Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mass Spectrom ; 49(9): 911-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25230188

RESUMO

To ensure that egg-containing products, such as dried eggs and egg pasta, conform to the technological and legislative requirements for egg content, methods are needed to determine the amount of cholesterol in such products. The conventional approach, direct saponification and hexane extraction followed by cholesterol determination by gas chromatography coupled to a flame ionization detector, is very time consuming. Therefore, we developed a rapid method on the basis of direct analysis in real time coupled to time-of-flight mass spectrometry. Samples were prepared simply by solvent extraction followed by extract filtration. The optimization of certain parameters, including the solvent used and direct analysis in real time ionization gas temperature, had a pronounced effect on the intensities of the produced ions, in particular, the molecular and dehydrated ions of cholesterol and its deuterated analog, cholesterol 2,2,3,4,4,6-d(6) which was used as an internal standard. For the developed method, limits of detection and quantification were 0.03 and 0.05 mg g(-1) respectively. The results of the real samples were compared with those obtained using the conventional approach [limit of detection = 0.002 mg g(-1) and limit of quantification = 0.05 mg g(-1)], and it was found that, although the results obtained using the conventional approach were more accurate, our developed method is much simpler and faster, where the time was dramatically reduced by 87% for executing a screening analysis.

2.
Anal Bioanal Chem ; 405(14): 4737-45, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23503749

RESUMO

DART (direct analysis in real time), a novel technique with wide potential for rapid screening analysis, coupled with high-resolution time-of-flight mass spectrometry (TOF-MS) has been used for quantitative analysis of 5-hydroxymethylfurfural (5-HMF), a typical temperature marker of food. The DART/TOF-MS method was optimised and validated. Quantification of 5-HMF was achieved by use of a stable isotope-labelled 5-HMF standard prepared from glucose. Formation of 5-HMF from saccharides, a potential source of overestimation of results, was evaluated. Forty-four real samples (honey and caramelised condensed sweetened milk) and 50 model samples of heated honey were analysed. The possibility of using DART for analysis of heated samples of honey was confirmed. HPLC and DART/TOF-MS methods for determination of 5-HMF were compared. The correlation equation between these methods was DART = 1.0287HPLC + 0.21340, R(2) = 0.9557. The DART/TOF-MS method has been proved to enable efficient and rapid determination of 5-HMF in a variety of food matrices, for example honey and caramel.


Assuntos
Furaldeído/análogos & derivados , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Sistemas Computacionais , Desenho de Equipamento , Análise de Falha de Equipamento , Furaldeído/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...