wall thickness and ΔMaRIA are significantly predictive of response to anti-TNF drugs in ileal Crohn's disease. These results need to be verified in a larger study.

3.
Eur J Radiol ; 126: 108949, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32179424

RESUMO

PURPOSE: To investigate the utility of magnetic resonance elastography (MRE) vs. ultrasound (US) point shear wave elastography (pSWE) for the assessment of chronic renal allograft dysfunction, prediction of outcome and determine the correlation with Banff pathology scores. METHODS: In this IRB approved prospective study, 27 enrolled patients with functional (n = 15) and chronic dysfunctional (n = 12) renal allografts underwent same day 2D MRE and pSWE. Histogram parameters [including mean, median, standard deviation, kurtosis and skewness] of the magnitude of the complex shear modulus (MRE) and median Young's modulus (pSWE) were measured in the cortex (MRE and pSWE) and combined corticomedullary regions (MRE). Histopathology was available for 16 patients (4 functional, 12 dysfunctional). RESULTS: MRE and pSWE stiffness were not significantly different between functional and dysfunctional groups (p range 0.139-0.347). The skewness of MRE corticomedullary stiffness was significantly lower (p = 0.04) in patients with chronic dysfunction and correlated significantly with Banff histopathologic scores (range r=-0.518-0.567, p = 0.035-0.040). MRE cortical and corticomedullary mean stiffness showed strong performance in predicting graft loss/relist (AUC 0.958, p = 0.011 for both). Reliable pSWE measurements were obtained in 13 patients (48 %). pSWE stiffness did not correlate with Banff scores and did not predict outcome. CONCLUSIONS: The skewness of MRE corticomedullary stiffness is sensitive to changes in chronic allograft dysfunction, while mean/median MRE renal stiffness and median US stiffness did not differentiate patients with stable function vs those with chronic renal allograft dysfunction. MRE corticomedullary mean stiffness appears to be a predictor of graft loss/relist. pSWE was not found to be a useful method for assessing renal allografts.


Assuntos
Aloenxertos/diagnóstico por imagem , Aloenxertos/fisiopatologia , Técnicas de Imagem por Elasticidade/métodos , Transplante de Rim , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Adulto , Idoso , Módulo de Elasticidade , Feminino , Humanos , Rim/diagnóstico por imagem , Rim/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Transplante Homólogo
4.
Kidney Int ; 97(2): 414-420, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31874802

RESUMO

Here we assessed the diagnostic value of a quantitative multiparametric magnetic resonance imaging (mpMRI) protocol for evaluation of renal allograft dysfunction with fibrosis. Twenty-seven renal transplant patients, including 15 with stable functional allografts (eGFR mean 71.5 ml/min/1.73m2), and 12 with chronic dysfunction/established fibrosis (eGFR mean 30.1 ml/min/1.73m2), were enrolled in this prospective single-center study. Sixteen of the patients had renal biopsy (mean 150 days) before the MRI. All patients underwent mpMRI at 1.5T including intravoxel-incoherent motion diffusion-weighted imaging, diffusion tensor imaging, blood oxygen level dependent (BOLD R2*) and T1 quantification. True diffusion D, pseudodiffusion D*, perfusion fraction PF, apparent diffusion coefficient (ADC), fractional anisotropy (FA), R2* and T1 were calculated for cortex and medulla. ΔT1 was calculated as (100x(T1 Cortex-T1 Medulla)/T1 Cortex). Test-retest repeatability and inter-observer reproducibility were assessed in four and ten patients, respectively. mpMRI parameters had substantial test-retest and interobserver repeatability (coefficient of variation under 15%), except for medullary PF and D* (coefficient of variation over 25%). Cortical ADC, D, medullary ADC and ΔT1 were all significantly decreased, while cortical T1 was significantly elevated in fibrotic allografts. Cortical T1 showed positive correlation to the Banff fibrosis and tubular atrophy scores. The combination of ΔT1 and cortical ADC had excellent cross-validated diagnostic performance for detection of chronic dysfunction with fibrosis. Cortical ADC and T1 had good performance for predicting eGFR decline at 18 months (4 or more ml/min/1.73m2/year). Thus, the combination of cortical ADC and T1 measurements shows promising results for the non-invasive assessment of renal allograft histology and outcomes.


Assuntos
Transplante de Rim , Imageamento por Ressonância Magnética Multiparamétrica , Imagem de Tensor de Difusão , Fibrose , Humanos , Transplante de Rim/efeitos adversos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Reprodutibilidade dos Testes
5.
Cancer Imaging ; 19(1): 29, 2019 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-31142363

RESUMO

PURPOSE: To assess the predictive value of volumetric apparent diffusion coefficient (vADC) histogram quantification obtained before and 6 weeks (6w) post-treatment for assessment of hepatocellular carcinoma (HCC) response to 90Yttrium radioembolization (RE). METHODS: In this retrospective study, 22 patients (M/F 15/7, mean age 65y) who underwent lobar RE were included between October 2013 and November 2014. All patients underwent routine liver MRI pre-treatment and 6w after RE. Two readers assessed index tumor response at 6 months after RE in consensus, using mRECIST criteria. vADC histogram parameters of index tumors at baseline and 6w, and changes in vADC (ΔvADC) histogram parameters were calculated. The predictive value of ADC metrics was assessed by logistic regression with stepwise parameter selection and ROC analyses. RESULTS: Twenty two HCC lesions (mean size 3.9 ± 2.9 cm, range 1.2-12.3 cm) were assessed. Response at 6 months was as follows: complete response (CR, n = 6), partial response (PR, n = 3), stable disease (SD, n = 12) and progression (PD, n = 1). vADC median/mode at 6w (1.81-1.82 vs. 1.29-1.35 × 10- 3 mm2/s) and ΔvADC median/max (27-44% vs. 0-10%) were significantly higher in CR/PR vs. SD/PD (p = 0.011-0.036), while there was no significant difference at baseline. Logistic regression identified vADC median at 6w as an independent predictor of response (CR/PR) with odds ratio (OR) of 3.304 (95% CI: 1.099-9.928, p = 0.033) and AUC of 0.77. ΔvADC mean was identified as an independent predictor of CR with OR of 4.153 (95%CI: 1.229-14.031, p = 0.022) and AUC of 0.91. CONCLUSION: Diffusion histogram parameters obtained at 6w and early changes in ADC from baseline are predictive of subsequent response of HCCs treated with RE, while pre-treatment vADC histogram parameters are not. These results need confirmation in a larger study. TRIAL REGISTRATION: This retrospective study was IRB-approved and the requirement for informed consent was waived.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Neoplasias Hepáticas/diagnóstico por imagem , Compostos Radiofarmacêuticos/uso terapêutico , Radioisótopos de Ítrio/uso terapêutico , Adulto , Carcinoma Hepatocelular/radioterapia , Feminino , Humanos , Neoplasias Hepáticas/radioterapia , Masculino , Pessoa de Meia-Idade , Curva ROC
6.
Eur Radiol ; 29(2): 993-1002, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30019143

RESUMO

OBJECTIVES: To quantify intravoxel incoherent motion (IVIM)-DWI and dynamic contrast-enhanced (DCE)-MRI parameters in normal and abnormal ileal segments in Crohn's disease (CD) patients and to assess the association of these parameters with clinical and MRI-based measurements of CD activity. METHODS: In this prospective study, 27 CD patients (M/F 18/9, mean age 42 years) underwent MR enterography, including IVIM-DWI and DCE-MRI. IVIM-DWI and DCE-MRI parameters were quantified in normal and abnormal small bowel segments, the latter identified by the presence of inflammatory changes. MRI parameter differences between normal and abnormal bowel were tested using Wilcoxon signed-rank tests. IVIM-DWI and DCE-MRI parameters were correlated with clinical data (C-reactive protein, Harvey-Bradshaw Index), conventional MRI parameters (wall thickness, length of involvement) and MRI activity scores (MaRIA, Clermont). Diagnostic performance of (combined) parameters for differentiation between normal and abnormal bowel was determined using ROC analysis. RESULTS: The DCE-MRI parameters peak concentration Cpeak, upslope, area-under-the-curve at 60s (AUC60), Ktrans and ve were significantly increased (p<0.023), while IVIM-DWI parameters perfusion fraction (PF) and ADC were significantly decreased (p<0.001) in abnormal bowel segments. None of the DCE-MRI and IVIM-DWI parameters correlated with clinical parameters (p>0.105). DCE-MRI parameters exhibited multiple significant correlations with wall thickness (Cpeak, upslope, AUC60, Ktrans; r range 0.431-0.664, p<0.025) and MaRIA/Clermont scores (Cpeak, AUC60, Ktrans; r range 0.441-0.617, p<0.021). Combined Ktrans+ve+PF+ADC showed highest AUC (0.963) for differentiation between normal and abnormal bowel, while ADC performed best for individual parameters (AUC=0.800). CONCLUSIONS: DCE-MRI and IVIM-DWI, particularly when used in combination, are promising for non-invasive evaluation of small bowel CD. KEY POINTS: • IVIM-DWI and DCE-MRI parameters were significantly different between normal and abnormal bowel segments in CD patients. • DCE-MRI parameters showed a significant association with wall thickness and MRI activity scores. • Combination of IVIM-DWI and DCE-MRI parameters led to the highest diagnostic performance for differentiation between normal and abnormal bowel segments, while ADC showed the highest diagnostic performance of individual parameters.


Assuntos
Doença de Crohn/diagnóstico por imagem , Adulto , Meios de Contraste , Difusão , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Íleo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Perfusão , Estudos Prospectivos , Curva ROC , Adulto Jovem
7.
J Magn Reson Imaging ; 48(4): 1091-1103, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29638020

RESUMO

BACKGROUND: Portal hypertension (PH), defined by hepatic venous pressure gradient (HVPG) ≥5 mmHg and clinically significant PH, defined by HVPG ≥10 mmHg, are complications of chronic liver disease. PURPOSE: To assess the diagnostic performance of MR elastography (MRE) and dynamic contrast-enhanced MRI (DCE-MRI) of the liver and spleen for the prediction of PH and clinically significant PH, in comparison with a qualitative PH imaging scoring system. STUDY TYPE: IRB-approved prospective study. POPULATION: In all, 34 patients with chronic liver disease who underwent HVPG measurement. FIELD STRENGTH/SEQUENCE: 1.5/3T examination including 2D-GRE MRE (n = 33) and DCE-MRI of the liver/spleen (n = 28). ASSESSMENT: Liver and spleen stiffness were calculated from elastogram maps. DCE-MRI was analyzed using model-free parameters and pharmacokinetic modeling. Two observers calculated qualitative PH imaging scores based on routine images. STATISTICAL TESTS: Imaging parameters were correlated with HVPG. Receiver operating characteristic (ROC) analysis was performed for prediction of PH and clinically significant PH. RESULTS: There were significant correlations between DCE-MRI parameters (liver time-to-peak, r = 0.517 / P = 0.006, liver distribution volume, r = 0.494 / P = 0.009, liver upslope, r = -0.567 / P = 0.002), liver stiffness (r = 0.478 / P = 0.016), PH imaging score (r = 0.441 / P = 0.009), and HVPG. ROC analysis provided significant area under the ROC (AUROCs) for PH (liver upslope 0.765, liver stiffness 0.809, spleen volume/diameter 0.746-0.731, PH imaging score 0.756) and for clinically significant PH (liver and spleen perfusion parameters 0.733-0.776, liver stiffness 0.742, PH imaging score 0.742). The ratio of liver stiffness to liver upslope had the highest AUROC for diagnosing PH (0.903) and clinically significant PH (0.785). DATA CONCLUSION: These preliminary results suggest that the combination of liver stiffness and perfusion metrics provide excellent accuracy for diagnosing PH, and fair accuracy for clinically significant PH. Combined MRE and DCE-MRI outperformed qualitative imaging scores for prediction of PH. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;48:1091-1103.


Assuntos
Técnicas de Imagem por Elasticidade , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Baço/diagnóstico por imagem , Adulto , Idoso , Índice de Massa Corporal , Meios de Contraste , Doença Hepática Terminal/diagnóstico por imagem , Feminino , Veias Hepáticas/diagnóstico por imagem , Humanos , Hipertensão Portal/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Pressão na Veia Porta , Estudos Prospectivos , Curva ROC , Radiologia
8.
J Magn Reson Imaging ; 47(6): 1552-1561, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29193508

RESUMO

BACKGROUND: Multiparametric magnetic resonance imaging (mpMRI) combining different techniques such as MR elastography (MRE) has emerged as a noninvasive approach to diagnose and stage liver fibrosis with high accuracy allowing for anatomical and functional information. PURPOSE: To assess the diagnostic performance of mpMRI including qualitative and quantitative assessment of MRE, liver surface nodularity (LSN) measurement, hepatic enhancement ratios postgadoxetic acid, and serum markers (APRI, FIB-4) for the detection of liver fibrosis. STUDY TYPE: IRB-approved retrospective. SUBJECTS: Eighty-three adult patients. FIELD STRENGTH/SEQUENCE: 1.5T and 3.0T MR systems. MRE and T1 -weighted postgadoxetic acid sequences. ASSESSMENT: Two independent observers analyzed qualitative color-coded MRE maps on a scale of 0-3. Regions of interest were drawn to measure liver stiffness on MRE stiffness maps and on pre- and postcontrast T1 -weighted images to measure hepatic enhancement ratios. Software was used to generate LSN measurements. Histopathology was used as the reference standard for diagnosis of liver fibrosis in all patients. STATISTICAL TESTS: A multivariable logistic analysis was performed to identify independent predictors of liver fibrosis. Receiver operating characteristic (ROC) analysis evaluated the performance of each imaging technique for detection of fibrosis, in comparison with serum markers. RESULTS: Liver stiffness measured with MRE provided the strongest correlation with histopathologic fibrosis stage (r = 0.74, P < 0.001), and the highest diagnostic performance for detection of stages F2-F4, F3-F4, and F4 (areas under the curve [AUCs] of 0.87, 0.91, and 0.89, respectively, P < 0.001) compared to other methods. Qualitative assessment of MRE maps showed fair to good accuracy for detection of fibrosis (AUC range 0.76-0.84). Multivariable logistic analysis identified liver stiffness and FIB-4 as independent predictors of fibrosis with AUCs of 0.90 (F2-F4), 0.93 (F3-F4) and 0.92 (F4) when combined. DATA CONCLUSION: Liver stiffness measured with MRE showed the best performance for detection of liver fibrosis compared to LSN and gadoxetic acid uptake, with slight improvement when combined with FIB-4. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1552-1561.


Assuntos
Técnicas de Imagem por Elasticidade , Gadolínio DTPA/farmacocinética , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Humanos , Cirrose Hepática/sangue , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Variações Dependentes do Observador , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
9.
Eur J Radiol Open ; 4: 115-117, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28932768

RESUMO

Hepatocellular adenoma (HCA) is a benign liver tumor most frequently occurring in women using oral contraception. HCA develops in normal or nearly normal livers and is extremely rare in cirrhosis. The authors present magnetic resonance imaging and histopathologic findings in a 57-year-old man with liver cirrhosis and hepatic adenomatosis. As the differentiation between HCA and hepatocellular carcinoma (HCC) can be difficult with imaging, we would like to highlight the importance of ancillary findings such as the presence of iron on MRI, which can be observed in HCA.

10.
J Hepatol ; 67(6): 1213-1221, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28823713

RESUMO

BACKGROUND AND AIMS: This study evaluates the performance of various magnetic resonance imaging (MRI) response criteria for the prediction of complete pathologic necrosis (CPN) of hepatocellular carcinoma (HCC) post locoregional therapy (LRT) using explant pathology as a reference. METHODS: We included 61 patients (male/female 46/15; mean age 60years) who underwent liver transplantation after LRT with transarterial chemoembolization plus radiofrequency or microwave ablation (n=56), or 90Yttrium radioembolization (n=5). MRI was performed <90days before liver transplantation. Three independent readers assessed the following criteria: RECIST, EASL, modified RECIST (mRECIST), percentage of necrosis on subtraction images, and diffusion-weighted imaging (DWI), both qualitative (signal intensity) and quantitative (apparent diffusion coefficient [ADC]). The degree of necrosis was retrospectively assessed at histopathology. Intraclass correlation coefficient (ICC) and Cohen's kappa were used to assess inter-reader agreement. Logistic regression and receiver operating characteristic analyses were used to determine imaging predictors of CPN. Pearson correlation was performed between imaging criteria and pathologic degree of tumor necrosis. RESULTS: A total of 97HCCs (mean size 2.3±1.3cm) including 28 with CPN were evaluated. There was excellent inter-reader agreement (ICC 0.77-0.86, all methods). EASL, mRECIST, percentage of necrosis and qualitative DWI were all significant (p<0.001) predictors of CPN, while RECIST and ADC were not. EASL, mRECIST and percentage of necrosis performed similarly (area under the curves [AUCs] 0.810-0.815) while the performance of qualitative DWI was lower (AUC 0.622). Image subtraction demonstrated the strongest correlation (r=0.71-0.72, p<0.0001) with pathologic degree of tumor necrosis. CONCLUSIONS: EASL/mRECIST criteria and image subtraction have excellent diagnostic performance for predicting CPN in HCC treated with LRT, with image subtraction correlating best with pathologic degree of tumor necrosis. Thus, MR image subtraction is recommended for assessing HCC response to LRT. LAY SUMMARY: The assessment of hepatocellular carcinoma (HCC) tumor necrosis after locoregional therapy is essential for additional treatment planning and estimation of outcome. In this study, we assessed the performance of various magnetic resonance imaging (MRI) response criteria (RECIST, mRECIST, EASL, percentage of necrosis on subtraction images, and diffusion-weighted imaging) for the prediction of complete pathologic necrosis of HCC post locoregional therapy on liver explant. Patients who underwent liver transplantation after locoregional therapy were included in this retrospective study. All patients underwent routine liver MRI within 90days of liver transplantation. EASL/mRECIST criteria and image subtraction had excellent diagnostic performance for predicting complete pathologic necrosis in treated HCC, with image subtraction correlating best with pathologic degree of tumor necrosis.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Hepáticas/terapia , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Transplante de Fígado , Masculino , Pessoa de Meia-Idade , Necrose , Estudos Retrospectivos
11.
Abdom Radiol (NY) ; 42(6): 1685-1694, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28154910

RESUMO

PURPOSE: The aim of the study was to correlate tumor stiffness (TS) measured with MR elastography (MRE) with degree of tumor enhancement and necrosis on contrast-enhanced T1-weighted imaging (CE-T1WI) in hepatocellular carcinomas (HCC) treated with Yttrium-90 radioembolization (RE) or transarterial chemoembolization plus radiofrequency ablation (TACE/RFA). MATERIAL AND METHODS: This retrospective study was IRB-approved and the requirement for informed consent was waived. 52 patients (M/F 38/14, mean age 67 years) with HCC who underwent RE (n = 22) or TACE/RFA (n = 30) and 11 controls (M/F 6/5, mean age 64 years) with newly diagnosed untreated HCC were included. The MRI protocol included a 2D MRE sequence. TS and LS (liver stiffness) were measured on stiffness maps. Degree of tumor necrosis was assessed on subtraction images by two observers, and tumor enhancement ratios (ER) were calculated on CE-T1WI by one observer. RESULTS: 63 HCCs (mean size 3.2 ± 1.6 cm) were evaluated. TS was significantly lower in treated vs. untreated tumors (3.9 ± 1.8 vs. 6.9 ± 3.4 kPa, p = 0.006) and also compared to LS (5.3 ± 2.2 kPa, p = 0.002). There were significant correlations between TS and each of enhancement ratios (r = 0.514, p = 0.0001), and percentage of necrosis (r = -0.540, p = 0.0001). The observed correlations were stronger in patients treated with RE (TS vs. ER, r = 0.636, TS vs. necrosis, r = -0.711, both p = 0.0001). Percentage of necrosis and T1-signal in native T1WI were significant independent predictors of TS (p = 0.0001 and 0.001, respectively). CONCLUSION: TS measured with MRE shows a significant correlation with tumor enhancement and necrosis, especially in HCCs treated with RE.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Técnicas de Imagem por Elasticidade , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética/métodos , Idoso , Carcinoma Hepatocelular/patologia , Ablação por Cateter/métodos , Quimioembolização Terapêutica , Meios de Contraste , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Necrose , Estudos Retrospectivos , Técnica de Subtração , Resultado do Tratamento , Radioisótopos de Ítrio/uso terapêutico
12.
Eur Radiol ; 27(3): 1074-1080, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27368924

RESUMO

OBJECTIVES: To determine perfusion computed tomography (P-CT) findings for distinction of arterial pseudolesions (APL) from hepatocellular carcinoma (HCC) in the cirrhotic liver. METHODS: 32 APL and 21 HCC in 20 cirrhotic patients (15 men; 65 ± 10 years), who underwent P-CT for evaluation of HCC pre- (N = 9) or post- (N = 11) transarterial chemoembolization, were retrospectively included using CT follow-up as the standard of reference. All 53 lesions were qualitatively (visual) and quantitatively (perfusion parameters) analysed according to their shape (wedge, irregular, nodular), location (not-/adjunct to a fistula), arterial liver perfusion (ALP), portal venous liver perfusion (PLP), hepatic perfusion index (HPI). Accuracy for diagnosis of HCC was determined using receiver operating characteristics. RESULTS: 18/32 (56 %) APL were wedge shaped, 10/32 (31 %) irregular and 4/32 (12 %) nodular, while 11/21 (52 %) HCC were nodular or 10/21 (48 %) irregular, but never wedge shaped. Significant difference between APL and HCC was seen for lesion shape in pretreated lesions (P < 0.001), and for PLP and HPI in both pre- and post-treated lesions (all, P < 0.001). Diagnostic accuracy for HCC was best for combined assessment of lesion configuration and PLP showing an area under the curve of 0.901. CONCLUSION: Combined assessment of lesion configuration and portal venous perfusion derived from P-CT allows best to discriminate APL from HCC with high diagnostic accuracy. KEY POINTS: • Arterio-portal shunting is common in the cirrhotic liver, especially after local treatment. • Arterial pseudolesions (APL) due to shunting might mimic hepatocellular carcinoma (HCC). • Perfusion-CT allows for qualitative and quantitative assessment of liver lesions. • Lesion configuration fails to discriminate APL from HCC in locally treated patients. • Integration of quantitative perfusion analysis improves accuracy for diagnosis of HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
Radiology ; 280(1): 78-87, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26824712

RESUMO

Purpose To develop a dual-energy contrast media-enhanced computed tomographic (CT) protocol by using time-attenuation curves from previously acquired perfusion CT data and to evaluate prospectively the relationship between iodine enhancement metrics at dual-energy CT and perfusion CT parameters in patients with hepatocellular carcinoma (HCC). Materials and Methods Institutional review board and local ethics committee approval and written informed consent were obtained. The retrospective part of this study included the development of a dual-energy CT contrast-enhanced protocol to evaluate peak arterial enhancement of HCC in the liver on the basis of time-attenuation curves from previously acquired perfusion CT data in 20 patients. The prospective part of the study consisted of an intraindividual comparison of dual-energy CT and perfusion CT data in another 20 consecutive patients with HCC. Iodine density and iodine ratio (iodine attenuation of the lesion divided by iodine attenuation in the aorta) from dual-energy CT and arterial perfusion (AP), portal venous perfusion, and total perfusion (TP) from perfusion CT were compared. Pearson R and linear correlation coefficients were calculated for AP and iodine density, AP and iodine ratio, TP and iodine density, and TP and iodine ratio. Results The dual-energy CT protocol consisted of bolus tracking in the abdominal aorta (threshold, 150 HU; scan delay, 9 seconds). The strongest intraindividual correlations in HCCs were found between iodine density and AP (r = 0.75, P = .0001). Moderate correlations were found between iodine ratio and AP (r = 0.50, P = .023) and between iodine density and TP (r = 0.56, P = .011). No further significant correlations were found. The volume CT dose index (11.4 mGy) and dose-length product (228.0 mGy · cm) of dual-energy CT was lower than those of the arterial phase of perfusion CT (36.1 mGy and 682.3 mGy · cm, respectively). Conclusion A contrast-enhanced dual-energy CT protocol developed by using time-attenuation curves from previously acquired perfusion CT data sets in patients with HCC could show good correlation between iodine density from dual-energy CT with AP from perfusion CT. (©) RSNA, 2016.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos
14.
Cardiovasc Intervent Radiol ; 39(3): 400-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26216725

RESUMO

PURPOSE: To evaluate in patients with hepatocellular carcinoma (HCC), whether assessment of tumor heterogeneity by histogram analysis of computed tomography (CT) perfusion helps predicting response to transarterial radioembolization (TARE). MATERIALS AND METHODS: Sixteen patients (15 male; mean age 65 years; age range 47-80 years) with HCC underwent CT liver perfusion for treatment planning prior to TARE with Yttrium-90 microspheres. Arterial perfusion (AP) derived from CT perfusion was measured in the entire tumor volume, and heterogeneity was analyzed voxel-wise by histogram analysis. Response to TARE was evaluated on follow-up imaging (median follow-up, 129 days) based on modified Response Evaluation Criteria in Solid Tumors (mRECIST). Results of histogram analysis and mean AP values of the tumor were compared between responders and non-responders. Receiver operating characteristics were calculated to determine the parameters' ability to discriminate responders from non-responders. RESULTS: According to mRECIST, 8 patients (50%) were responders and 8 (50%) non-responders. Comparing responders and non-responders, the 50th and 75th percentile of AP derived from histogram analysis was significantly different [AP 43.8/54.3 vs. 27.6/34.3 mL min(-1) 100 mL(-1)); p < 0.05], while the mean AP of HCCs (43.5 vs. 27.9 mL min(-1) 100 mL(-1); p > 0.05) was not. Further heterogeneity parameters from histogram analysis (skewness, coefficient of variation, and 25th percentile) did not differ between responders and non-responders (p > 0.05). If the cut-off for the 75th percentile was set to an AP of 37.5 mL min(-1) 100 mL(-1), therapy response could be predicted with a sensitivity of 88% (7/8) and specificity of 75% (6/8). CONCLUSION: Voxel-wise histogram analysis of pretreatment CT perfusion indicating tumor heterogeneity of HCC improves the pretreatment prediction of response to TARE.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Fígado/diagnóstico por imagem , Compostos Radiofarmacêuticos/uso terapêutico , Radioisótopos de Ítrio/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Interpretação Estatística de Dados , Feminino , Humanos , Fígado/irrigação sanguínea , Fígado/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Microesferas , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
15.
Eur Radiol ; 26(2): 459-68, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26037718

RESUMO

PURPOSE: To evaluate the potential of advanced modeled iterative reconstruction (ADMIRE) for optimizing radiation dose of high-pitch coronary CT angiography (CCTA). METHODS: High-pitch 192-slice dual-source CCTA was performed in 25 patients (group 1) according to standard settings (ref. 100 kVp, ref. 270 mAs/rot). Images were reconstructed with filtered back projection (FBP) and ADMIRE (strength levels 1-5). In another 25 patients (group 2), high-pitch CCTA protocol parameters were adapted according to results from group 1 (ref. 160 mAs/rot), and images were reconstructed with ADMIRE level 4. In ten patients of group 1, vessel sharpness using full width at half maximum (FWHM) analysis was determined. Image quality was assessed by two independent, blinded readers. RESULTS: Interobserver agreements for attenuation and noise were excellent (r = 0.88/0.85, p < 0.01). In group 1, ADMIRE level 4 images were most often selected (84%, 21/25) as preferred data set; at this level noise reduction was 40% compared to FBP. Vessel borders showed increasing sharpness (FWHM) at increasing ADMIRE levels (p < 0.05). Image quality in group 2 was similar to that of group 1 at ADMIRE levels 2-3. Radiation dose in group 2 (0.3 ± 0.1 mSv) was significantly lower than in group 1 (0.5 ± 0.3 mSv; p < 0.05). CONCLUSIONS: In a selected population, ADMIRE can be used for optimizing high-pitch CCTA to an effective dose of 0.3 mSv. KEY POINTS: • Advanced modeled IR (ADMIRE) reduces image noise up to 50% as compared to FBP. • Coronary artery vessel borders show an increasing sharpness at higher ADMIRE levels. • High-pitch CCTA with ADMIRE is possible at a radiation dose of 0.3 mSv.


Assuntos
Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos
16.
Invest Radiol ; 50(10): 695-702, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26002623

RESUMO

OBJECTIVE: To determine the value of advanced virtual monoenergetic images (mono+) from dual-energy computed tomography (CT) of hyperattenuating and hypoattenuating liver lesions in various phantom sizes and patients in comparison with standard monoenergetic images (mono). MATERIALS AND METHODS: Anthropomorphic phantoms simulating 4 patient sizes (S, 300 × 200 mm; M, 350 × 250 mm; L, 400 × 300 mm; and XL, 600 × 450 mm) with a liver insert containing both hyperattenuating and hypoattenuating iodine-containing lesions were imaged with dose-equivalent dual-energy (100/150 Sn kilovolt [peak] [kV{p}]) and single-energy (120 kV[p]) protocols on a 192-slice dual-source CT system. In addition, 4 patients with 3 hypoattenuating and 3 hyperattenuating hepatocellular carcinoma were included and underwent dual-energy CT imaging with the same scanner at similar kV(p) settings (100/150 Sn kV[p]). Images were reconstructed with standard mono and with the mono+ algorithm at 10-kiloelectron volt (keV) intervals from 40 to 190 keV. Attenuation of the liver and lesions were measured, and contrast-to-noise ratios (CNRs) were calculated. Lesion conspicuity was rated by 2 blinded independent readers in all mono and mono+ data sets from 40 to 190 keV using a 5-point Likert scale (1, lowest conspicuity; and 5, highest conspicuity). RESULTS: Attenuation in the liver and in both hyperattenuating and hypoattenuating lesions did not differ between mono and mono+ (P = 0.41-0.49). Noise on mono+ was significantly lower than on mono for all phantom sizes (P < 0.05) and was increasing with phantom size. Hyperattenuating lesion CNR was highest for mono+ images at 40 keV in the S phantom (6.73), with significantly higher CNR for mono+ than for mono and for single energy (120 kV[p]) in all phantom sizes (all P < 0.001) except for the XL phantom. Hypoattenuating lesion CNR was highest for high-keV mono+ being significantly higher than on mono and on single-energy (120 kV[p]) images (all P < 0.001), except for the XL phantom with significantly higher CNR for mono (1.3) compared with mono+ (0.47) and 120 kV(p) (1.26). In patients, CNR curves of hyperattenuating hepatocellular carcinoma were in accordance with the phantom data, whereas hypoattenuating lesions demonstrate varying curves, some being in accordance with findings in phantoms. Interreader agreement for lesion conspicuity was very good (intraclass correlation, 0.95), with higher conspicuity scores for mono+ than for mono and single energy (120 kV[p]) at all phantom sizes (all P < 0.05) and within patients. CONCLUSION: Our ex vivo and patient data demonstrate added value for imaging of both hyperattenuating and hypoattenuating liver lesions with advanced virtual monoenergetic dual-energy CT by decreased noise, increased CNR, and higher lesion conspicuity, although with limitations in XL body sizes.


Assuntos
Tamanho Corporal , Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
17.
Eur Radiol ; 25(8): 2346-53, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25693663

RESUMO

OBJECTIVE: To assess radiation dose and image quality in body CT-angiography (CTA) with automated attenuation-based tube voltage selection (ATVS) on a 192-slice dual-source CT (DSCT). METHODS: Forty patients (69.5 ± 9.6 years) who had undergone body CTA with ATVS (ref.kVp 100, ref.mAs 90) using a 2x192-slice CT in single-source mode were retrospectively included. All patients had undergone prior CTA with a 2x128-slice CT and ATVS with identical imaging and contrast media protocols, serving for comparison. Images were reconstructed with iterative reconstruction at similar strength levels. Radiation dose was determined. Image quality was assessed semi-quantitatively (1:excellent, 5:non-diagnostic), aortic attenuation, noise and CNR were determined. RESULTS: As compared to 128-slice DSCT, 192-slice DSCT selected tube voltages were lower in 30 patients (75 %), higher in 3 (7.5 %), and similar in 7 patients (17.5 %). CTDIvol was lower with 192-slice DSCT (4.7 ± 1.9 mGy vs. 5.8 ± 2.1 mGy; p < 0.001). Subjective image quality, mean aortic attenuation (342 ± 67HU vs. 268 ± 67HU) and CNR (9.8 ± 2.5 vs. 8.2 ± 2.9) were higher with 192-slice DSCT (all p < 0.01), all datasets being diagnostic. CONCLUSION: Our study suggests that ATVS of 192-slice DSCT for body CTA is associated with an improved image quality and further radiation dose reduction of 19 % compared to 128-slice DSCT. KEY POINTS: • 192-slice DSCT allows imaging from 70 kVp to 150 kVp at 10 kVp increments. • 192-slice DSCT allows for radiation-dose reduction in body-CTA with ATVS. • Subjective and objective image quality increase compared to 128-slice DSCT.


Assuntos
Angiografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Estudos Retrospectivos
18.
Int J Cardiovasc Imaging ; 31(1): 135-42, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25119889

RESUMO

To investigate the use of computed tomography (CT) to measure the mitral valve annulus size before implantation of a percutaneous mitral valve annuloplasty device in an animal trial. Seven domestic pigs underwent CT before and after implantation of a Cardioband™ (a percutaneously implantable mitral valve annuloplasty device) with a second-generation 128-section dual-source CT machine. Implantation of the Cardioband™ was performed in a standard fashion according to a protocol. Animals were sacrificed afterwards and the hearts explanted. The Cardioband™ was found to be adequately implanted in all animals, with no anchor dehiscence and no damage of the circumflex artery (CX) or the coronary sinus (CS). The correct length of the band as chosen according to the length of the posterior mitral annulus measured in CT before implantation was confirmed in gross examination in all animals. The device did not result in a metal artifact-related degradation of image quality. The closest distance from the closest anchor to the CX was 2.1 ± 0.7 mm in diastole and 1.6 ± 0.5 mm systole. Mitral annulus distance to the CS was 6.4 ± 1.3 mm in diastole and 7.7 ± 1.1 mm in systole. CT visualization and measurement of the mitral valve annulus dimensions is feasible and can become the imaging method of choice for procedure planning of Cardioband™ implantations or other transcatheter mitral annuloplasty devices.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Anuloplastia da Valva Mitral/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Tomografia Computadorizada Multidetectores , Cirurgia Assistida por Computador/métodos , Animais , Estudos de Viabilidade , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Modelos Animais , Valor Preditivo dos Testes , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador , Cirurgia Assistida por Computador/instrumentação , Sus scrofa
20.
Int J Cardiovasc Imaging ; 30(6): 1173-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24816910

RESUMO

To determine the average heart rate (HR) and heart rate variability (HRV) required for diagnostic imaging of the coronary arteries in patients undergoing high-pitch CT-angiography (CTA) with third-generation dual-source CT. Fifty consecutive patients underwent CTA of the thoracic (n = 8) and thoracoabdominal (n = 42) aorta with third-generation dual-source 192-slice CT with prospective electrocardiography (ECG)-gating at a pitch of 3.2. No ß-blockers were administered. Motion artifacts of coronary arteries were graded on a 4-point scale. Average HR and HRV were noted. The average HR was 66 ± 11 beats per minute (bpm) (range 45-96 bpm); the HRV was 7.3 ± 4.4 bpm (range 3-20 bpm). Interobserver agreement on grade of image quality for the 642 coronary segments evaluated by both observers was good (κ = 0.71). Diagnostic image quality was found for 608 of the 642 segments (95%) in 43 of 50 patients (86%). In 14% of the patients, image quality was nondiagnostic for at least one segment. HR (p = 0.001) was significantly higher in patients with at least one non-diagnostic segment compared to those without. There was no significant difference (p > 0.05) in HRV between patients with nondiagnostic segments and those with diagnostic images of all segments. All patients with a HR < 70 bpm had diagnostic image quality in all coronary segments. The effective radiation dose and scan time for the heart were 0.4 ± 0.1 mSv and 0.17 ± 0.02 s, respectively. Third-generation dual-source 192-slice CT allows for coronary angiography in the prospectively ECG-gated high-pitch mode with diagnostic image quality at HR up to 70 bpm. HRV is not significantly related to image quality of coronary CTA.


Assuntos
Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Frequência Cardíaca , Tomografia Computadorizada Multidetectores , Idoso , Artefatos , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Variações Dependentes do Observador , Valor Preditivo dos Testes , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...