Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Clin Electrophysiol ; 9(10): 2054-2066, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37715740

RESUMO

BACKGROUND: Substrate abnormalities can alter atrial activation during atrial tachycardias (ATs) thereby influencing AT-wave morphology on the surface electrocardiogram. OBJECTIVES: This study sought to identify determinants of isoelectric intervals during ATs with complex atrial activation patterns. METHODS: High-density activation maps of 126 ATs were studied. To assess the impact of the activated atrial surface on the presence of isoelectric intervals, this study measured the minimum activated area throughout the AT cycle, defined as the smallest activated area within a 50-millisecond period, by using signal processing algorithms (LUMIPOINT). RESULTS: ATs with isoelectric intervals (P-wave ATs) included 23 macro-re-entrant ATs (40%), 26 localized-re-entrant ATs (46%), and 8 focal ATs (14%), whereas those without included 46 macro-re-entrant ATs (67%), 21 localized-re-entrant ATs (30%), and 2 focal ATs (3%). Multivariable regression identified smaller minimum activated area and larger very low voltage area as independent predictors of P-wave ATs (OR: 0.732; 95% CI: 0.644-0.831; P < 0.001; and OR: 1.042; 95% CI: 1.006-1.080; P = 0.023, respectively). The minimum activated area with the cutoff value of 10 cm2 provided the highest predictive accuracy for P-wave ATs with sensitivity, specificity, and positive and negative predictive values of 96%, 97%, 97%, and 95%, respectively. In re-entrant ATs, smaller minimum activated area was associated with lower minimum conduction velocity within the circuit and fewer areas of delayed conduction outside of the circuit (standardized ß: 0.524; 95% CI: 0.373-0.675; P < 0.001; and standardized ß: 0.353; 95% CI: 0.198-0.508; P < 0.001, respectively). CONCLUSIONS: Reduced atrial activation area and voltage were associated with isoelectric intervals during ATs.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Eletrocardiografia
2.
Circ Arrhythm Electrophysiol ; 16(10): e012241, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37728002

RESUMO

BACKGROUND: Abnormal atrial potentials (AAPs) recorded during sinus rhythm/atrial pacing may indicate areas of slow conduction capable of supporting reentrant atrial tachycardia (AT). Therefore, we sought to examine the relationship between AAPs and AT circuits. METHODS: One hundred twenty-three reentrant ATs in 104 patients were analyzed. AAPs, consisting of fragmented potentials and split potentials, were assessed using the Rhythmia LUMIPOINT algorithm. RESULTS: There was 93±13% overlap between areas with AAPs during sinus rhythm/atrial pacing and areas of slow conduction along the reentry circuit during AT. The cumulative area of AAPs was smaller in patients with localized-reentrant ATs compared with anatomic macro-reentrant ATs (20.0 [14.6-30.5] versus 28.9 [21.8-35.6] cm2; P=0.021). Patients with perimitral ATs had larger areas of AAPs on the lateral wall whereas patients with roof-dependent ATs had larger areas of AAPs on the roof and posterior wall (P≤0.018 for all comparisons). The patchy scar that was associated with localized-reentrant AT exhibited a larger area of AAPs at its periphery than the scar that did not participate in localized-reentrant AT (3.1 [2.4-4.5] versus 1.0 [0.7-1.6] cm2; P<0.001). CONCLUSIONS: AAPs recorded during sinus rhythm/atrial pacing are associated with areas of slow conduction during reentrant AT. The burden and distribution of AAPs may provide actionable insights into AT circuit features, including in cases in which ATs are difficult to map.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz , Átrios do Coração , Frequência Cardíaca , Estimulação Cardíaca Artificial
3.
J Cardiovasc Electrophysiol ; 33(5): 908-916, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35274776

RESUMO

INTRODUCTION: Due to changes in esophageal position, preoperative assessment of the esophageal location may not mitigate the risk of esophageal injury in catheter ablation for atrial fibrillation (AF). This study aimed to assess esophageal motion and its impact on AF ablation strategies. METHODS AND RESULTS: Ninety-seven AF patients underwent two computed tomography (CT) scans. The area at risk of esophageal injury (AAR) was defined as the left atrial surface ≤3 mm from the esophagus. On CT1, ablation lines were drawn blinded to the esophageal location to create three ablation sets: individual pulmonary vein isolation (PVI), wide antral circumferential ablation (WACA), and WACA with linear ablation (WACA + L). Thereafter, ablation lines for WACA and WACA + L were personalized to avoid the AAR. Rigid registration was performed to align CT1 onto CT2, and the relationship between ablation lines and the AAR on CT2 was analyzed. The esophagus moved by 3.6 [2.7 to 5.5] mm. The AAR on CT2 was 8.6 ± 3.3 cm2 , with 77% overlapping that on CT1. High body mass index was associated with the AAR mismatch (standardized ß 0.382, p < .001). Without personalization, AARs on ablation lines for individual PVI, WACA, and WACA + L were 0 [0-0.4], 0.8 [0.5-1.2], and 1.7 [1.2-2.0] cm2 . Despite the esophageal position change, the personalization of ablation lines for WACA and WACA + L reduced the AAR on lines to 0 [0-0.5] and 0.7 [0.3-1.0] cm2 (p < .001 for both). CONCLUSION: The personalization of ablation lines based on a preoperative CT reduced ablation to the AAR despite changes in esophageal position.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Esôfago/lesões , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 33(6): 1116-1124, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35347799

RESUMO

INTRODUCTION: The optimal strategy after a failed ablation for persistent atrial fibrillation (perAF) is unknown. This study evaluated the value of an anatomically guided strategy using a systematic set of linear lesions with adjunctive ethanol infusion into the vein of Marshall (Et-VOM) in patients referred for second perAF ablation procedures. METHODS AND RESULTS: Patients with perAF who underwent a second procedure were grouped according to the two strategies. The first strategy was an anatomically guided approach using systematic linear ablation with adjunctive Et-VOM, with bidirectional blocks at the posterior mitral isthmus (MI), roof, and cavotricuspid isthmus (CTI) as the procedural endpoint (Group I). The second one was an electrophysiology-guided strategy, with atrial tachyarrhythmia termination as the procedural endpoint (Group II). Arrhythmia behavior during the procedure guided the ablation strategy. Groups I and II consisted of 96 patients (65 ± 9 years; 71 men) and 102 patients (63 ± 10 years; 83 men), respectively. Baseline characteristics were comparable. In Group I, Et-VOM was successfully performed in 91/96 (95%), and procedural endpoint (bidirectional block across all three anatomical lines) was achieved in 89/96 (93%). In Group II, procedural endpoint (atrial tachyarrhythmia termination) was achieved in 80/102 (78%). One-year follow-up demonstrated Group I (21/96 [22%]) experienced less recurrence compared to Group II (38/102 [37%], Log-rank p = .01). This was driven by lower AT recurrence in Group I (Group I: 10/96 [10%] vs. Group II: 29/102 [28%]; p = .002). CONCLUSION: Anatomically guided strategy with adjunctive Et-VOM is superior to an electrophysiology-guided strategy for second procedures in patients with perAF at 1-year follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Eletrofisiologia Cardíaca , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Etanol/efeitos adversos , Humanos , Masculino , Veias Pulmonares/cirurgia , Recidiva , Taquicardia , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 32(8): 2216-2224, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34223662

RESUMO

INTRODUCTION: Ultrahigh-density mapping for ventricular tachycardia (VT) is increasingly used. However, manual annotation of local abnormal ventricular activities (LAVAs) is challenging in this setting. Therefore, we assessed the accuracy of the automatic annotation of LAVAs with the Lumipoint algorithm of the Rhythmia system (Boston Scientific). METHODS AND RESULTS: One hundred consecutive patients undergoing catheter ablation of scar-related VT were studied. Areas with LAVAs and ablation sites were manually annotated during the procedure and compared with automatically annotated areas using the Lumipoint features for detecting late potentials (LP), fragmented potentials (FP), and double potentials (DP). The accuracy of each automatic annotation feature was assessed by re-evaluating local potentials within automatically annotated areas. Automatically annotated areas matched with manually annotated areas in 64 cases (64%), identified an area with LAVAs missed during manual annotation in 15 cases (15%), and did not highlight areas identified with manual annotation in 18 cases (18%). Automatic FP annotation accurately detected LAVAs regardless of the cardiac rhythm or scar location; automatic LP annotation accurately detected LAVAs in sinus rhythm, but was affected by the scar location during ventricular pacing; automatic DP annotation was not affected by the mapping rhythm, but its accuracy was suboptimal when the scar was located on the right ventricle or epicardium. CONCLUSION: The Lumipoint algorithm was as/more accurate than manual annotation in 79% of patients. FP annotation detected LAVAs most accurately regardless of mapping rhythm and scar location. The accuracy of LP and DP annotations varied depending on mapping rhythm or scar location.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia
6.
J Cardiovasc Electrophysiol ; 32(9): 2451-2461, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34314087

RESUMO

INTRODUCTION: Human atria comprise distinct layers. One layer can bypass another, and lead to a downstream centrifugal propagation at their interface. We sought to characterize anatomical substrates, electrophysiological properties, and ablation outcomes of "pseudo-focal" atrial tachycardias (ATs), defined as macroreentrant ATs mimicking focal ATs. METHODS AND RESULTS: We retrospectively analyzed left atrial ATs showing centrifugal propagation with postpacing intervals (PPIs) after entrainment pacing suggestive of a macroreentrant mechanism. A total of 22 patients had pseudo-focal ATs consisting of 15 perimitral and 7 roof-dependent flutters. A low-voltage area was consistently found at the collision site and colocalized with distinct anatomical structures like the: (1) coronary sinus-great cardiac vein bundle (27%), (2) vein of Marshall bundle (18%), (3) Bachmann bundle (27%), (4) septopulmonary bundle (18%), and (5) fossa ovalis (9%). The mean missing tachycardia cycle length (TCL) was 65 ± 31 ms (22%) on the endocardial activation map. PPI was 0 [0-15] ms and 0 [0-21] ms longer than TCL at the breakthrough site and the opposite site, respectively. While feasible in 21 pseudo-focal ATs (95%), termination was better achieved by blocking the anatomical isthmus than ablating the breakthrough site [20/21 (95%) vs. 1/5 (20%); p < .001]. CONCLUSION: Perimitral and roof-dependent flutters with centrifugal propagation are favored by a low-voltage area located at well-identified anatomical structures. Comprehensive entrainment pacing maneuvers are crucial to distinguish pseudo-focal ATs from true focal ATs. Blocking the anatomical isthmus is a better therapeutic option than ablating the breakthrough site.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Supraventricular , Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Humanos , Estudos Retrospectivos , Taquicardia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
7.
Heart Rhythm ; 18(11): 1951-1958, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34217842

RESUMO

BACKGROUND: Mitral isthmus gaps have been ascribed to an epicardial musculature anatomically related to the great cardiac vein (GCV) and the vein of Marshall (VOM). Their lumen offers an access for radiofrequency application or ethanol infusion, respectively. OBJECTIVE: The purpose of this study was to evaluate the frequency of mitral isthmus gaps accessible via the GCV lumen, to assess their location around the GCV circumference, and to propose an efficient ablation strategy when present. METHODS: One hundred consecutive patients underwent VOM ethanol infusion (step 1) and endocardial linear ablation from the mitral annulus to the left inferior pulmonary vein (step 2). In cases of mitral isthmus gap, endovascular ablation of the GCV anchored wall facing the left atrium was systematically performed (step 3), while the opposite GCV free wall was targeted in case of block failure only (step 4). RESULTS: After VOM ethanol infusion and endocardial ablation, mitral isthmus block occurred in 51 patients (51%). Pacing maneuvers and activation sequences demonstrated an epicardial gap via the VOM in 2 patients (2%) and via the GCV in 47 patients (47%). In the latter case, block was achieved at the GCV anchored wall in 42 patients (89%) and the GCV free wall in 5 patients (11%). Global success rate of mitral isthmus block was 98%. No tamponade occurred. CONCLUSION: With the advent of VOM ethanol infusion, residual mitral isthmus gaps are mostly eliminated within the first centimeter of the GCV. Thorough mapping of the entire circumference of the GCV wall can help identify these epicardial gaps.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter , Vasos Coronários/anatomia & histologia , Etanol/administração & dosagem , Músculo Liso Vascular/anatomia & histologia , Veias/anatomia & histologia , Idoso , Mapeamento Epicárdico , Feminino , Bloqueio Cardíaco/etiologia , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Pericárdio/anatomia & histologia
8.
Europace ; 23(11): 1767-1776, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34240134

RESUMO

AIMS: Pulsed field ablation (PFA), a non-thermal ablative modality, may show different effects on the myocardial tissue compared to thermal ablation. Thus, this study aimed to compare the left atrial (LA) structural and mechanical characteristics after PFA vs. thermal ablation. METHODS AND RESULTS: Cardiac magnetic resonance was performed pre-ablation, acutely (<3 h), and 3 months post-ablation in 41 patients with paroxysmal atrial fibrillation (AF) undergoing pulmonary vein (PV) isolation with PFA (n = 18) or thermal ablation (n = 23, 16 radiofrequency ablations, 7 cryoablations). Late gadolinium enhancement (LGE), T2-weighted, and cine images were analysed. In the acute stage, LGE volume was 60% larger after PFA vs. thermal ablation (P < 0.001), and oedema on T2 imaging was 20% smaller (P = 0.002). Tissue changes were more homogeneous after PFA than after thermal ablation, with no sign of microvascular damage or intramural haemorrhage. In the chronic stage, the majority of acute LGE had disappeared after PFA, whereas most LGE persisted after thermal ablation. The maximum strain on PV antra, the LA expansion index, and LA active emptying fraction declined acutely after both PFA and thermal ablation but recovered at the chronic stage only with PFA. CONCLUSION: Pulsed field ablation induces large acute LGE without microvascular damage or intramural haemorrhage. Most LGE lesions disappear in the chronic stage, suggesting a specific reparative process involving less chronic fibrosis. This process may contribute to a preserved tissue compliance and LA reservoir and booster pump functions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Meios de Contraste , Fibrose , Gadolínio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética
9.
Pacing Clin Electrophysiol ; 44(6): 1075-1084, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33932234

RESUMO

BACKGROUND: Conventional bipolar electrodes (CBE) may be suboptimal to detect local abnormal ventricular activities (LAVAs). Microelectrodes (ME) may improve the detection of LAVAs. This study sought to elucidate the detectability of LAVAs using ME compared with CBE in patients with scar-related ventricular tachycardia (VT). METHODS: We included consecutive patients with structural heart disease who underwent radiofrequency catheter ablation for scar-related VT using either of the following catheters equipped with ME: QDOTTM or IntellaTip MIFITM. Detection field of LAVA potentials were classified as three types: Type 1 (both CBE and ME detected LAVA), Type 2 (CBE did not detect LAVA while ME did), and Type 3 (CBE detected LAVA while ME did not). RESULTS: In 16 patients (68 ± 16 years; 14 males), 260 LAVAs electrograms (QDOT = 72; MIFI = 188) were analyzed. Type 1, type 2, and type 3 detections were 70.8% (QDOT, 69.4%; MIFI, 71.3%), 20.0% (QDOT, 23.6%; MIFI, 18.6%) and 9.2% (QDOT, 6.9%; MIFI, 10.1%), respectively. The LAVAs amplitudes detected by ME were higher than those detected by CBE in both catheters (QDOT: ME 0.79 ± 0.50 mV vs. CBE 0.41 ± 0.42 mV, p = .001; MIFI: ME 0.73 ± 0.64 mV vs. CBE 0.38 ± 0.36 mV, p < .001). CONCLUSIONS: ME allow to identify 20% of LAVAs missed by CBE. ME showed higher amplitude LAVAs than CBE. However, 9.2% of LAVAs can still be missed by ME.


Assuntos
Cicatriz/fisiopatologia , Eletrodos Implantados , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Idoso , Ablação por Cateter , Feminino , Humanos , Masculino , Microeletrodos , Estudos Retrospectivos , Taquicardia Ventricular/cirurgia
10.
Circ Arrhythm Electrophysiol ; 13(12): e008884, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33197321

RESUMO

BACKGROUND: Achieving bidirectional mitral isthmus (MI) block using radiofrequency catheter ablation (RFCA) alone is challenging, and MI reconnection is common. Adjunctive vein of Marshall (VOM) ethanol infusion (VOM-Et) can facilitate acute MI block. However, little is known about its long-term success. This study sought to evaluate the impact of adjunctive VOM-Et on MI block achievement and durability compared with RFCA alone. METHODS: Patients undergoing the first attempt of posterior MI ablation were grouped according to their MI block index strategy: adjunctive VOM-Et and RFCA alone. Rates of acute MI block and MI reconnection observed during repeat procedures were compared between the 2 groups. RESULTS: The VOM-Et group consisted of 152 patients (63.8±9.4 years) undergoing adjunctive VOM-Et for MI block. The RFCA group consisted of 110 patients (60.9±9.2 years) undergoing MI ablation using RFCA alone. Acute MI block was more frequently achieved in the VOM-Et group (98.7% [150/152] versus 63.6% [70/110]; P<0.001) with shorter RFCA duration (5.00 [3.00-7.00] versus 19.0 [13.6-22.0] minutes; P<0.001). Of the 220 patients with MI block achieved during the index procedure, 81 underwent a repeat procedure during follow-up (VOM-Et group: 23.3% [35/150] versus RFCA group: 65.7% [46/70], respectively; P<0.001). A significantly greater number of patients exhibited durable MI block in the VOM-Et group (62.9% [22/35] versus 32.6% [15/46], respectively; P=0.008). CONCLUSIONS: Beyond facilitating acute MI block, VOM-Et is associated with greater lesion durability as evidenced by higher rates of MI block during repeat procedures.


Assuntos
Arritmias Cardíacas/cirurgia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Vasos Coronários/cirurgia , Etanol/administração & dosagem , Veias/cirurgia , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Etanol/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Veias/diagnóstico por imagem , Veias/fisiopatologia
12.
Presse Med ; 48(6): 604-608, 2019 Jun.
Artigo em Francês | MEDLINE | ID: mdl-31151844

RESUMO

The efficacy of implantable cardiac defibrillators for prevention of sudden cardiac death (SCD) has been well documented. However, morbidity and complications of these devices have been of major concern. The wearable cardiac defibrillator (WCD) provides an option for protection during this vulnerable period when the risk of SCD is unclear. The subcutaneous implantable cardiac defibrillator (S-ICD) may indeed offer a viable therapeutic option in selected patients at high risk of SCD and in whom pacing is not required. The S-ICD and the WCD represent a further step in evolution of defibrillator technology in the prevention of S-ICD.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Desenho de Equipamento , Humanos
14.
Int J Cardiol ; 243: 424-430, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28550978

RESUMO

BACKGROUND: Type 1 myotonic dystrophy (DM1) patients' prognosis is very poor. Up until now, only a few prognostic factors for cardiovascular events have been identified, and they are predictive of end-stage disease. The aim was to assess the prognostic value of global longitudinal strain (GLS) for cardiovascular events in asymptomatic DM1 patients. METHODS: DM1 patients were included between 2011 and 2015 and followed up until January 2016. Patients underwent a transthoracic echocardiography at inclusion. The primary endpoint was a composite of all-cause mortality, type 2 Mobitz 2 and type 3 atrioventricular block, symptomatic sino-atrial block, HV interval≥70ms at invasive electrophysiology exploration, left ventricular ejection fraction (LVEF) ≤45% and newly developed atrial fibrillation. RESULTS: Forty-six patients (25 males, mean age 40years old) were included. The primary outcome was reached in 14 patients with a mean follow-up of 38months. GLS of patients who reached the primary endpoint was significantly impaired as compared to those who did not (-15.1 [-16.7; -12.7] vs. -18.2 [-19.2; -16.7] respectively; P=0.001). According to ROC curve analysis, probability of primary outcome occurrence was significantly greater in patients with GLS values≥-17.2% (P=0.001). On multivariate analysis, PR electrocardiogram interval and GLS remained significantly and independently associated with the primary endpoint [hazard ratio (HR) 1.03, 95% confidence interval (CI) 1.01-1.04, P=0.006 for PR interval; HR 1.4, 95% CI 1.1-1.7, P=0.002 for GLS] while LVEF alone was not. CONCLUSION: Left ventricular GLS is a powerful marker to predict cardiovascular events in asymptomatic DM1 patients, independently of LVEF.


Assuntos
Doenças Assintomáticas/mortalidade , Distrofia Miotônica/diagnóstico por imagem , Distrofia Miotônica/mortalidade , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Adulto , Ecocardiografia/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Distrofia Miotônica/fisiopatologia , Valor Preditivo dos Testes , Taxa de Sobrevida/tendências , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...