Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Orthop Relat Res ; 469(4): 1103-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21161739

RESUMO

BACKGROUND: Appraisal of the orientation of implants in THA dislocations currently is based on imaging done with the patient in the supine position. However, dislocation occurs in standing or sitting positions. Whether measured anteversion differs in images projected in the position of dislocation is unclear. QUESTIONS/PURPOSES: We compared measured acetabular cup orientations on axial CT scans taken with the patient in a supine position with those from CT sections at angles to the sacral slope reflecting standing and sitting positions. METHODS: We retrospectively reviewed the radiographs of 328 asymptomatic patients who had THAs. Anatomic acetabular anteversion (AAA) was measured from the plain CT scan (supine position, axial CT sections). The AAA also was measured on reformatted CT scans in which the orientation was adjusted individually to the sacral slope on lateral radiographs with patients in the standing and sitting positions. RESULTS: The mean/(SD) AAA changed from 24.2° (6.9°) in the supine position to 31.7° (5.6°) and 38.8° (5.4°) in simulated standing and sitting positions, respectively. The supine AAA correlated with the standing AAA (r = 0.857) but not with the sitting AAA (r = 0.484). CONCLUSIONS: These data suggest measurement of the AAA on a plain CT scan used in current practice is biased. In patients with recurrent posterior dislocation from a sitting position, accounting for the functional variations in measurement of the position of the acetabular cup provides more relevant information regarding component positioning.


Assuntos
Acetábulo/diagnóstico por imagem , Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/diagnóstico por imagem , Posicionamento do Paciente , Decúbito Dorsal , Tomografia Computadorizada por Raios X , Idoso , Artroplastia de Quadril/instrumentação , Feminino , França , Luxação do Quadril/etiologia , Prótese de Quadril , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
2.
Hip Int ; 19(3): 257-63, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19876881

RESUMO

The acetabular anteversion angle varies according to the position of the pelvis. The objective goal of our study was to investigate changes in pelvic orientation after total hip replacement for primary osteoarthritis. We studied 89 patients who underwent total hip replacement for primary unilateral osteoarthritis. Lateral pelvic X-rays that included the hips were performed pre-operatively and one year post-operatively. Reference values were calculated by carrying out the same analysis in 100 asymptomatic healthy volunteers. Pelvic orientation was analyzed using the sacral slope. Patients having surgery for osteoarthritis had a decreased pelvic range of motion pre-operatively and post-operatively when compared to healthy volunteers. Post-operatively, this range of motion increased by 3 degrees but remained lower than the norm. Compared to asymptomatic healthy volunteers, patients affected by osteoarthritis had a posterior pelvic extension that decreased post-operatively but did not return to norm. This post-operative pelvic inclination generates a significant decrease in the final cup anteversion and thus may predispose to posterior dislocation. As this post-operative alteration to pelvic orientation cannot be anticipated, computer-aided surgery for cup positioning may not improve the accuracy of the acetabular anteversion in some patients.


Assuntos
Artroplastia de Quadril/efeitos adversos , Articulação do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia , Ossos Pélvicos/diagnóstico por imagem , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/anatomia & histologia , Radiografia , Recuperação de Função Fisiológica , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...