Mater Sci Eng C Mater Biol Appl ; 61: 574-8, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-26838885

RESUMO

ß-type titanium alloys are promising materials in the field of medical implants. The effect of ß-phase stability on the mechanical properties, corrosion resistance and cytotoxicity of a newly designed ß-type (Ti77Nb17Ta6) biocompatible alloys are studied. The ß-phase stability was controlled by the addition of small quantities of Fe and O. X-ray diffraction and microstructural analysis showed that the addition of O and Fe stabilized the ß-phase in the treated solution condition. The strength and hardness have increased with the increase in ß-phase stability while ductility and Young's modulus have decreased. The potentio-dynamic polarization tests showed that the corrosion resistance of the new alloys is better than Ti-6Al-4V alloy by at least ten times. Neutral red uptake assay cytotoxicity test showed cell viability of at least 95%. The new alloys are promising candidates for biomedical applications due to their high mechanical properties, corrosion resistance, and reduced cytotoxicity.


Assuntos
Ligas , Teste de Materiais , Nióbio , Tantálio , Titânio , Ligas/química , Ligas/farmacologia , Dureza , Células HeLa , Humanos , Nióbio/química , Nióbio/farmacologia , Tantálio/química , Tantálio/farmacologia , Titânio/química , Titânio/farmacologia