1.
J AOAC Int ; 98(6): 1571-84, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26651570

RESUMO

The QuickTox Kit for QuickScan Aflatoxin FREE uses competitive lateral flow technology and a reader based system for quantitative determination of total aflatoxins in varied matrixes. Aqueous based extraction protocols are used for corn and wheat, reducing use of solvents. Fifty percent ethanol (Reagent Alcohol) extraction is used for oats, sorghum, and barley. Eighty percent ethanol (Reagent Alcohol) extraction is used for whole peanut, peanut seed, and peanut hull samples. Matrix specific assay procedures and calibration curves are used to enable analyses across multiple sample types. The performance of this assay was examined using naturally contaminated aflatoxin corn samples and spiked samples of barley, oats, sorghum, wheat, whole peanut, peanut seed, and peanut hull samples. All data were judged against previously established acceptance criteria. Performance was evaluated in linearity, selectivity, matrix, lot consistency, and robustness experiments in the sponsor's laboratory. Results produced in all studies except robustness were within acceptable ranges. Out of range robustness study results reflected simultaneous deviation in sample volume and assay development time compared to the standard assay procedures. Aflatoxin B1, B2, and G1 were detected with approximately equal sensitivity; sensitivity for G2 was 64% that of B1. The presence of other common mycotoxins did not interfere with the assay. Matrix studies in an independent laboratory examined corn and barley to challenge both aqueous and ethanol based extraction procedures. All data points in these studies fell within the ranges defined in the acceptance criteria. The assay exhibited a linear dose response over the range tested, 0-100 ppb, with R(2) values exceeding 0.93 and RSDr values for results ranging from 2.27 to 23.84%.


Assuntos
Aflatoxinas/análise , Contaminação de Alimentos/análise , Kit de Reagentes para Diagnóstico
2.
J AOAC Int ; 98(1): 85-93, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25857883

RESUMO

Lateral flow technology and a reader-based system are used for quantitative determination of deoxynivalenol (DON), also known as vomitoxin, residues in cereal grain commodities by the QuickTox Kit for QuickScan DON (Vomitoxin). The assay has been modified, and a study was conducted in support of a Performance Tested MethodSM (PTM) Modification. The modified assay employs identical biologic reagents as used previously (PTM No. 121202). Compared to the PTM certified product, the new assay uses modified device architecture. Multiple kits and catalog numbers were required in the original kit reflecting the necessity for matrix specific calibration curves affixed to assay strips. A single calibration curve and kit are utilized in the new product; extraction volumes used in sample preparation are varied to accommodate multiple sample types. Extracts are clarified by filtration or settling depending on the sample type. Filtration was used for matrixes examined in these studies. With the original product, the extract was mixed 1:1 with DB1 buffer followed by the addition of the strip which was developed for 10 min. The new product dilutes extracts five-fold offline in DB6 buffer; an aliquot of the dilution is moved to a reaction vial followed by strip development time for 3 min. The new assay performance was evaluated for linearity, robustness, selectivity (inclusivity), lot-to-lot consistency, and both internal and third party matrix studies. All DON positive samples yielded results within previously defined acceptable ranges with dose-dependent correlation values of R2 greater than 0.97 in linearity and internal and external matrix studies. Inclusivity data indicated detection of DON along with acetyl derivatives, glucoside-conjugate, and Nivalenol. Robustness studies showed within range results upon co-variation of multiple user interface parameters, and lot-to-lot consistency challenges demonstrated acceptable results across five manufactured lots.


Assuntos
Contaminação de Alimentos , Tricotecenos/química , Estabilidade de Medicamentos , Kit de Reagentes para Diagnóstico