1.
Rev Sci Instrum ; 92(3): 034708, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820089

RESUMO

We present a cryogenic microwave noise source with a characteristic impedance of 50 Ω, which can be installed in a coaxial line of a cryostat. The bath temperature of the noise source is continuously variable between 0.1 K and 5 K without causing significant back-action heating on the sample space. As a proof-of-concept experiment, we perform Y-factor measurements of an amplifier cascade that includes a traveling wave parametric amplifier and a commercial high electron mobility transistor amplifier. We observe system noise temperatures as low as 680-200 +20 mK at 5.7 GHz corresponding to 1.5-0.7 +0.1 excess photons. The system we present has immediate applications in the validation of solid-state qubit readout lines.

2.
Sci Adv ; 6(15): eaax9191, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32300644

RESUMO

Electrothermal elements are used in various energy harvesters, coolers, and radiation detectors. The optimal operation of these elements relies on mastering two competing boundary conditions: the maximization of the electrothermal response and the blockade of lattice (phonon) thermal conduction. In this work, we propose and demonstrate that efficient electrothermal operation and phonon blocking can be achieved in solid-state thermionic junctions, paving the way for new phonon-engineered high-efficiency refrigerators and sensors. Our experimental demonstration uses semiconductor-superconductor (Sm-S) junctions where the electrothermal response arises from the superconducting energy gap and the phonon blocking results from the acoustic transmission bottleneck at the junction. We demonstrate a cooling platform where a silicon chip, suspended only from the Sm-S junctions, is cooled by ~40% from the bath temperature. We also show how the observed effect can be used in radiation detectors and multistage electronic refrigerators suitable for cooling of quantum technology devices.

3.
Rev Sci Instrum ; 90(7): 074702, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31370443

RESUMO

Kinetic inductance bolometer technology is a candidate for passive submillimeter wave and terahertz imaging systems. Its benefits include scalability into large 2D arrays and operation with intermediate cryogenics in the temperature range of 5-10 K. We have previously demonstrated the scalability in terms of device fabrication, optics integration, and cryogenics. In this article, we address the last missing ingredient, the readout. The concept, serial addressed frequency excitation, is an alternative to full frequency-division multiplexing at microwave frequencies conventionally used to read out kinetic inductance detectors. We introduce the concept and analyze the criteria of the multiplexed readout avoiding the degradation of the signal-to-noise ratio in the presence of a thermal anti-alias filter inherent to thermal detectors. We present a practical scalable realization of a readout system integrated into a prototype imager with 8712 detectors. This is used for demonstrating the noise properties of the readout. Furthermore, we present practical detection experiments with a stand-off laboratory-scale imager.

4.
Phys Rev Lett ; 122(8): 080503, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30932559

RESUMO

We theoretically propose and experimentally implement a method of measuring a qubit by driving it close to the frequency of a dispersively coupled bosonic mode. The separation of the bosonic states corresponding to different qubit states begins essentially immediately at maximum rate, leading to a speedup in the measurement protocol. Also the bosonic mode can be simultaneously driven to optimize measurement speed and fidelity. We experimentally test this measurement protocol using a superconducting qubit coupled to a resonator mode. For a certain measurement time, we observe that the conventional dispersive readout yields close to 100% higher average measurement error than our protocol. Finally, we use an additional resonator drive to leave the resonator state to vacuum if the qubit is in the ground state during the measurement protocol. This suggests that the proposed measurement technique may become useful in unconditionally resetting the resonator to a vacuum state after the measurement pulse.

5.
Nat Commun ; 5: 4872, 2014 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-25204869

RESUMO

Sensing ultra-low magnetic fields has various applications in the fields of science, medicine and industry. There is a growing need for a sensor that can be operated in ambient environments where magnetic shielding is limited or magnetic field manipulation is involved. To this end, here we demonstrate a new magnetometer with high sensitivity and wide dynamic range. The device is based on the current nonlinearity of superconducting material stemming from kinetic inductance. A further benefit of our approach is of extreme simplicity: the device is fabricated from a single layer of niobium nitride. Moreover, radio frequency multiplexing techniques can be applied, enabling the simultaneous readout of multiple sensors, for example, in biomagnetic measurements requiring data from large sensor arrays.

6.
Appl Opt ; 49(19): E106-20, 2010 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-20648113

RESUMO

We describe the construction and performance of a passive, real-time terahertz camera based on a modular, 64-element linear array of cryogenic hotspot microbolometers. A reflective conical scanner sweeps out a 2 m x 4 m (vertical x horizontal) field of view (FOV) at a standoff range of 8 m. The focal plane array is cooled to 4 K in a closed cycle refrigerator, and the signals are detected on free-standing bridges of superconducting Nb or NbN at the feeds of broadband planar spiral antennas. The NETD of the focal-plane array, referred to the target plane and to a frame rate of 5 s(-1), is 1.25 K near the center of the array and 2 K overall.